Literature DB >> 20830258

Implantable cardioverter-defibrillator lead extraction by conventional traction and counter-traction technique.

Jong Sung Park1, Hui-Nam Pak, Moon-Hyoung Lee, Sung Soon Kim, Boyoung Joung.   

Abstract

A 46-year-old man presented to our institution with inappropriate implantable cardioverter-defibrillator (ICD) shock delivery. The ICD (single chamber, dual shock coils) was implanted for sustained monomorphic ventricular tachycardia with unstable hemodynamics and underlying systolic left ventricular dysfunction. ICD interrogation revealed recurrent episodes of ICD shock due to noise sensing and increased impedance of right ventricular (RV)-lead. With the impression of lead fracture, ICD lead extraction was performed. The fractured ICD lead was completely removed by traction of locking stylet and counter-traction of polypropylene dilator sheath. A new lead was inserted and the patient was discharged without complications after 2 days. To our knowledge, this is the first report on ICD lead extraction by conventional traction and counter-traction technique in Korea.

Entities:  

Keywords:  Device failure, Implantable cardioverter defibrillator; Device removal

Year:  2010        PMID: 20830258      PMCID: PMC2933469          DOI: 10.4070/kcj.2010.40.8.418

Source DB:  PubMed          Journal:  Korean Circ J        ISSN: 1738-5520            Impact factor:   3.243


  12 in total

1.  Pacemaker lead extraction with the needle's eye snare for countertraction via a femoral approach.

Authors:  Didier Klug; Moustapha Jarwé; Seddik Ait Messaoudéne; Claude Kouakam; Christelle Marquié; Alain Gay; Dominique Lacroix; Salem Kacet
Journal:  Pacing Clin Electrophysiol       Date:  2002-07       Impact factor: 1.976

2.  Noninstrumental pacemaker and defibrillator lead removal. The importance of the rotation forces.

Authors:  Shimon Rosenheck; Alexey Weiss; David Leibowitz; Zehava Sharon
Journal:  Pacing Clin Electrophysiol       Date:  2002-07       Impact factor: 1.976

3.  Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trial.

Authors:  Petr Neuzil; Milos Taborsky; Zdenek Rezek; Roman Vopalka; Lucie Sediva; Petr Niederle; Vivek Reddy
Journal:  Europace       Date:  2007-02       Impact factor: 5.214

4.  Three-year experience with a stylet for lead extraction: a multicenter study.

Authors:  E Alt; J Neuzner; L Binner; K Göhl; J C Res; U H Knabe; M Zehender; J Reinhardt
Journal:  Pacing Clin Electrophysiol       Date:  1996-01       Impact factor: 1.976

5.  Cerebral embolism due to a retained pacemaker lead: a case report.

Authors:  A Böhm; F Bányai; K Komáromy; A Pintér; I Préda
Journal:  Pacing Clin Electrophysiol       Date:  1998-03       Impact factor: 1.976

6.  Undertreatment and overtreatment of patients with infected antiarrhythmic implantable devices.

Authors:  J E Molina
Journal:  Ann Thorac Surg       Date:  1997-02       Impact factor: 4.330

7.  Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrode.

Authors:  A E Becker; M J Becker; D G Claudon; J E Edwards
Journal:  Circulation       Date:  1972-08       Impact factor: 29.690

8.  Pulmonary arterial embolization of pacemaker lead electrode tip.

Authors:  Robert E Eckart; Tomasz W Hruczkowski; Michael J Landzberg; Alyson Ames; Laurence M Epstein
Journal:  Pacing Clin Electrophysiol       Date:  2006-07       Impact factor: 1.976

9.  Five-years experience with intravascular lead extraction. U.S. Lead Extraction Database.

Authors:  H J Smith; N E Fearnot; C L Byrd; B L Wilkoff; C J Love; T D Sellers
Journal:  Pacing Clin Electrophysiol       Date:  1994-11       Impact factor: 1.976

10.  Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996. U.S. Extraction Database, MED Institute.

Authors:  C L Byrd; B L Wilkoff; C J Love; T D Sellers; K T Turk; R Reeves; R Young; B Crevey; S P Kutalek; R Freedman; R Friedman; J Trantham; M Watts; J Schutzman; J Oren; J Wilson; F Gold; N E Fearnot; H J Van Zandt
Journal:  Pacing Clin Electrophysiol       Date:  1999-09       Impact factor: 1.976

View more
  1 in total

1.  Retraction: Implantable Cardioverter-Defibrillator Lead Extraction by Conventional Traction and Counter-Traction Technique.

Authors:  Jong Sung Park; Hui-Nam Pak; Moon-Hyoung Lee; Sung Soon Kim; Boyoung Joung
Journal:  Korean Circ J       Date:  2016-01-14       Impact factor: 3.243

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.