Literature DB >> 29314060

Dynamic field-of-view imaging to increase temporal resolution in the early phase of contrast media uptake in breast DCE-MRI: A feasibility study.

Federico D Pineda1, Ty O Easley1, Gregory S Karczmar1.   

Abstract

PURPOSE: To increase diagnostic accuracy of breast MRI by increasing temporal resolution and more accurately sampling the early kinetics of contrast media uptake. We tested the feasibility of accelerating bilateral breast DCE-MRI by reducing the FOV, allowing aliasing, and unfolding the resulting images.
METHODS: Previous experience with an "ultrafast" protocol for bilateral breast DCE-MRI (6-10 s temporal resolution) showed that the number of significantly enhancing voxels is very low in the first 30-45 s after contrast media injection. This suggests that overlap of enhancing voxels in aliased images will be very infrequent. Therefore, aliased images can be acquired during the first 30-45 s after contrast media injection and unfolded to produce full-FOV images with few errors. In a proof-of-principle test, aliased images were simulated from the first 30 s of full-FOV acquisitions. Cases with relatively dense early enhancement were selected to test this method in a worst-case scenario. In an initial test, an FOV of 60% the size of the full FOV was simulated. To reduce the probability of errors due to overlapping voxels in aliased images, we then tested a dynamic FOV approach. The FOV was progressively increased so that enhancing voxels could not overlap at multiple time-points, and areas where enhancing voxels overlapped at a given time-point could be unfolded by interpolating between the preceding and subsequent time-points (acquired with different FOVs). The simulated FOV sizes for each of the time-points were 31%, 44%, and 77% of the full FOV. Subtraction images (post- minus precontrast) were generated for aliased images and filtered to select significantly enhancing voxels. Comparison of early, highly aliased images, with later, less aliased images then helped to identify the true locations of enhancing voxels.
RESULTS: In the initial aliasing simulations, an average of 2.9% of the enhancing voxels above the chest wall overlapped in the aliased images (range 0.1%-6.7%). The similarity between simulated unfolded images and the correct full-FOV images, evaluated using CW-SSIM (complex wavelet similarity index), was 0.50 ± 0.26, 0.76 ± 0.09, and 0.80 ± 0.10 for the first, second, and third time-point, respectively (numbers closer to 1 indicate more similar images). For the dynamic FOV tests, an average of 11% of the enhancing voxels above the chest wall overlapped (range 0%-40%) due to greater aliasing at early time-points. Despite more voxels overlapping, the CW-SSIM values for the data acquired with dynamic FOVs were 0.64 ± 0.25, 0.93 ± 0.04, and 0.97 ± 0.02 for the first, second, and third time-points, respectively.
CONCLUSIONS: Dynamic FOV imaging allows accelerated bilateral breast DCE-MRI during the early contrast media uptake phase. This method relies on the sparsity of enhancement at the early phases of DCE-MRI of the breast. The results of simulations suggest that dynamic FOV imaging and unfolding produces images that are very close to fully sampled images, and allows temporal resolution as high as 2 s per image.
© 2018 American Association of Physicists in Medicine.

Entities:  

Keywords:  DCE-MRI; breast imaging; high temporal resolution MRI; reduced FOV imaging

Mesh:

Substances:

Year:  2018        PMID: 29314060      PMCID: PMC6028013          DOI: 10.1002/mp.12747

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  32 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

3.  A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings.

Authors:  Luminita A Tudorica; Karen Y Oh; Nicole Roy; Mark D Kettler; Yiyi Chen; Stephanie L Hemmingson; Aneela Afzal; John W Grinstead; Gerhard Laub; Xin Li; Wei Huang
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

4.  Reconstruction of 3D dynamic contrast-enhanced magnetic resonance imaging using nonlocal means.

Authors:  Ganesh Adluru; Tolga Tasdizen; Matthias C Schabel; Edward V R DiBella
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

5.  Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging.

Authors:  Felix A Breuer; Martin Blaimer; Robin M Heidemann; Matthias F Mueller; Mark A Griswold; Peter M Jakob
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

6.  Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data.

Authors:  Thomas E Yankeelov; Greg O Cron; Christina L Addison; Julia C Wallace; Ruth C Wilkins; Bruce A Pappas; Giles E Santyr; John C Gore
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

7.  Complex wavelet structural similarity: a new image similarity index.

Authors:  Mehul P Sampat; Zhou Wang; Shalini Gupta; Alan Conrad Bovik; Mia K Markey
Journal:  IEEE Trans Image Process       Date:  2009-06-23       Impact factor: 10.856

8.  Comparison of conventional DCE-MRI and a novel golden-angle radial multicoil compressed sensing method for the evaluation of breast lesion conspicuity.

Authors:  Laura Heacock; Yiming Gao; Samantha L Heller; Amy N Melsaether; James S Babb; Tobias K Block; Ricardo Otazo; Sungheon G Kim; Linda Moy
Journal:  J Magn Reson Imaging       Date:  2016-11-17       Impact factor: 4.813

9.  Reconstruction of dynamic contrast enhanced magnetic resonance imaging of the breast with temporal constraints.

Authors:  Liyong Chen; Matthias C Schabel; Edward V R DiBella
Journal:  Magn Reson Imaging       Date:  2010-04-13       Impact factor: 2.546

10.  Temporal sampling requirements for the tracer kinetics modeling of breast disease.

Authors:  E Henderson; B K Rutt; T Y Lee
Journal:  Magn Reson Imaging       Date:  1998-11       Impact factor: 2.546

View more
  1 in total

1.  Research on DCE-MRI Images Based on Deep Transfer Learning in Breast Cancer Adjuvant Curative Effect Prediction.

Authors:  Guolin Ye; Suqun He; Ruilin Pan; Lewei Zhu; Dan Zhou; RuiLiang Lu
Journal:  J Healthc Eng       Date:  2022-02-23       Impact factor: 2.682

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.