Literature DB >> 28900781

Submillisievert imaging protocol using full reconstruction and advanced patient motion correction in 320-row area detector coronary CT angiography.

Yuko Kawaguchi1, Shinichiro Fujimoto2, Kazuhisa Takamura1, Etsuro Kato1, Shoko Suda1, Rie Matsumori1, Makoto Hiki1, Kanako K Kumamaru3, Hiroyuki Daida1.   

Abstract

Radiation exposure remains a concern in the use of coronary CT angiography (CCTA). Full reconstruction (Full) and reconstruction using advanced patient motion correction (APMC) could obtain a lower radiation dose using low tube current scanning in a 320-row Area Detector CT (320-ADCT). The radiation dose for an imaging protocol using Full and APMC in daily practice was estimated. A total of 209 patients who underwent CCTA in 1 rotation scanning with 100 kv and adaptive iterative dose reduction 3D in 320-ADCT were enrolled. Imaging protocols were classified into 3 groups based on estimated slow filling time: (1) slow filling time ≥ 275 msec, Full with 30% of usual tube current (N = 43)(Full30%mA) (2) 206.3 msec ≤ slow filling time < 275 msec, APMC with 50% of usual tube current (N = 48)(APMC50%mA); and (3) 137.5 msec ≤ slow filling time < 206.3 msec, Half reconstruction with usual tube current (N = 118)(Half100%mA). Radiation dose was estimated by the effective dose. The diagnostic accuracy of CCTA was compared with that of invasive coronary angiography in 28 patients. The effective doses of Full30%mA, APMC50%mA, and Half100%mA were 0.77 ± 0.31, 1.30 ± 0.85, and 1.98 ± 0.68, respectively. Of 28 patients, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in vessel-based analyses were: Full30%mA, 66.7, 82.4, 80.0, 40.0, and 93.3%; APMC50%mA, 100.0, 80.0, 83.3, 50.05, and 100.0%; and Half100%mA, 90.9, 83.0, 86.3, 78.95, and 92.9%, respectively. An imaging protocol using Full30%mA and APMC50%mA was one of the methods how radiation dose could be reduced radiation dose maintained diagnostic accuracy compared to imaging using conventional Half100%mA.

Entities:  

Keywords:  320-row area detector coronary computed tomography angiography; Advanced patient motion correction; Full reconstruction; Radiation dosing; Submillisievert

Mesh:

Year:  2017        PMID: 28900781     DOI: 10.1007/s10554-017-1237-5

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  23 in total

1.  Subtraction coronary CT angiography using second-generation 320-detector row CT.

Authors:  Kunihiro Yoshioka; Ryoichi Tanaka; Kenta Muranaka; Tadashi Sasaki; Takanori Ueda; Takuya Chiba; Kouta Takeda; Tsuyoshi Sugawara
Journal:  Int J Cardiovasc Imaging       Date:  2015-02-27       Impact factor: 2.357

2.  Conversion factor for CT dosimetry to assess patient dose using a 256-slice CT scanner.

Authors:  S Mori; K Nishizawa; M Ohno; M Endo
Journal:  Br J Radiol       Date:  2006-05-25       Impact factor: 3.039

3.  Improved evaluation of calcified segments on coronary CT angiography: a feasibility study of coronary calcium subtraction.

Authors:  Ryoichi Tanaka; Kunihiro Yoshioka; Kenta Muranaka; Takuya Chiba; Takanori Ueda; Tadashi Sasaki; Tetsuya Fusazaki; Shigeru Ehara
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-25       Impact factor: 2.357

4.  ECG-edit function in multidetector-row computed tomography coronary arteriography for patients with arrhythmias.

Authors:  Hideyuki Matsutani; Tomonari Sano; Takeshi Kondo; Hitomi Morita; Takehiro Arai; Takako Sekine; Shinichi Takase; Akitsugu Oida; Hiroshi Fukazawa; Masahiko Suguta; Makoto Kondo; Takahide Kodama; Tadaaki Orihara; Norikazu Yamada; Masaharu Tsuyuki; Jagat Narula
Journal:  Circ J       Date:  2008-07       Impact factor: 2.993

5.  Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease.

Authors:  Yang Hou; Yue Ma; Weipeng Fan; Yuke Wang; Mei Yu; Mani Vembar; Qiyong Guo
Journal:  Eur Radiol       Date:  2013-07-26       Impact factor: 5.315

6.  [Clinical usefulness of low tube current scanning with full reconstruction and automatic patient motion correction (APMC) reconstruction in a prospective ECG-gated coronary CT angiography using 320-row area detector CT].

Authors:  Tomoya Takayanagi; Tomonari Sano; Takeshi Kondo; Makoto Amanuma; Kazumasa Ishizaka; Takako Sekine; Hideyuki Matsutani; Hitomi Morita; Takehiro Arai; Shinichi Takase
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2015-03

7.  A hybrid iterative reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography.

Authors:  Seitaro Oda; Daisuke Utsunomiya; Yoshinori Funama; Kazuchika Yonenaga; Tomohiro Namimoto; Takeshi Nakaura; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2012-05       Impact factor: 3.959

8.  Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography.

Authors:  Long Jiang Zhang; Yining Wang; U Joseph Schoepf; Felix G Meinel; Richard R Bayer; Li Qi; Jian Cao; Chang Sheng Zhou; Yan E Zhao; Xie Li; Jian Bin Gong; Zhengyu Jin; Guang Ming Lu
Journal:  Eur Radiol       Date:  2015-09-17       Impact factor: 5.315

9.  Accuracy of prospectively ECG-triggered very low-dose coronary dual-source CT angiography using iterative reconstruction for the detection of coronary artery stenosis: comparison with invasive catheterization.

Authors:  Christian Layritz; Jasmin Schmid; Stephan Achenbach; Stefan Ulzheimer; Wolfgang Wuest; Matthias May; Dieter Ropers; Lutz Klinghammer; Werner G Daniel; Tobias Pflederer; Michael Lell
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2014-06-17       Impact factor: 6.875

10.  Risk of cancer from occupational exposure to ionising radiation: retrospective cohort study of workers in France, the United Kingdom, and the United States (INWORKS).

Authors:  David B Richardson; Elisabeth Cardis; Robert D Daniels; Michael Gillies; Jacqueline A O'Hagan; Ghassan B Hamra; Richard Haylock; Dominique Laurier; Klervi Leuraud; Monika Moissonnier; Mary K Schubauer-Berigan; Isabelle Thierry-Chef; Ausrele Kesminiene
Journal:  BMJ       Date:  2015-10-20
View more
  2 in total

1.  Cardiovascular imaging 2017 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Amer Alaiti; Hiram G Bezerra; Johan De Sutter; Paul Schoenhagen; Arthur E Stillman; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2018-06       Impact factor: 2.357

Review 2.  Network Medicine: A Clinical Approach for Precision Medicine and Personalized Therapy in Coronary Heart Disease.

Authors:  Teresa Infante; Luca Del Viscovo; Maria Luisa De Rimini; Sergio Padula; Pio Caso; Claudio Napoli
Journal:  J Atheroscler Thromb       Date:  2019-11-12       Impact factor: 4.928

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.