Literature DB >> 17332111

Results of polyaxial locked-plate fixation of periarticular fractures of the knee.

George Haidukewych1, Stephen A Sems, David Huebner, Daniel Horwitz, Bruce Levy.   

Abstract

BACKGROUND: Locked-plate fracture-fixation techniques and designs continue to evolve. Polyaxial locking plates that allow screw angulation and end-point locking have become available; however, there are no clinical data documenting their strength and efficacy, to our knowledge. The purpose of this study was to evaluate the clinical performance of a variable-axis locking plate in a multicenter series of periarticular fractures about the knee.
METHODS: Between 2003 and 2005, fifty-four patients with a total of fifty-six fractures were treated with a polyaxial locked-plate fixation system (DePuy, Warsaw, Indiana). There were twenty male patients and thirty-four female patients with a mean age of fifty-seven years. There were twenty-five distal femoral fractures and thirty-one proximal tibial fractures. Twelve of the fractures were open. Clinical and radiographic data, including changes in alignment, hardware breakage, or other mechanical complications of the device, were retrospectively reviewed. Function was assessed with use of the Knee Society scores. One patient with a bilateral fracture died less than three months postoperatively, and two patients were lost to follow-up prior to union. Fifty-two fractures in fifty-one patients were followed to union or for a minimum of six months; the mean duration of follow-up was nine months (range, six to twenty-five months).
RESULTS: Forty-nine (94%) of the fifty-two fractures united. There were no mechanical complications. Most importantly, there was no evidence of varus collapse as a result of polyaxial screw failure. There were three deep infections and one aseptic nonunion. No plate fractured, and no screw cut out.
CONCLUSIONS: The variable-axis locking plates performed well, with a high rate of fracture union and no evidence of varus collapse due to failure of the polyaxial screw fixation, in a series of complex fractures about the knee. Complication rates were similar to those for historical controls treated with fixed-trajectory locking plates. Polyaxial locking plates offer more fixation versatility without an apparent increase in mechanical complications or loss of reduction.

Entities:  

Mesh:

Year:  2007        PMID: 17332111     DOI: 10.2106/JBJS.F.00510

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  16 in total

1.  Staged protocol for initial management of the dislocated knee.

Authors:  Bruce A Levy; Aaron J Krych; Jay P Shah; Joseph A Morgan; Michael J Stuart
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-16       Impact factor: 4.342

2.  Implant material and design alter construct stiffness in distal femur locking plate fixation: a pilot study.

Authors:  Ulf Schmidt; Rainer Penzkofer; Samuel Bachmaier; Peter Augat
Journal:  Clin Orthop Relat Res       Date:  2013-09       Impact factor: 4.176

3.  Outcomes of distal femur fractures treated with the Synthes 4.5 mm VA-LCP Curved Condylar Plate.

Authors:  Khang H Dang; Connor A Armstrong; Ravi A Karia; Boris A Zelle
Journal:  Int Orthop       Date:  2018-09-29       Impact factor: 3.075

4.  The antegrade angle-stable locking intramedullary nail for type-C distal femoral fractures: a thirty four case experience.

Authors:  Zhihui Zhao; Yi Li; Kifayat Ullah; Basanta Sapkota; Hongbin Bi; Yongqing Wang
Journal:  Int Orthop       Date:  2018-02-03       Impact factor: 3.075

5.  Locked compression plating for peri- and intra-articular fractures around the knee.

Authors:  Jitesh Kumar Jain; Naiyer Asif; Suhail Ahmad; Owais Qureshi; Yasir Salam Siddiqui; Ashish Rana
Journal:  Orthop Surg       Date:  2013-11       Impact factor: 2.071

6.  Mortality after distal femur fractures in elderly patients.

Authors:  Philipp N Streubel; William M Ricci; Ambrose Wong; Michael J Gardner
Journal:  Clin Orthop Relat Res       Date:  2010-09-10       Impact factor: 4.176

7.  Proximal tibial fractures: early experience using polyaxial locking-plate technology.

Authors:  Vassilios S Nikolaou; Hiang Boon Tan; George Haidukewych; Nikolaos Kanakaris; Peter V Giannoudis
Journal:  Int Orthop       Date:  2010-11-25       Impact factor: 3.075

8.  [Treatment of complicated proximal segmental tibia fractures with the less invasive stabilization locking plate system].

Authors:  M Beck; G Gradl; P Gierer; R Rotter; M Witt; T Mittlmeier
Journal:  Unfallchirurg       Date:  2008-07       Impact factor: 1.000

9.  Fractures of the distal tibia treated with polyaxial locking plating.

Authors:  Hong Gao; Chang-Qing Zhang; Cong-Feng Luo; Zu-Bin Zhou; Bing-Fang Zeng
Journal:  Clin Orthop Relat Res       Date:  2008-08-22       Impact factor: 4.176

10.  Does prior infection alter the outcome of TKA after tibial plateau fracture?

Authors:  A Noelle Larson; Arlen D Hanssen; Joseph R Cass
Journal:  Clin Orthop Relat Res       Date:  2008-11-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.