Experimental validation of a commercial 3D dose verification system for intensity-modulated arc therapies.

Ramesh Boggula1, Friedlieb Lorenz, Lutz Mueller, Mattias Birkner, Hansjoerg Wertz, Florian Stieler, Volker Steil, Frank Lohr, Frederik Wenz.   

Abstract

We validate the dosimetric performance of COMPASS®, a novel 3D quality assurance system for verification of volumetric-modulated arc therapy (VMAT) treatment plans that can correlate the delivered dose to the patient's anatomy, taking into account the tissue inhomogeneity. The accuracy of treatment delivery was assessed by the COMPASS® for 12 VMAT plans, and the resulting assessments were evaluated using an ionization chamber and film measurements. Dose-volume relationships were evaluated by the COMPASS® for three additional treatment plans and these were used to verify the accuracy of treatment planning dose calculations. The results matched well between COMPASS® and measurements for the ionization chamber (≤3%) and film (73-99% for gamma((3%/3 mm)) < 1 and 98-100% for gamma((5%/5 mm)) < 1) for the phantom plans. Differences in dose-volume statistics for the average dose to the PTV were within 2.5% for three treatment plans. For the structures located in the low-dose region, a maximum difference of <9% was observed. In its current implementation, the system could measure the delivered dose with sufficient accuracy and could project the 3D dose distribution directly on the patient's anatomy. Slight deviations were found for large open fields. These could be minimized by improving the COMPASS® in-built beam model.

Entities:  

Mesh:

Year:  2010        PMID: 20826904     DOI: 10.1088/0031-9155/55/19/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  Dose verification of IMRT by use of a COMPASS transmission detector.

Authors:  Yuji Nakaguchi; Fujio Araki; Masato Maruyama; Shunji Saiga
Journal:  Radiol Phys Technol       Date:  2011-10-26

2.  [Image-guided radiation therapy. Paradigm change in radiation therapy].

Authors:  F Wenz; C Belka; M Reiser; S O Schönberg
Journal:  Radiologe       Date:  2012-03       Impact factor: 0.635

3.  Independent calculation of monitor units for VMAT and SPORT.

Authors:  Xin Chen; Karl Bush; Aiping Ding; Lei Xing
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

4.  Validation of a quick three-dimensional dose verification system for pre-treatment IMRT QA.

Authors:  Yuji Nakaguchi; Fujio Araki; Takeshi Ono; Yuki Tomiyama; Masato Maruyama; Nozomu Nagasue; Yoshinobu Shimohigashi; Yudai Kai
Journal:  Radiol Phys Technol       Date:  2014-09-27

5.  Commissioning and validation of fluence-based 3D VMAT dose reconstruction system using new transmission detector.

Authors:  Yuji Nakaguchi; Takeshi Oono; Masato Maruyama; Yoshinobu Shimohigashi; Yudai Kai; Yuya Nakamura
Journal:  Radiol Phys Technol       Date:  2018-03-12

6.  Deep Learning for Patient-Specific Quality Assurance: Predicting Gamma Passing Rates for IMRT Based on Delivery Fluence Informed by log Files.

Authors:  Ying Huang; Yifei Pi; Kui Ma; Xiaojuan Miao; Sichao Fu; Zhen Zhu; Yifan Cheng; Zhepei Zhang; Hua Chen; Hao Wang; Hengle Gu; Yan Shao; Yanhua Duan; Aihui Feng; Weihai Zhuo; Zhiyong Xu
Journal:  Technol Cancer Res Treat       Date:  2022 Jan-Dec

7.  Validation of Dolphin dosimetry in three dimensional patient-specific quality assurance programme.

Authors:  Niyas Puzhakkal; Abdullah Kallikuzhiyil Kochunny; Dinesh Makuny; Arun Krishnan M P; Ranjith C Poyil; Vysakh Raveendran
Journal:  Rep Pract Oncol Radiother       Date:  2019-08-12

8.  A method to improve fluence resolution derived from two-dimensional detector array measurements for patient-specific IMRT verification using the information collected in dynalog files.

Authors:  Juan Agustin Calama Santiago; Miguel Angel Infante Utrilla; Maria Elisa Lavado Rodriguez
Journal:  J Med Phys       Date:  2015 Jan-Mar

9.  Comparison of 3D anatomical dose verification and 2D phantom dose verification of IMRT/VMAT treatments for nasopharyngeal carcinoma.

Authors:  Hailei Lin; Shaomin Huang; Xiaowu Deng; Jinhan Zhu; Lixin Chen
Journal:  Radiat Oncol       Date:  2014-03-07       Impact factor: 3.481

10.  Critical appraisal of the accuracy of Acuros-XB and Anisotropic Analytical Algorithm compared to measurement and calculations with the compass system in the delivery of RapidArc clinical plans.

Authors:  Murugesan Kathirvel; Shanmuga Subramanian; Alessandro Clivio; Gandhi Arun; Antonella Fogliata; Giorgia Nicolini; Vellaiyan Subramani; Shanmugam Thirumalai Swamy; Eugenio Vanetti; Luca Cozzi
Journal:  Radiat Oncol       Date:  2013-06-11       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.