Dimensional stability in composite cone beam computed tomography.

S Kopp1, P Ottl.   

Abstract

An automated increase in the field of view (FOV) for multipurpose cone beam CT (CBCT) by "stitching" (joining) up to three component volumes to yield a larger composite volume must still ensure dimensional stability, especially if the image is to form the basis for a surgical splint. Dimensional stability, image discrepancies and the influence of movement artefacts between exposures were evaluated. The first consumer installation of the Kodak 9000 three-dimensional (3D) extraoral imaging system with stitching software was used for the evaluation of a human mandible with three endodontic instruments as markers. The distances between several reproducible points were measured directly and the results compared with the values measured on screen. Displacements of the mandible along all axes between exposures as well as angular displacements were conducted to test the capability of the system. The standard deviations (SD) of the results for the vertical distances varied between 0.212 mm and 0.409 mm (approximately 1-2 voxels; range, 0.6-1.3 mm) and may be considered the systematic error. The SD of the results for the horizontal and diagonal distances varied between 0.195 mm and 0.571 mm (approximately 1-3 voxels; range, 0.6-1.7 mm) if the group with overall horizontal angulations of 10° and a central rotation of 20° was omitted. In conclusion, the evaluated stitching software is a useful tool to expand the options of combined CBCT with an initial small FOV by allowing a merger of up to three component volumes to yield a larger FOV of about 80 × 80 × 37 mm. The dimensional stability was acceptable when seen in relation to the induced disturbance. Further evaluation of this composite CBCT/digital imaging and communications in medicine system for subsequent splint fabrication may yield promising results.

Entities:  

Mesh:

Year:  2010        PMID: 21062945      PMCID: PMC3520214          DOI: 10.1259/dmfr/28358586

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  4 in total

1.  3D cone-beam CT reconstruction for circular trajectories.

Authors:  M Grass; T Köhler; R Proksa
Journal:  Phys Med Biol       Date:  2000-02       Impact factor: 3.609

2.  Value of image fusion in the staging of prostatic carcinoma.

Authors:  C Selli; D Caramella; S Giusti; A Conti; A Tognetti; A Mogorovich; M De Maria; C Bartolozzi
Journal:  Radiol Med       Date:  2007-02-22       Impact factor: 3.469

3.  Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS).

Authors:  Devon J Godfrey; Lei Ren; Hui Yan; Q Wu; Sua Yoo; M Oldham; Fang Fang Yin
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

4.  Linear accuracy of cone beam CT derived 3D images.

Authors:  April A Brown; William C Scarfe; James P Scheetz; Anibal M Silveira; Allan G Farman
Journal:  Angle Orthod       Date:  2009-01       Impact factor: 2.079

  4 in total
  4 in total

1.  Comparison of the accuracy of full head cone beam CT images obtained using a large field of view and stitched images.

Authors:  Mehmet Ozgur Ozemre; Ayse Gulsahi
Journal:  Dentomaxillofac Radiol       Date:  2018-06-19       Impact factor: 2.419

Review 2.  Technical aspects of dental CBCT: state of the art.

Authors:  R Pauwels; K Araki; J H Siewerdsen; S S Thongvigitmanee
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

3.  Accuracy and reliability of stitched cone-beam computed tomography images.

Authors:  Nicholas Egbert; David R Cagna; Swati Ahuja; Russell A Wicks
Journal:  Imaging Sci Dent       Date:  2015-03-13

4.  Accuracy of linear measurements obtained from stitched cone beam computed tomography images versus direct skull measurements.

Authors:  Doaa Ahmed Fouad Hamed; Mostafa Mohamed El Dawlatly; Sahar Hosny El Dessouky; Reham Mohamed Hamdy
Journal:  F1000Res       Date:  2019-02-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.