Literature DB >> 21129878

A general dual-bolus approach for quantitative DCE-MRI.

Lucy E Kershaw1, Hai-Ling Margaret Cheng.   

Abstract

PURPOSE: To present a dual-bolus technique for quantitative dynamic contrast-enhanced MRI (DCE-MRI) and show that it can give an arterial input function (AIF) measurement equivalent to that from a single-bolus protocol.
METHODS: Five rabbits were imaged using a dual-bolus technique applicable for high-resolution DCE-MRI, incorporating a time resolved imaging of contrast kinetics (TRICKS) sequence for rapid temporal sampling. AIFs were measured from both the low-dose prebolus and the high-dose main bolus in the abdominal aorta. In one animal, TRICKS and fast spoiled gradient echo (FSPGR) acquisitions were compared.
RESULTS: The scaled prebolus AIF was shown to match the main bolus AIF, with 95% confidence intervals overlapping for fits of gamma-variate functions to the first pass and linear fits to the washout phase, with the exception of one case. The AIFs measured using TRICKS and FSPGR were shown to be equivalent in one animal.
CONCLUSION: The proposed technique can capture even the rapid circulation kinetics in the rabbit aorta, and the scaled prebolus AIF is equivalent to the AIF from a high-dose injection. This allows separate measurements of the AIF and tissue uptake curves, meaning that each curve can then be acquired using a protocol tailored to its specific requirements.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21129878     DOI: 10.1016/j.mri.2010.08.009

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  17 in total

1.  Robust quantification of microvascular transit times via linear dynamical systems using two-photon fluorescence microscopy data.

Authors:  Lakshminarayan V Chinta; Liis Lindvere; Bojana Stefanovic
Journal:  J Cereb Blood Flow Metab       Date:  2012-06-20       Impact factor: 6.200

2.  A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings.

Authors:  Luminita A Tudorica; Karen Y Oh; Nicole Roy; Mark D Kettler; Yiyi Chen; Stephanie L Hemmingson; Aneela Afzal; John W Grinstead; Gerhard Laub; Xin Li; Wei Huang
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

3.  Dynamic field-of-view imaging to increase temporal resolution in the early phase of contrast media uptake in breast DCE-MRI: A feasibility study.

Authors:  Federico D Pineda; Ty O Easley; Gregory S Karczmar
Journal:  Med Phys       Date:  2018-01-24       Impact factor: 4.071

4.  Imaging the efficacy of anti-inflammatory liposomes in a rabbit model of atherosclerosis by non-invasive imaging.

Authors:  Mark E Lobatto; Claudia Calcagno; Josbert M Metselaar; Gert Storm; Erik S G Stroes; Zahi A Fayad; Willem J M Mulder
Journal:  Methods Enzymol       Date:  2012       Impact factor: 1.600

5.  DCE-MRI of the liver: effect of linear and nonlinear conversions on hepatic perfusion quantification and reproducibility.

Authors:  Shimon Aronhime; Claudia Calcagno; Guido H Jajamovich; Hadrien Arezki Dyvorne; Philip Robson; Douglas Dieterich; M Isabel Fiel; Valérie Martel-Laferriere; Manjil Chatterji; Henry Rusinek; Bachir Taouli
Journal:  J Magn Reson Imaging       Date:  2013-11-04       Impact factor: 4.813

6.  Effects of voluntary exercise on structure and function of cortical microvasculature.

Authors:  Adrienne Dorr; Lynsie Am Thomason; Margaret M Koletar; Illsung L Joo; Joe Steinman; Lindsay S Cahill; John G Sled; Bojana Stefanovic
Journal:  J Cereb Blood Flow Metab       Date:  2016-10-01       Impact factor: 6.200

7.  Arterial input functions (AIFs) measured directly from arteries with low and standard doses of contrast agent, and AIFs derived from reference tissues.

Authors:  Shiyang Wang; Xiaobing Fan; Milica Medved; Federico D Pineda; Ambereen Yousuf; Aytekin Oto; Gregory S Karczmar
Journal:  Magn Reson Imaging       Date:  2015-10-30       Impact factor: 2.546

8.  Ultrafast Bilateral DCE-MRI of the Breast with Conventional Fourier Sampling: Preliminary Evaluation of Semi-quantitative Analysis.

Authors:  Federico D Pineda; Milica Medved; Shiyang Wang; Xiaobing Fan; David V Schacht; Charlene Sennett; Aytekin Oto; Gillian M Newstead; Hiroyuki Abe; Gregory S Karczmar
Journal:  Acad Radiol       Date:  2016-06-06       Impact factor: 3.173

9.  Interstudy repeatability of self-gated quantitative myocardial perfusion MRI.

Authors:  Devavrat Likhite; Promporn Suksaranjit; Ganesh Adluru; Nan Hu; Cindy Weng; Eugene Kholmovski; Chris McGann; Brent Wilson; Edward DiBella
Journal:  J Magn Reson Imaging       Date:  2015-12-13       Impact factor: 4.813

10.  SHILO, a novel dual imaging approach for simultaneous HI-/LOw temporal (Low-/Hi-spatial) resolution imaging for vascular dynamic contrast enhanced cardiovascular magnetic resonance: numerical simulations and feasibility in the carotid arteries.

Authors:  Claudia Calcagno; Philip M Robson; Sarayu Ramachandran; Venkatesh Mani; Melanie Kotys-Traughber; Matthew Cham; Stefan E Fischer; Zahi A Fayad
Journal:  J Cardiovasc Magn Reson       Date:  2013-05-24       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.