3D cone-beam CT reconstruction for circular trajectories.

M Grass1, T Köhler, R Proksa.   

Abstract

3D reconstruction from 2D projections obtained along a single circular source trajectory is most commonly done using an algorithm due to Feldkamp, Davis and Kress. In this paper we propose an alternative approach based on a cone-beam to parallel-beam rebinning step, a corresponding rebinning step into a rectangular virtual detector plane and a filtered backprojection. This approach yields an improved image quality reflected by a decreased low-intensity drop which is well known for 3D reconstruction from projection data obtained along circular trajectories. At the same time the computational complexity is lower than in Feldkamp's original approach. Based on this idea, a hybrid 3D cone-beam reconstruction method is formulated that enlarges the reconstruction volume in its dimension along the rotation axis of the cone-beam CT system. This enlargement is achieved by applying different reconstruction conditions for each voxel. An optimal ratio between the reconstructible and irradiated volume of the scanned object is achieved.

Mesh:

Year:  2000        PMID: 10701507     DOI: 10.1088/0031-9155/45/2/306

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  Cone-beam artifact evaluation of the factorization method.

Authors:  Frank Dennerlein; Frédéric Noo
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

Review 2.  Application of polychromatic µCT for mineral density determination.

Authors:  W Zou; N Hunter; M V Swain
Journal:  J Dent Res       Date:  2010-09-21       Impact factor: 6.116

3.  Dimensional stability in composite cone beam computed tomography.

Authors:  S Kopp; P Ottl
Journal:  Dentomaxillofac Radiol       Date:  2010-12       Impact factor: 2.419

4.  Three-dimensional texture analysis of cancellous bone cores evaluated at clinical CT resolutions.

Authors:  Chad Showalter; Bradley D Clymer; Bradford Richmond; Kimerly Powell
Journal:  Osteoporos Int       Date:  2005-09-17       Impact factor: 4.507

5.  A factorization approach for cone-beam reconstruction on a circular short-scan.

Authors:  Frank Dennerlein; Frédéric Noo; Harald Schöndube; Günter Lauritsch; Joachim Hornegger
Journal:  IEEE Trans Med Imaging       Date:  2008       Impact factor: 10.048

6.  The Effect of Surgical Technique and Spacer Texture on Bone Regeneration: A Caprine Study Using the Masquelet Technique.

Authors:  Viviane Luangphakdy; G Elizabeth Pluhar; Nicolás S Piuzzi; Jean-Claude D'Alleyrand; Cathy S Carlson; Joan E Bechtold; Jonathan Forsberg; George F Muschler
Journal:  Clin Orthop Relat Res       Date:  2017-06-20       Impact factor: 4.176

7.  Generation of voxelized breast phantoms from surgical mastectomy specimens.

Authors:  J Michael O'Connor; Mini Das; Clay S Dider; Mufeed Mahd; Stephen J Glick
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

8.  In vivo longitudinal assessment of bone resorption in a fibular osteotomy model using micro-computed tomography.

Authors:  Kim A Powell; Larry Latson; Michael O Ibiwoye; Alan Wolfman; Mark D Grabiner; Maciej Zborowski; Yoshitada Sakai; Ronald J Midura
Journal:  Iowa Orthop J       Date:  2005

9.  Experimental study of intracranial hematoma detection with flat panel detector C-arm CT.

Authors:  H Arakawa; M P Marks; H M Do; D M Bouley; N Strobel; T Moore; R Fahrig
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-17       Impact factor: 3.825

10.  Low-noise dynamic reconstruction for x-ray tomographic perfusion studies using low sampling rates.

Authors:  Pau Montes; Günter Lauritsch
Journal:  Int J Biomed Imaging       Date:  2010-01-17