Literature DB >> 12164441

Pacemaker lead extraction with the needle's eye snare for countertraction via a femoral approach.

Didier Klug1, Moustapha Jarwé, Seddik Ait Messaoudéne, Claude Kouakam, Christelle Marquié, Alain Gay, Dominique Lacroix, Salem Kacet.   

Abstract

Femoral approach pacemaker lead extraction is described as a safe and efficacious procedure. When the lead can not be removed from its myocardial insertion, the "Needle's eye snare" has become available, and it allows a femoral approach traction associated with a countertraction. Between May 1998 and May 2000, 222 lead extraction procedures were performed in 99 patients using the femoral approach. This article reports the results of the 70 lead extractions requiring the use of the Needle's eye snare for femoral approach countertraction in 39 patients with a total of 82 leads. The indications were infection, accufix leads and lead dysfunction in 56, 1 and 6 leads, respectively. The age of the leads was 113 +/- 56 months. Sixty-one (87.2%) leads were successfully extracted, the extraction was incomplete in 3 (4.3%) cases and failed in 6 (8.5%) cases. The failures were due to leads totally excluded from the venous flow for four leads, the impossibility of advancing the 16 Fr long sheath through the right and left iliac veins for one lead and one traction induced a nontolerated ventricular arrhythmia. In these cases, an extraction by a simple upper traction had been attempted in another center several months before. The complications included two deaths and one transient ischemia of the right inferior limb. Despite the selection of a series of leads for which an extraction by a simple traction on the proximal end of the lead was impossible or unsuccessful, femoral countertraction seems to be a safe and efficacious procedure. The failure of this technique occurred in patients with damaged leads due to a previous extraction procedure performed in centers with limited experience in lead extraction.

Entities:  

Mesh:

Year:  2002        PMID: 12164441     DOI: 10.1046/j.1460-9592.2002.01023.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  9 in total

1.  Implantable cardioverter-defibrillator lead extraction by conventional traction and counter-traction technique.

Authors:  Jong Sung Park; Hui-Nam Pak; Moon-Hyoung Lee; Sung Soon Kim; Boyoung Joung
Journal:  Korean Circ J       Date:  2011-03-31       Impact factor: 3.243

Review 2.  [ICD lead defects: diagnosis and therapeutical options].

Authors:  Christian G Wollmann; Dirk Böcker; Andreas Löher; Hans H Scheld; Günter Breithardt; Rainer Gradaus
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-02-11

3.  Implantable cardioverter-defibrillator lead extraction by conventional traction and counter-traction technique.

Authors:  Jong Sung Park; Hui-Nam Pak; Moon-Hyoung Lee; Sung Soon Kim; Boyoung Joung
Journal:  Korean Circ J       Date:  2010-08-31       Impact factor: 3.243

4.  Lead extraction: "drag through" technique.

Authors:  Anoop K Gupta
Journal:  Indian Pacing Electrophysiol J       Date:  2002-10-01

5.  The lead extractor's toolbox: a review of current endovascular pacemaker and ICD lead extraction techniques.

Authors:  F A Bracke
Journal:  Indian Pacing Electrophysiol J       Date:  2003-07-01

6.  Transvenous Lead Extraction via the Inferior Approach Using a Gooseneck Snare versus Simple Manual Traction.

Authors:  Uk Jo; Jun Kim; You-Mi Hwang; Ji-Hyun Lee; Min-Su Kim; Hyung-Oh Choi; Woo-Seok Lee; Chang-Hee Kwon; Gi-Young Ko; Hyun-Ki Yoon; Gi-Byoung Nam; Kee-Joon Choi; You-Ho Kim
Journal:  Korean Circ J       Date:  2016-03-21       Impact factor: 3.243

7.  "Spaghetti twisting" technique: a novel method of catching pacemaker leads using a needle's eye snare.

Authors:  Tsuyoshi Isawa; Takashi Yamada; Taku Honda; Kazuhiro Yamaya; Tatsushi Ootomo
Journal:  Clin Case Rep       Date:  2017-06-23

8.  Procedural outcome of lead explant and countertraction-assisted femoral lead extraction in Thai patients with cardiac implantable electronic device infection.

Authors:  Jirarat Jiratham-Opas; Narawudt Prasertwitayakij; Teerapat Nantsupawat; Wanwarang Wongcharoen
Journal:  J Arrhythm       Date:  2021-08-05

9.  Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads.

Authors:  Maria Grazia Bongiorni; Ezio Soldati; Giulio Zucchelli; Andrea Di Cori; Luca Segreti; Raffaele De Lucia; Gianluca Solarino; Alberto Balbarini; Mario Marzilli; Mario Mariani
Journal:  Eur Heart J       Date:  2008-10-23       Impact factor: 29.983

  9 in total