AIM: To calculate the effective dose from cardiac multidetector computed tomography (MDCT) using a computer-based model utilizing the latest International Commission on Radiation Protection (ICRP) 103 tissue-weighting factors (2007), to compare this dose with those calculated with previously published chest conversion factors and to produce a conversion factor specific for cardiac MDCT. MATERIALS AND METHODS: An observational study of 152 patients attending for cardiac MDCT as part of their usual clinical care in a university teaching hospital. The dose for each examination was calculated using the computer-based anthropomorphic ImPACT model (the imaging performance assessment of CT scanners) and this was compared with the dose derived from the dose-length product (DLP) and a chest conversion factor. RESULTS: The median effective dose calculated using the ImPACT calculator (4.5 mSv) was significantly higher than the doses calculated with the chest conversion factors (2.2-3 mSv). CONCLUSION: The use of chest conversion factors significantly underestimates the effective dose when compared to the dose calculated using the ImPACT calculator. A conversion factor of 0.028 would give a better estimation of the effective dose from prospectively gated cardiac MDCT.
AIM: To calculate the effective dose from cardiac multidetector computed tomography (MDCT) using a computer-based model utilizing the latest International Commission on Radiation Protection (ICRP) 103 tissue-weighting factors (2007), to compare this dose with those calculated with previously published chest conversion factors and to produce a conversion factor specific for cardiac MDCT. MATERIALS AND METHODS: An observational study of 152 patients attending for cardiac MDCT as part of their usual clinical care in a university teaching hospital. The dose for each examination was calculated using the computer-based anthropomorphic ImPACT model (the imaging performance assessment of CT scanners) and this was compared with the dose derived from the dose-length product (DLP) and a chest conversion factor. RESULTS: The median effective dose calculated using the ImPACT calculator (4.5 mSv) was significantly higher than the doses calculated with the chest conversion factors (2.2-3 mSv). CONCLUSION: The use of chest conversion factors significantly underestimates the effective dose when compared to the dose calculated using the ImPACT calculator. A conversion factor of 0.028 would give a better estimation of the effective dose from prospectively gated cardiac MDCT.
Authors: F Tatsugami; M Matsuki; G Nakai; Y Inada; S Kanazawa; Y Takeda; H Morita; H Takada; S Yoshikawa; K Fukumura; Y Narumi Journal: Br J Radiol Date: 2012-01-17 Impact factor: 3.039