Literature DB >> 21083759

Optical quality and intraocular scattering in a healthy young population.

Joan A Martínez-Roda1, Meritxell Vilaseca, Juan C Ondategui, Anna Giner, Francisco J Burgos, Genís Cardona, Jaume Pujol.   

Abstract

BACKGROUND: We objectively assessed the optical quality and intraocular scattering by means of parameters provided by a clinical double-pass system in healthy young subjects and thereby we obtained new reference data for clinical diagnosis. We calculated normal values of neural contrast sensitivity function (nCSF) from the measured modulation transfer function (MTF) and the contrast sensitivity function (CSF).
METHODS: Eligible subjects were healthy adults aged from 18 to 30 years with a logMAR visual acuity (VA) of 0.0 or better and normal values of CSF. Optical quality measurements for a 4.0 mm pupil were performed using the Optical Quality Analysis System (OQAS) based on the double-pass technique. The following parameters were analysed: the modulation transfer function cutoff frequency (MTF(cutoff)), the Strehl(2D) ratio, the OQAS values (OV) at 100, 20 and nine per cent contrasts and the objective scatter index (OSI).
RESULTS: A total of 178 volunteers responded to the call, of whom 181 eyes were finally part of the study taking into account the criteria for inclusion. The values for the optical quality parameters were: 44.54 ± 7.14 cpd (MTF(cutoff)), 0.27 ± 0.06 (Strehl(2D) ratio), 1.48 ± 0.24 (OV(100%)), 1.58 ± 0.32 (OV(20%)), 1.64 ± 0.39 (OV(9%)), and 0.38 ± 0.19 (OSI). The nCSF calculated was 1.76 ± 0.21 (3 cpd), 2.13 ± 0.23 (6 cpd), 2.01 ± 0.28 (12 cpd) and 1.86 ± 0.33 (18 cpd).
CONCLUSION: The normal values provided can be a useful tool for discriminating healthy eyes from early abnormal ones in which the optical quality or sensory function is impaired.
© 2010 The Authors. Clinical and Experimental Optometry © 2010 Optometrists Association Australia.

Mesh:

Year:  2010        PMID: 21083759     DOI: 10.1111/j.1444-0938.2010.00535.x

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  30 in total

1.  Reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system.

Authors:  Ai-Lian Hu; Li-Ya Qiao; Ye Zhang; Xiao-Gu Cai; Lei Li; Xiu-Hua Wan
Journal:  Int J Ophthalmol       Date:  2015-10-18       Impact factor: 1.779

2.  Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor.

Authors:  Meritxell Vilaseca; Montserrat Arjona; Jaume Pujol; Elvira Peris; Vanessa Martínez
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

3.  Comparison of optical quality parameters and ocular aberrations after wavefront-guided laser in-situ keratomileusis versus wavefront-guided laser epithelial keratomileusis for myopia.

Authors:  Kwanghyun Lee; Ji Min Ahn; Eung Kweon Kim; Tae-im Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-05-08       Impact factor: 3.117

4.  High-gain visual feedback exacerbates ankle movement variability in children.

Authors:  Hwasil Moon; Changki Kim; MinHyuk Kwon; Yen-Ting Chen; Emily Fox; Evangelos A Christou
Journal:  Exp Brain Res       Date:  2015-03-06       Impact factor: 1.972

5.  Visual quality assessment after presbyopic laser in-situ keratomileusis.

Authors:  Dong Hui Lim; Eui-Sang Chung; Myoung Joon Kim; Tae-Young Chung
Journal:  Int J Ophthalmol       Date:  2018-03-18       Impact factor: 1.779

6.  Observational Clinical Studies of Human Lens Transparency Using the Vision Index Pen.

Authors:  Azin Abazari; Harbans S Dhadwal; John Wittpenn
Journal:  Transl Vis Sci Technol       Date:  2019-11-15       Impact factor: 3.283

7.  The recovery of optical quality after laser vision correction.

Authors:  Hyeong-Gi Jung; Tae-Hyung Lim
Journal:  Korean J Ophthalmol       Date:  2013-07-18

8.  Changes in Visual Performance under the Effects of Moderate-High Alcohol Consumption: The Influence of Biological Sex.

Authors:  Miriam Casares-López; José J Castro-Torres; Sonia Ortiz-Peregrina; Francesco Martino; Carolina Ortiz
Journal:  Int J Environ Res Public Health       Date:  2021-06-24       Impact factor: 3.390

9.  Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

Authors:  Mi Tian; Huamao Miao; Yang Shen; Jian Gao; Xiaofen Mo; Xingtao Zhou
Journal:  PLoS One       Date:  2015-11-04       Impact factor: 3.240

10.  Immature visual neural system in children reflected by contrast sensitivity with adaptive optics correction.

Authors:  Rong Liu; Jiawei Zhou; Haoxin Zhao; Yun Dai; Yudong Zhang; Yong Tang; Yifeng Zhou
Journal:  Sci Rep       Date:  2014-04-15       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.