Literature DB >> 20876433

Downloadable software algorithm reduces inappropriate shocks caused by implantable cardioverter-defibrillator lead fractures: a prospective study.

Charles D Swerdlow1, Bruce D Gunderson, Kevin T Ousdigian, Athula Abeyratne, Haresh Sachanandani, Kenneth A Ellenbogen.   

Abstract

BACKGROUND: Downloadable software upgrades are common in consumer electronics but not in implantable medical devices. Fractures of implantable cardioverter-defibrillator (ICD) leads present commonly as inappropriate shocks. A lead-integrity alert (LIA) designed to reduce inappropriate shocks is the first software download approved to enhance nominally functioning, previously implanted ICDs. METHODS AND
RESULTS: We performed a prospective study to determine whether an LIA could reduce inappropriate shocks. Patients were included if they had ICD lead fractures confirmed by analysis of explanted leads. The LIA group included the first 213 patients who met the inclusion criteria after the LIA was approved who had the LIA downloaded. The LIA is triggered either by high impedance or rapid oversensing. It responds by delaying detection of ventricular fibrillation and initiating a patient alert every 4 hours. The control group included the first 213 patients who did not have the LIA downloaded. They were monitored by conventional daily impedance measurements that respond with a daily alert. The LIA group had a 46% relative reduction (95% confidence interval 34% to 55%) in the percentage of patients with ≥1 inappropriate shock (LIA 38% versus control 70%, P<0.001) and a 50% relative reduction (95% confidence interval 33% to 61%) in the percentage with ≥5 shocks (25% versus 50%, P<0.001). The LIA group also had a higher percentage of patients who either did not receive a shock or had ≥3 days of warning before the shock (72% versus 50%, P<0.001).
CONCLUSIONS: A software download that upgrades previously implanted ICDs without surgical revision reduces inappropriate shocks caused by lead fractures.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20876433     DOI: 10.1161/CIRCULATIONAHA.110.962407

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  15 in total

1.  [Lead survival and complications (except infections). Are we doing better nowadays?].

Authors:  Martin Seifert; Michael Neuss; Maren Schöpp; Cornel Koban; Christian Butter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-08-06

Review 2.  [ICD leads].

Authors:  Carsten W Israel; Mohamed Karim Sheta
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-06

Review 3.  Sensing and detection in Medtronic implantable cardioverter defibrillators.

Authors:  Mark L Brown; Charles D Swerdlow
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-09-08

4.  Postmarket surveillance of medical devices: current capabilities and future opportunities.

Authors:  Kathleen Blake
Journal:  J Interv Card Electrophysiol       Date:  2013-03-12       Impact factor: 1.900

5.  Evaluation of defibrillation safety and shock reduction in implantable cardioverter-defibrillator patients with increased time to detection: A randomized SANKS study.

Authors:  Mahito Noro; Xin Zhu; Takahito Takagi; Naohiko Sahara; Yuriko Narabayashi; Hikari Hashimoto; Naoshi Ito; Yoshinari Enomoto; Shingo Kujime; Tuyoshi Sakai; Takao Sakata; Noriko Matushita; Seiji Fukamizu; Yoshifumi Okano; Yoshiaki Anami; Tomoyuki Tejima; Kouji Kuroiwa; Takanori Ikeda; Harumizu Sakurada; Kaoru Sugi
Journal:  J Arrhythm       Date:  2014-09-26

6.  ICD therapy for primary prevention of sudden cardiac death after Mustard repair for d-transposition of the great arteries.

Authors:  David Backhoff; Matthias Müller; Wolfgang Ruschewski; Thomas Paul; Ulrich Krause
Journal:  Clin Res Cardiol       Date:  2014-05-29       Impact factor: 5.460

7.  Incidence of nonphysiologic short VV intervals detected by the sensing integrity counter with integrated bipolar compared with true bipolar leads: clinically inconsequential or cause for concern?

Authors:  Justin Ng; Nagesh Chopra; Chirag Barbhaiya; Tobias Reichlin; Eyal Nof; Koichi Nagashima; Thomas Tadros; Bruce A Koplan
Journal:  J Interv Card Electrophysiol       Date:  2014-02-16       Impact factor: 1.900

8.  Predictors and clinical impact of inappropriate implantable cardioverter-defibrillator shocks in Korean patients.

Authors:  Jeong Hoon Yang; Kyeongmin Byeon; Hye Ran Yim; Jung Wae Park; Seung-Jung Park; June Huh; June Soo Kim; Young Keun On
Journal:  J Korean Med Sci       Date:  2012-05-26       Impact factor: 2.153

9.  Managing patients with advisory defibrillator leads: what can we learn from published data?

Authors:  F A Bracke; B M van Gelder
Journal:  Neth Heart J       Date:  2015-04       Impact factor: 2.380

10.  2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.

Authors:  Bruce L Wilkoff; Laurent Fauchier; Martin K Stiles; Carlos A Morillo; Sana M Al-Khatib; Jesœs Almendral; Luis Aguinaga; Ronald D Berger; Alejandro Cuesta; James P Daubert; Sergio Dubner; Kenneth A Ellenbogen; N A Mark Estes; Guilherme Fenelon; Fermin C Garcia; Maurizio Gasparini; David E Haines; Jeff S Healey; Jodie L Hurtwitz; Roberto Keegan; Christof Kolb; Karl-Heinz Kuck; Germanas Marinskis; Martino Martinelli; Mark McGuire; Luis G Molina; Ken Okumura; Alessandro Proclemer; Andrea M Russo; Jagmeet P Singh; Charles D Swerdlow; Wee Siong Teo; William Uribe; Sami Viskin; Chun-Chieh Wang; Shu Zhang
Journal:  J Arrhythm       Date:  2016-02-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.