Literature DB >> 2777676

Irradiation synchronized with respiration gate.

K Ohara1, T Okumura, M Akisada, T Inada, T Mori, H Yokota, M J Calaguas.   

Abstract

A respiratory gating technique was developed for radiotherapy of tumors unable to remain stable due to respiration. Irradiation was started and stopped with a microwave oscillator of a linear accelerator controlled by gating signals at specific points in the respiratory cycle. This technique was tested in a phantom specially designed to simulate a patient with lung cancer and in clinical therapy for lung tumors of seven patients. A mask was used to check ventilation in the phantom and airbags were used to measure thoracoabdominal pressure in patients and in the phantom; this enabled us to detect the excursion of the tumors. Low sensitivity film for verification demonstrated the efficacy of this technique. The gated irradiation was proved to ensure more precise radiotherapy for tumors located close to the diaphragm.

Entities:  

Mesh:

Year:  1989        PMID: 2777676     DOI: 10.1016/0360-3016(89)90078-3

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  81 in total

1.  The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery.

Authors:  Marianne Falk; Tobias Larsson; Paul Keall; Byung Chul Cho; Marianne Aznar; Stine Korreman; Per Poulsen; Per Munck Af Rosenschold
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

Review 2.  Clinical evidence of particle beam therapy (proton).

Authors:  Takashi Ogino
Journal:  Int J Clin Oncol       Date:  2012-03-17       Impact factor: 3.402

3.  Design of a compensating bolus by use of exhalation CT data for covering residual motion in respiratory-gated charged-particle lung therapy: four-dimensional carbon beam dose calculation.

Authors:  Shinichiro Mori; Hiroshi Asakura; Shuhei Komatsu; Tomoyasu Yashiro; Motoki Kumagai; Susumu Kandatsu; Masayuki Baba; Masahiro Endo
Journal:  Radiol Phys Technol       Date:  2007-11-27

4.  Static versus prospective gated non-breath hold volumetric MDCT imaging of the lungs.

Authors:  Osama I Saba; Deokiee Chon; Kenneth Beck; Geoffrey McLennan; Jered Sieren; Joseph Reinhardt; Eric A Hoffman
Journal:  Acad Radiol       Date:  2005-11       Impact factor: 3.173

5.  Experimental verification of the utility of positron emitter nuclei generated by photonuclear reactions for X-ray beam monitoring in a phantom.

Authors:  Teiji Nishio; Taku Inaniwa; Kazumasa Inoue; Aya Miyatake; Keiichi Nakagawa; Kiyoshi Yoda; Takashi Ogino
Journal:  Radiat Med       Date:  2007-12-25

6.  Esophagus and spinal cord motion relative to GTV motion in four-dimensional CTs of lung cancer patients.

Authors:  Elisabeth Weiss; Krishni Wijesooriya; Paul Keall
Journal:  Radiother Oncol       Date:  2008-02-21       Impact factor: 6.280

7.  Use of dMLC for implementation of dynamic respiratory-gated radiation therapy.

Authors:  Eric W Pepin; Huanmei Wu; Hiroki Shirato
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

8.  Lung tumor tracking in fluoroscopic video based on optical flow.

Authors:  Qianyi Xu; Russell J Hamilton; Robert A Schowengerdt; Brian Alexander; Steve B Jiang
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  Stereotactic body radiotherapy for pulmonary metastases. Prognostic factors and adverse respiratory events.

Authors:  T Inoue; R-J Oh; H Shiomi; N Masai; H Miura
Journal:  Strahlenther Onkol       Date:  2013-02-20       Impact factor: 3.621

10.  Assessing four-dimensional radiotherapy planning and respiratory motion-induced dose difference based on biologically effective uniform dose.

Authors:  F-C Su; C Shi; P Mavroidis; V Goytia; R Crownover; P Rassiah-Szegedi; N Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2009-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.