Literature DB >> 17879800

Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS).

Devon J Godfrey1, Lei Ren, Hui Yan, Q Wu, Sua Yoo, M Oldham, Fang Fang Yin.   

Abstract

Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-angle scan, with typical scan angles ranging from 10 degrees to 40 degrees and acquisition times of less than 10 s. The resulting DTS slices show soft tissue contrast approaching that of full cone-beam CT. External beam radiotherapy target localization using DTS requires the registration of on-board DTS images with corresponding reference image data. This study evaluates three types of reference volume: original reference CT, exact reference DTS (RDTS), and a more computationally efficient approximate reference DTS (RDTSapprox), as well as three different DTS scan angles (22 degrees, 44 degrees, and 65 degrees) for the DTS target localization task. Three-dimensional mutual information (MI) shared between reference and onboard DTS volumes was computed in a region surrounding the spine of a chest phantom, as translations spanning +/-5 mm and rotations spanning +/-5 degrees were simulated along each dimension in the reference volumes. The locations of the MI maxima were used as surrogates for registration accuracy, and the width of the MI peaks were used to characterize the registration robustness. The results show that conventional treatment planning CT volumes are inadequate reference volumes for direct registration with on-board DTS data. The efficient RDTSapprox method also appears insufficient for MI-based registration without further refinement of the technique, though it may be suitable for manual registration performed by a human observer. The exact RDTS volumes, on the other hand, delivered a 3D DTS localization accuracy of 0.5 mm and 0.50 along each axis, using only a single 44 degrees coronal on-board DTS scan of the chest phantom.

Entities:  

Mesh:

Year:  2007        PMID: 17879800     DOI: 10.1118/1.2756941

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Dimensional stability in composite cone beam computed tomography.

Authors:  S Kopp; P Ottl
Journal:  Dentomaxillofac Radiol       Date:  2010-12       Impact factor: 2.419

2.  Fast reconstruction of digital tomosynthesis using on-board images.

Authors:  Hui Yan; Devon J Godfrey; Fang-Fang Yin
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

Review 3.  Tomosynthesis imaging: at a translational crossroads.

Authors:  James T Dobbins
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

Review 4.  A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  Evaluation of respiration-correlated digital tomosynthesis in lung.

Authors:  Joseph Santoro; Sergey Kriminski; D Michael Lovelock; Kenneth Rosenzweig; Hassan Mostafavi; Howard I Amols; Gig S Mageras
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

6.  Method comparison of automated matching software-assisted cone-beam CT and stereoscopic kilovoltage x-ray positional verification image-guided radiation therapy for head and neck cancer: a prospective analysis.

Authors:  Clifton D Fuller; Todd J Scarbrough; Jan-Jakob Sonke; Coen R N Rasch; Mehee Choi; Joe Y Ting; Samuel J Wang; Niko Papanikolaou; David I Rosenthal
Journal:  Phys Med Biol       Date:  2009-11-24       Impact factor: 3.609

7.  A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map.

Authors:  Lei Ren; Junan Zhang; Danthai Thongphiew; Devon J Godfrey; Q Jackie Wu; Su-Min Zhou; Fang-Fang Yin
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

8.  Clinical evaluation of positioning verification using digital tomosynthesis and bony anatomy and soft tissues for prostate image-guided radiotherapy.

Authors:  Sua Yoo; Q Jackie Wu; Devon Godfrey; Hui Yan; Lei Ren; Shiva Das; William R Lee; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-01-01       Impact factor: 7.038

9.  Clinical Study of Orthogonal-View Phase-Matched Digital Tomosynthesis for Lung Tumor Localization.

Authors:  You Zhang; Lei Ren; Irina Vergalasova; Fang-Fang Yin
Journal:  Technol Cancer Res Treat       Date:  2017-04-28

10.  Optimal parameters for clinical implementation of breast cancer patient setup using Varian DTS software.

Authors:  Sook Kien Ng; Piotr Zygmanski; Andrew Jeung; Hassan Mostafavi; Juergen Hesser; Jennifer R Bellon; Julia S Wong; Yulia Lyatskaya
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.