Water-equivalent pathlength reproducibility due to respiratory pattern variation in charged-particle pancreatic radiotherapy.

Motoki Kumagai1, Shinichiro Mori, Ryusuke Hara, Hiroshi Asakura, Riwa Kishimoto, Hirotoshi Kato, Shigeru Yamada, Susumu Kandatsu.   

Abstract

We evaluated the water-equivalent length (WEL) reproducibility due to variation in the external respiratory marker position when using a 4DCT scan in respiratory-gated charged-particle treatment. Two sets of pancreatic 4DCT data from two patients were acquired under free breathing conditions with 256-slice CT. The 4DCT data included two exhalation phases and the respiratory patterns in each patient differed, one being regular and the other irregular. The WEL calculation region is defined in the first respiratory cycle by two planes, one at the patient entrance surface and the other behind the target in the anterior-posterior (AP) and posterior-anterior (PA) directions. In the regular respiratory pattern, the WEL variation within the target region was less than 1.7 mm between the first and second exhalations in both AP and PA calculation directions. However, in the irregular breathing pattern, the respiratory amplitude at the second exhalation was 20% lower than that at the first exhalation; therefore, WEL variations from 8.1 to -9.1 mm and from 3.1 to -3.4 mm were observed within the target region in the AP and PA calculation directions, respectively. The WEL variation in the PA direction was smaller than that in the AP direction because the abdominal thickness is affected more in the AP direction. Respiratory pattern variation even affects WEL values in the respiratory-gated phase. This variation should be considered in treatment planning, and necessary improvements in respiratory reproducibility should be made.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 20821137     DOI: 10.1007/s12194-008-0052-z

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  22 in total

1.  Design study of a raster scanning system for moving target irradiation in heavy-ion radiotherapy.

Authors:  Takuji Furukawa; Taku Inaniwa; Shinji Sato; Takehiro Tomitani; Shinichi Minohara; Koji Noda; Tatsuaki Kanai
Journal:  Med Phys       Date:  2007-03       Impact factor: 4.071

2.  New accelerator facility for carbon-ion cancer-therapy.

Authors:  Koji Noda; Takuji Furukawa; Takashi Fujisawa; Yoshiyuki Iwata; Tatsuaki Kanai; Mitsutaka Kanazawa; Atsushi Kitagawa; Masataka Komori; Shinichi Minohara; Takeshi Murakami; Masayuki Muramatsu; Shinji Sato; Yuka Takei; Mutsumi Tashiro; Masami Torikoshi; Satoru Yamada; Ken Yusa
Journal:  J Radiat Res       Date:  2007       Impact factor: 2.724

3.  Optimal short scan convolution reconstruction for fanbeam CT.

Authors:  D L Parker
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

Review 4.  Breathing pattern in humans: diversity and individuality.

Authors:  G Benchetrit
Journal:  Respir Physiol       Date:  2000-09

5.  Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging.

Authors:  E C Ford; G S Mageras; E Yorke; K E Rosenzweig; R Wagman; C C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-02-01       Impact factor: 7.038

6.  Development and performance evaluation of the second model 256-detector row CT.

Authors:  Masahiro Endo; Shinichiro Mori; Susumu Kandatsu; Shuji Tanada; Chisato Kondo
Journal:  Radiol Phys Technol       Date:  2007-11-01

7.  Respiratory gated irradiation system for heavy-ion radiotherapy.

Authors:  S Minohara; T Kanai; M Endo; K Noda; M Kanazawa
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-07-01       Impact factor: 7.038

8.  Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors.

Authors:  Ross I Berbeco; Steve B Jiang; Gregory C Sharp; George T Chen; Hassan Mostafavi; Hiroki Shirato
Journal:  Phys Med Biol       Date:  2004-01-21       Impact factor: 3.609

9.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

10.  Irradiation synchronized with respiration gate.

Authors:  K Ohara; T Okumura; M Akisada; T Inada; T Mori; H Yokota; M J Calaguas
Journal:  Int J Radiat Oncol Biol Phys       Date:  1989-10       Impact factor: 7.038

View more
  2 in total

1.  Amplitude-based gated phase-controlled rescanning in carbon-ion scanning beam treatment planning under irregular breathing conditions using lung and liver 4DCTs.

Authors:  Shinichiro Mori; Taku Inaniwa; Takuji Furukawa; Wataru Takahashi; Mio Nakajima; Toshiyuki Shirai; Koji Noda; Shigeo Yasuda; Naoyoshi Yamamoto
Journal:  J Radiat Res       Date:  2014-05-15       Impact factor: 2.724

2.  Development of an automatic evaluation method for patient positioning error.

Authors:  Yoshiki Kubota; Mutsumi Tashiro; Ayaka Shinohara; Satoshi Abe; Saki Souda; Ryosuke Okada; Takayoshi Ishii; Tatsuaki Kanai; Tatsuya Ohno; Takashi Nakano
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.