Literature DB >> 21097990

A rotating bluff-body disc for reduced variability in wind tunnel aerosol studies.

Kirsten A Koehler1, T Renee Anthony, Michael van Dyke, John Volckens.   

Abstract

A rotating bluff-body disc (RBD) was developed to reduce spatiotemporal variability associated with sampling supermicron aerosol in low-velocity wind tunnels. The RBD is designed to rotate eight personal aerosol samplers around a circular path in a forward-facing plane aligned with the wind tunnel cross section. Rotation of the RBD allows each sampler to traverse an identical path about the wind tunnel cross section, which reduces the effects of spatial heterogeneity associated with dispersing supermicron aerosol in low-velocity wind tunnels. Samplers are positioned on the face of the RBD via sampling ports, which connect to an air manifold on the back of the disc. Flow through each sampler was controlled with a critical orifice or needle valve, allowing air to be drawn through the manifold with a single pump. A metal tube, attached to this manifold, serves as both the axis of rotation and the flow conduction path (between the samplers and the vacuum source). Validation of the RBD was performed with isokinetic samplers and 37-mm cassettes. For facing-the-wind tests, the rotation of the RBD significantly decreased intra-sampler variability when challenged with particle diameters from 1 to 100 μm. The RBD was then employed to determine the aspiration efficiency of Institute of Occupational Medicine (IOM) personal samplers under a facing-the-wind condition. Operation of IOM samplers on the RBD reduced the between-sampler variability for all particle sizes tested.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21097990      PMCID: PMC4780254          DOI: 10.1093/annhyg/meq078

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  7 in total

1.  Evaluation of six inhalable aerosol samplers.

Authors:  S N Li; D A Lundgren; D Rovell-Rixx
Journal:  AIHAJ       Date:  2000 Jul-Aug

2.  Performance testing of three portable, direct-reading dust monitors.

Authors:  A Thorpe; P T Walsh
Journal:  Ann Occup Hyg       Date:  2002-03

3.  The orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies.

Authors:  Samuel Y Paik; James H Vincent
Journal:  Ann Occup Hyg       Date:  2004-01

4.  Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.

Authors:  O Witschger; S A Grinshpun; S Fauvel; G Basso
Journal:  Ann Occup Hyg       Date:  2004-03-02

5.  Experimental methods to determine inhalability and personal sampler performance for aerosols in ultra-low windspeed environments.

Authors:  Darrah K Schmees; Yi-Hsuan Wu; James H Vincent
Journal:  J Environ Monit       Date:  2008-08-18

6.  Evaluation of IOM personal sampler at different flow rates.

Authors:  Yue Zhou; Yung-Sung Cheng
Journal:  J Occup Environ Hyg       Date:  2010-02       Impact factor: 2.155

7.  A collaborative European study of personal inhalable aerosol sampler performance.

Authors:  L C Kenny; R Aitken; C Chalmers; J F Fabriès; E Gonzalez-Fernandez; H Kromhout; G Lidén; D Mark; G Riediger; V Prodi
Journal:  Ann Occup Hyg       Date:  1997-04
  7 in total
  3 in total

1.  Solid versus liquid particle sampling efficiency of three personal aerosol samplers when facing the wind.

Authors:  Kirsten A Koehler; T Renee Anthony; Michael Van Dyke; John Volckens
Journal:  Ann Occup Hyg       Date:  2011-09-29

2.  A Simple and Disposable Sampler for Inhalable Aerosol.

Authors:  Christian L'Orange; Kimberly Anderson; Darrah Sleeth; T Renée Anthony; John Volckens
Journal:  Ann Occup Hyg       Date:  2015-10-14

3.  Comparison of coarse coal dust sampling techniques in a laboratory-simulated longwall section.

Authors:  Justin R Patts; Teresa L Barone
Journal:  J Occup Environ Hyg       Date:  2017-05       Impact factor: 2.155

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.