Literature DB >> 19123719

Linear accuracy of cone beam CT derived 3D images.

April A Brown1, William C Scarfe, James P Scheetz, Anibal M Silveira, Allan G Farman.   

Abstract

OBJECTIVE: To compare the in vitro reliability and accuracy of linear measurements between cephalometric landmarks on cone beam computed tomography (CBCT) 3D volumetric images with varying basis projection images to direct measurements on human skulls.
MATERIALS AND METHODS: Sixteen linear dimensions between 24 anatomic sites marked on 19 human skulls were directly measured. The skulls were imaged with CBCT (i-CAT, Imaging Sciences International, Hatfield, Pa) at three settings: (a) 153 projections, (b) 306 projections, and (c) 612 projections. The mean absolute error and modality mean (+/- SD) of linear measurements between landmarks on volumetric renderings were compared to the anatomic truth using repeated measures general linear model (P < or = .05).
RESULTS: No difference in mean absolute error between the scan settings was found for almost all measurements. The average skull absolute error between marked reference points was less than the distances between unmarked reference sites. CBCT resulted in lower measurements for nine dimensions (mean difference range: 3.1 mm +/- 0.12 mm to 0.56 mm +/- 0.07 mm) and a greater measurement for one dimension (mean difference 3.3 mm +/- 0.12 mm). No differences were detected between CBCT scan sequences.
CONCLUSIONS: CBCT measurements were consistent between scan sequences and for direct measurements between marked reference points. Reducing the number of projections for 3D reconstruction did not lead to reduced dimensional accuracy and potentially provides reduced patient radiation exposure. Because the fiducial landmarks on the skulls were not radio-opaque, the inaccuracies found in measurement could be due to the methods applied rather than to innate inaccuracies in the CBCT scan reconstructions or 3D software employed.

Entities:  

Mesh:

Year:  2009        PMID: 19123719     DOI: 10.2319/122407-599.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  49 in total

1.  Comparative study between conventional and cone beam CT-synthesized half and total skull cephalograms.

Authors:  G S Liedke; E L Delamare; M B Vizzotto; H L D da Silveira; J R Prietsch; V Dutra; H E D da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2012-02       Impact factor: 2.419

2.  3D cephalometric analysis obtained from computed tomography. Review of the literature.

Authors:  Giulia Rossini; Costanza Cavallini; Michele Cassetta; Ersilia Barbato
Journal:  Ann Stomatol (Roma)       Date:  2012-01-27

3.  Digital method for quantification of circumferential periodontal bone level using cone beam CT.

Authors:  Jonathan Fleiner; Christian Hannig; Dirk Schulze; Andres Stricker; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2012-03-21       Impact factor: 3.573

4.  A computerized tomography study of the morphological interrelationship between the temporal bones and the craniofacial complex.

Authors:  Helder Nunes Costa; Rudolf Slavicek; Sadao Sato
Journal:  J Anat       Date:  2012-03-28       Impact factor: 2.610

5.  Comparison of linear and angular measurements using two-dimensional conventional methods and three-dimensional cone beam CT images reconstructed from a volumetric rendering program in vivo.

Authors:  U Oz; K Orhan; N Abe
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

6.  Accuracy of CBCT measurements of a human skull.

Authors:  Kivanç Kamburoğlu; Eray Kolsuz; Hakan Kurt; Cenk Kiliç; Tuncer Özen; Candan Semra Paksoy
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

Review 7.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

8.  Dimensional stability in composite cone beam computed tomography.

Authors:  S Kopp; P Ottl
Journal:  Dentomaxillofac Radiol       Date:  2010-12       Impact factor: 2.419

9.  Development of a low-dose protocol for cone beam CT examinations of the anterior maxilla in children.

Authors:  Jose A Hidalgo Rivas; Keith Horner; Badri Thiruvenkatachari; Jonathan Davies; Chrysoula Theodorakou
Journal:  Br J Radiol       Date:  2015-08-17       Impact factor: 3.039

Review 10.  Conventional radiography and cross-sectional imaging when planning dental implants in the anterior edentulous mandible to support an overdenture: a systematic review.

Authors:  A M Shelley; A-M Glenny; M Goodwin; P Brunton; K Horner
Journal:  Dentomaxillofac Radiol       Date:  2013-11-22       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.