Literature DB >> 21107983

Proximal tibial fractures: early experience using polyaxial locking-plate technology.

Vassilios S Nikolaou1, Hiang Boon Tan, George Haidukewych, Nikolaos Kanakaris, Peter V Giannoudis.   

Abstract

Between 2004 and 2009, 60 patients with proximal tibial fractures were included in this prospective study. All fractures were treated with the polyaxial locked-plate fixation system (DePuy, Warsaw, IN, USA). Clinical and radiographic data, including fracture pattern, changes in alignment, local and systemic complications, hardware failure and fracture union were analysed. The mean follow-up was 14 (12-36) months. According to the Orthopaedic Trauma Association (OTA) classification, there were five 41-A, 28 41-B and 27 41-C fractures. Fractures were treated percutaneously in 30% of cases. Double-plating was used in 11 cases. All but three fractures progressed to union at a mean of 3.2 (2.5-5) months. There was no evidence of varus collapse as a result of polyaxial screw failure. No plate fractured, and no screw cut out was noted. There was one case of lateral joint collapse (>10°) in a patient with open bicondylar plateau fracture. The mean Knee Society Score at the time of final follow-up was 91 points, and the mean functional score was 89 points. The polyaxial locking-plate system provided stable fixation of extra-articular and intra-articular proximal tibial fractures and good functional outcomes with a low complication rate.

Entities:  

Mesh:

Year:  2010        PMID: 21107983      PMCID: PMC3167437          DOI: 10.1007/s00264-010-1153-y

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  Tibial plateau fractures: functional outcome and incidence of osteoarthritis in 125 cases.

Authors:  Nikolaos Manidakis; Anis Dosani; Rozalia Dimitriou; Dirk Stengel; Stuart Matthews; Peter Giannoudis
Journal:  Int Orthop       Date:  2009-05-14       Impact factor: 3.075

2.  Single lateral locked screw plating of bicondylar tibial plateau fractures.

Authors:  T Gosling; P Schandelmaier; M Muller; S Hankemeier; M Wagner; C Krettek
Journal:  Clin Orthop Relat Res       Date:  2005-10       Impact factor: 4.176

3.  Immediate internal fixation of open, complex tibial plateau fractures: treatment by a standard protocol.

Authors:  S K Benirschke; S G Agnew; K A Mayo; V M Santoro; M B Henley
Journal:  J Orthop Trauma       Date:  1992       Impact factor: 2.512

4.  Fracture healing in biological plate osteosynthesis.

Authors:  F Baumgaertel; M Buhl; B A Rahn
Journal:  Injury       Date:  1998       Impact factor: 2.586

5.  Three-year results of proximal tibia fractures treated with the LISS.

Authors:  Christian Boldin; Florian Fankhauser; Herwig Peter Hofer; Rudolf Szyszkowitz
Journal:  Clin Orthop Relat Res       Date:  2006-04       Impact factor: 4.176

6.  Combined arthroscopic and radioscopic management of tibial plateau fractures: report of 18 clinical cases.

Authors:  Francesco Pogliacomi; Michele Arcangelo Verdano; Marco Frattini; Cosimo Costantino; Enrico Vaienti; Giovanni Soncini
Journal:  Acta Biomed       Date:  2005-09

7.  Complications of locking plate fixation in complex proximal tibia injuries.

Authors:  Phinit Phisitkul; Todd O McKinley; James V Nepola; John L Marsh
Journal:  J Orthop Trauma       Date:  2007-02       Impact factor: 2.512

8.  Results of polyaxial locked-plate fixation of periarticular fractures of the knee.

Authors:  George Haidukewych; Stephen A Sems; David Huebner; Daniel Horwitz; Bruce Levy
Journal:  J Bone Joint Surg Am       Date:  2007-03       Impact factor: 5.284

9.  Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques.

Authors:  Eric Fulkerson; Kenneth A Egol; Erik N Kubiak; Frank Liporace; Frederick J Kummer; Kenneth J Koval
Journal:  J Trauma       Date:  2006-04

10.  Locking plate technology: current concepts.

Authors:  R Michael Greiwe; Michael T Archdeacon
Journal:  J Knee Surg       Date:  2007-01       Impact factor: 2.757

View more
  10 in total

1.  Locking versus non-locking neutralization plates for treatment of lateral malleolar fractures: a randomized controlled trial.

Authors:  Sachiyuki Tsukada; Masaki Otsuji; Akira Shiozaki; Asako Yamamoto; Shuro Komatsu; Hideya Yoshimura; Hiroo Ikeda; Akiho Hoshino
Journal:  Int Orthop       Date:  2013-12       Impact factor: 3.075

Review 2.  Outcomes following the treatment of bicondylar tibial plateau fractures with fine wire circular frame external fixation compared to open reduction and internal fixation: A systematic review.

Authors:  Tarek Boutefnouchet; Ayaz S Lakdawala; Panayiotis Makrides
Journal:  J Orthop       Date:  2015-02-24

3.  History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

Authors:  Philippe Hernigou; Jacques Pariat
Journal:  Int Orthop       Date:  2016-12-30       Impact factor: 3.075

4.  Multi-plate reconstruction for severe bicondylar tibial plateau fractures of young adults.

Authors:  Qilin Zhai; Chengfang Hu; Congfeng Luo
Journal:  Int Orthop       Date:  2013-12-18       Impact factor: 3.075

5.  Lateral Locked Plating or Dual Plating: A Comparison of Two Methods in Simple Bicondylar Tibial Plateau Fractures.

Authors:  Caner Citak; Cemil Kayali; Firat Ozan; Taskin Altay; Huseyin Gokhan Karahan; Kamil Yamak
Journal:  Clin Orthop Surg       Date:  2019-05-09

6.  Prevalence of Deep Surgical Site Infection After Repair of Periarticular Knee Fractures: A Systematic Review and Meta-analysis.

Authors:  Grayson R Norris; Jake X Checketts; Jared T Scott; Matt Vassar; Brent L Norris; Peter V Giannoudis
Journal:  JAMA Netw Open       Date:  2019-08-02

Review 7.  A Meta-analysis Comparing External Fixation against Open Reduction and Internal Fixation for the Management of Tibial Plateau Fractures.

Authors:  Ahmad S Naja; Nour Bouji; Mohamad Nasser Eddine; Humaid Alfarii; Rudolf Reindl; Yehia Tfayli; Mohamad Issa; Said Saghieh
Journal:  Strategies Trauma Limb Reconstr       Date:  2022 May-Aug

8.  Stability of internal fixation systems based on different subtypes of Schatzker II fracture of the tibial plateau: A finite element analysis.

Authors:  Chuyang Zeng; Xiaomeng Ren; Cheng Xu; Mengmeng Hu; Jiantao Li; Wei Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-09-07

9.  Comparison of functional outcomes of tibial plateau fractures treated with nonlocking and locking plate fixations: a nonrandomized clinical trial.

Authors:  Mohammad Ali Tahririan; Seyyed Hamid Mousavitadi; Mohsen Derakhshan
Journal:  ISRN Orthop       Date:  2014-03-16

10.  Outcome of angular stable locking plate fixation of tibial plateau fractures Midterm results in 101 patients.

Authors:  Sven Märdian; Felix Landmann; Florian Wichlas; Norbert P Haas; Klaus-Dieter Schaser; Philipp Schwabe
Journal:  Indian J Orthop       Date:  2015 Nov-Dec       Impact factor: 1.251

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.