Literature DB >> 16456310

Three-year results of proximal tibia fractures treated with the LISS.

Christian Boldin1, Florian Fankhauser, Herwig Peter Hofer, Rudolf Szyszkowitz.   

Abstract

UNLABELLED: Proximal tibia fractures present a difficult treatment challenge with historically high complication rates. In a prospective study, we asked whether the Less Invasive Stabilization System (LISS) plate can adequately treat extraarticular and complex intraarticular proximal tibia fractures and provide low complication rates and acceptable long-term functional outcomes. We prospectively observed 25 patients with 26 proximal tibia fractures (AO type A2, A3, C1, C2, or C3) treated with the LISS. Consecutive 3-year followup included radiographs and clinical examinations using Knee Society scores and Hospital for Special Surgery scores for extraarticular and intraarticular fractures. No loss of reduction occurred in patients with extraarticular fractures, whereas varus malalignment occurred in one patient with an intraarticular fracture. Two patients with AO 41 C 3.3 fractures had severe knee arthrosis develop and had total knee replacements. The mean Knee Society scores and final average Hospital for Special Surgery scores were similar for extraarticular and intraarticular fractures. Complications related to the surgery included one delayed union and implant removal in two patients. The LISS provided stable fixation of extraarticular and intraarticular proximal tibia fractures and good functional outcomes with a low complication rate. In complex articular fractures additional screws should be used. LEVEL OF EVIDENCE: Therapeutic study, Level II (lesser quality randomized controlled trial [eg, < 80% followup, no blinding, or improper randomization]).

Entities:  

Mesh:

Year:  2006        PMID: 16456310     DOI: 10.1097/01.blo.0000203467.58431.a0

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  14 in total

1.  Comparison of the pre-shaped anatomical locking plate of 3.5 mm versus 4.5 mm for the treatment of tibial plateau fractures.

Authors:  Matthieu Ehlinger; Benjamin Adamczewski; Michel Rahmé; Philippe Adam; Francois Bonnomet
Journal:  Int Orthop       Date:  2015-03-08       Impact factor: 3.075

2.  Minimally invasive and open surgical treatment of proximal tibia fractures using a polyaxial locking plate system: a prospective multi-centre study.

Authors:  Jens A Jöckel; Johannes Erhardt; Miscia Vincenti; Jörg Reissig; Reinhard Hoffmann; Baher Husain; Gert Täger; Axel Partenheimer; Helmut Lill; Florian Gebhard; Götz Röderer
Journal:  Int Orthop       Date:  2013-02-16       Impact factor: 3.075

3.  Management of the Schatzker VI fractures with lateral locked screw plating.

Authors:  Rosario Spagnolo; Fabrizio Pace
Journal:  Musculoskelet Surg       Date:  2011-11-27

4.  Locked compression plating for peri- and intra-articular fractures around the knee.

Authors:  Jitesh Kumar Jain; Naiyer Asif; Suhail Ahmad; Owais Qureshi; Yasir Salam Siddiqui; Ashish Rana
Journal:  Orthop Surg       Date:  2013-11       Impact factor: 2.071

5.  Less invasive stabilization system for the management of proximal tibia fractures.

Authors:  Pramod Devkota; Hemanta K Manandhar; Padam B Khadka; Laxmi P Mainali; Javed A Khan; Balakrishnan M Acharya; Nabeesman S Pradhan; Suman K Shrestha
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

6.  Tibial fracture treated by minimally invasive plating using a novel low-cost, high-technique system.

Authors:  Bing Yin; Wei Chen; Qi Zhang; Juan Wang; Yanling Su; Guohui Xu; Yingze Zhang
Journal:  Int Orthop       Date:  2012-05-03       Impact factor: 3.075

Review 7.  [Extra-articular proximal tibial fracture].

Authors:  G Konrad; N Südkamp
Journal:  Chirurg       Date:  2007-02       Impact factor: 0.955

8.  Proximal tibial fractures: early experience using polyaxial locking-plate technology.

Authors:  Vassilios S Nikolaou; Hiang Boon Tan; George Haidukewych; Nikolaos Kanakaris; Peter V Giannoudis
Journal:  Int Orthop       Date:  2010-11-25       Impact factor: 3.075

9.  [Treatment of complicated proximal segmental tibia fractures with the less invasive stabilization locking plate system].

Authors:  M Beck; G Gradl; P Gierer; R Rotter; M Witt; T Mittlmeier
Journal:  Unfallchirurg       Date:  2008-07       Impact factor: 1.000

Review 10.  Intramedullary Nailing Versus Plating for Proximal Tibia Fractures: A Systematic Review and Meta-analysis.

Authors:  Karan Jindal; Deepak Neradi; Praveen Sodavarapu; Deepak Kumar; Akshay Shetty; Vijay Goni
Journal:  Indian J Orthop       Date:  2020-11-21       Impact factor: 1.251

View more