Literature DB >> 21111313

Partial coherence interferometry versus immersion ultrasonography for axial length measurement in children.

Phoebe D Lenhart1, Amy K Hutchinson, Michael J Lynn, Scott R Lambert.   

Abstract

PURPOSE: To determine whether measurements obtained by partial coherence interferometry (PCI) correlate well with measurements obtained using immersion ultrasound (US) in children.
SETTING: Department of Ophthalmology, Emory University School of Medicine, Atlanta, Georgia, USA.
DESIGN: Evaluation of a diagnostic test or technology.
METHODS: The charts of pediatric patients who had cataract surgery from August 2008 to September 2009 were reviewed. Axial length (AL) measurements in the operative eye were obtained using PCI at the preoperative clinic visit and then using immersion US in the operating room before surgery. The data were compared to determine the degree of agreement.
RESULTS: The charts of 18 patients (27 eyes) were reviewed. Preoperative AL measurements by PCI were obtained in 21 eyes (78%). On average, the PCI-measured ALs were 0.1 mm less than the immersion US values (95% confidence interval, -0.2 to -0.1; P = .002). All eyes with an AL of 23.5 mm or less had lower PCI values than immersion US values. There was no systematic pattern of 1 measurement being greater or less than the other in eyes with an AL longer than 23.5 mm.
CONCLUSIONS: There was a systematic difference in AL measurement between PCI and immersion US, with PCI tending to give lower values, particularly in eyes with an AL of 23.5 mm or less. Depending on the length of the eye, a 0.1 mm error in AL measurement could result in a 0.25 to 0.75 diopter difference in intraocular lens calculation that could be clinically significant in some patients.
Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21111313      PMCID: PMC2991047          DOI: 10.1016/j.jcrs.2010.07.013

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  13 in total

1.  Highly precise eye length measurements in children aged 3 through 12 years.

Authors:  Graham E Quinn; Ellie L Francis; Karen S Nipper; D Ian Flitcroft; Gui-shuang Ying; Renee C Rees; Gregor F Schmid; Maureen G Maguire; Richard A Stone
Journal:  Arch Ophthalmol       Date:  2003-07

2.  Reliability and validity of the partial coherence interferometry for measurement of ocular axial length in children.

Authors:  H M Hussin; P G D Spry; M A Majid; P Gouws
Journal:  Eye (Lond)       Date:  2005-08-12       Impact factor: 3.775

3.  Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.

Authors:  Thomas Olsen
Journal:  Acta Ophthalmol Scand       Date:  2007-02

4.  Immersion A-scan compared with partial coherence interferometry: outcomes analysis.

Authors:  Mark Packer; I Howard Fine; Richard S Hoffman; Peggy G Coffman; Laurie K Brown
Journal:  J Cataract Refract Surg       Date:  2002-02       Impact factor: 3.351

5.  Improving the predictability of intraocular lens power calculations.

Authors:  J T Holladay; T C Prager; R S Ruiz; J W Lewis; H Rosenthal
Journal:  Arch Ophthalmol       Date:  1986-04

6.  Effect of age at time of cataract surgery on subsequent axial length growth in infant eyes.

Authors:  E D Griener; E Dahan; S R Lambert
Journal:  J Cataract Refract Surg       Date:  1999-09       Impact factor: 3.351

7.  Comparison of refractive outcomes using immersion ultrasound biometry and IOLMaster biometry.

Authors:  John Landers; Michael Goggin
Journal:  Clin Exp Ophthalmol       Date:  2009-08       Impact factor: 4.207

8.  Refractive development of the human eye.

Authors:  R A Gordon; P B Donzis
Journal:  Arch Ophthalmol       Date:  1985-06

9.  Optical and ultrasound measurement of axial length and anterior chamber depth for intraocular lens power calculation.

Authors:  János Németh; Orsolya Fekete; Norbert Pesztenlehrer
Journal:  J Cataract Refract Surg       Date:  2003-01       Impact factor: 3.351

10.  Comparing immersion ultrasound with partial coherence interferometry for intraocular lens power calculation.

Authors:  Julio Narváez; D Hunter Cherwek; R Doyle Stulting; Rhonda Waldron; Grenith J Zimmerman; Izak F Wessels; George O Waring
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2008 Jan-Feb
View more
  5 in total

1.  A Model to Predict Postoperative Axial Length in Children Undergoing Bilateral Cataract Surgery With Primary Intraocular Lens Implantation.

Authors:  Rupal H Trivedi; Eliza Barnwell; Bethany Wolf; M Edward Wilson
Journal:  Am J Ophthalmol       Date:  2019-05-10       Impact factor: 5.258

2.  Comparison of intraocular lens power prediction using immersion ultrasound and optical biometry with and without formula optimization.

Authors:  Gabor Nemeth; Attila Nagy; Andras Berta; Laszlo Modis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-04-13       Impact factor: 3.117

3.  Axial length measurement techniques in pediatric eyes with cataract.

Authors:  M Edward Wilson; Rupal H Trivedi
Journal:  Saudi J Ophthalmol       Date:  2012-01

Review 4.  Updates on managements of pediatric cataract.

Authors:  Mehrdad Mohammadpour; Amirreza Shaabani; Alireza Sahraian; Bita Momenaei; Fereshteh Tayebi; Reza Bayat; Reza Mirshahi
Journal:  J Curr Ophthalmol       Date:  2018-12-22

5.  Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer.

Authors:  Bao Shu; Fangjun Bao; Giacomo Savini; Weicong Lu; Ruixue Tu; Haisi Chen; Benhao Song; Qinmei Wang; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2020-03-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.