Literature DB >> 20821028

Placement of pedicle screws using three-dimensional fluoroscopy-based navigation in lumbar vertebrae with axial rotation.

Wei Tian1, Zhao Lang.   

Abstract

Despite potential advantages of three-dimensional fluoroscopy-based navigation, there still remain a lot of controversies about the indications of this technology, especially whether it is worthy of being used in placement of pedicle screws in lumbar spine. However, according to the inconsistent conclusions reported in the literature and our experiences, the traditional method relying on anatomical landmarks and fluoroscopic views to guide lumbar pedicle screw insertion is unable to meet the requirement of precise screw placement. Based on our observation, screw malposition seems to occur concomitant with vertebral axial rotation which is a ubiquitous phenomenon. Three-dimensional fluoroscopy-based navigation can provide the most valuable axial images in real-time, so it may be useful for placement of pedicle screws in lumbar spine. This study was intended to evaluate the effect of axial rotation of lumbar vertebrae on the accuracy of pedicle screw placement using the traditional method, as well as assess the value of three-dimensional fluoroscopy-based navigation in improving the accuracy. Sixteen lumbar simulation models at different degrees of axial rotation (0°, 5°, 10°, and 20°), with every four assigned the same degree, were equally divided into two groups (traditional method group and three-dimensional fluoroscopy-based navigation group). Random placement of pedicle screws was carried out, followed by CT scan postoperatively. Then the outer pedicle cortex contours were depicted from reconstructed sectional pedicle images using Photoshop. The accuracy of pedicle screw placement was evaluated by determining the interrelationship between screw trajectory and pedicle cortex (quality), and measuring the shortest distance from pedicle screw axis to outer cortex of the pedicle (quantity). Eighty pedicle screws were implanted, respectively, in each group. In traditional method group, statistical difference existed in the accuracy of pedicle screw placement at different axial rotational degrees (P < 0.05). With degrees increasing, the accuracy declined. The accuracy of three-dimensional fluoroscopy-based navigation group was higher than traditional method group in vertebrae with axial rotation (P < 0.01). In qualitative evaluation, the accuracy of the two methods had statistical difference when the degree was 20°, and in quantitative evaluation, statistical difference existed in 5°, 10°, and 20° of vertebral axial rotation.

Entities:  

Mesh:

Year:  2010        PMID: 20821028      PMCID: PMC2989269          DOI: 10.1007/s00586-010-1564-x

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  24 in total

1.  Complications associated with pedicle screws.

Authors:  J E Lonstein; F Denis; J H Perra; M R Pinto; M D Smith; R B Winter
Journal:  J Bone Joint Surg Am       Date:  1999-11       Impact factor: 5.284

Review 2.  The use of pedicle-screw internal fixation for the operative treatment of spinal disorders.

Authors:  R W Gaines
Journal:  J Bone Joint Surg Am       Date:  2000-10       Impact factor: 5.284

3.  In vivo accuracy of thoracic pedicle screws.

Authors:  P J Belmont; W R Klemme; A Dhawan; D W Polly
Journal:  Spine (Phila Pa 1976)       Date:  2001-11-01       Impact factor: 3.468

4.  Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases.

Authors:  Jonathan S Hott; Vivek R Deshmukh; Jeffrey D Klopfenstein; Volker K H Sonntag; Curtis A Dickman; Robert F Spetzler; Stephen M Papadopoulos
Journal:  Neurosurgery       Date:  2004-05       Impact factor: 4.654

5.  Pedicle screw placement accuracy: a meta-analysis.

Authors:  Victor Kosmopoulos; Constantin Schizas
Journal:  Spine (Phila Pa 1976)       Date:  2007-02-01       Impact factor: 3.468

6.  [Vertebral osteosynthesis using metal plates. Its different uses (author's transl)].

Authors:  R Roy-Camille; G Saillant; D Berteaux; S Marie-Anne; P Mamoudy
Journal:  Chirurgie       Date:  1979

7.  Pedicle morphology in thoracic adolescent idiopathic scoliosis: is pedicle fixation an anatomically viable technique?

Authors:  M F O'Brien; L G Lenke; S Mardjetko; T G Lowe; Y Kong; K Eck; D Smith
Journal:  Spine (Phila Pa 1976)       Date:  2000-09-15       Impact factor: 3.468

8.  Thoracic pedicle screw fixation in spinal deformities: are they really safe?

Authors:  S I Suk; W J Kim; S M Lee; J H Kim; E R Chung
Journal:  Spine (Phila Pa 1976)       Date:  2001-09-15       Impact factor: 3.468

9.  Internal fixation of the lumbar spine with pedicle screw plating.

Authors:  R Roy-Camille; G Saillant; C Mazel
Journal:  Clin Orthop Relat Res       Date:  1986-02       Impact factor: 4.176

10.  The effect of transpedicular screw misplacement on late spinal stability.

Authors:  S C Açikbaş; F Y Arslan; M R Tuncer
Journal:  Acta Neurochir (Wien)       Date:  2003-11       Impact factor: 2.216

View more
  7 in total

1.  Accuracy of lower cervical pedicle screw placement with assistance of distinct navigation systems: a human cadaveric study.

Authors:  Wei Tian; Yajun Liu; Shan Zheng; Yanwei Lv
Journal:  Eur Spine J       Date:  2012-09-18       Impact factor: 3.134

2.  Accuracy of pedicle screw insertion by AIRO® intraoperative CT in complex spinal deformity assessed by a new classification based on technical complexity of screw insertion.

Authors:  S Rajasekaran; Manindra Bhushan; Siddharth Aiyer; Rishi Kanna; Ajoy Prasad Shetty
Journal:  Eur Spine J       Date:  2018-01-09       Impact factor: 3.134

3.  Three-dimensional fluoroscopic navigation versus fluoroscopy-guided placement of pedicle screws in L4-L5-S1 fixation: single-centre experience of pedicular accuracy and S1 cortical fixation of 810 screws.

Authors:  Manuel García-Fantini; Ricardo De Casas
Journal:  J Spine Surg       Date:  2018-12

4.  Screw placement accuracy for minimally invasive transforaminal lumbar interbody fusion surgery: a study on 3-d neuronavigation-guided surgery.

Authors:  Jorge Torres; Andrew R James; Marjan Alimi; Apostolos John Tsiouris; Christian Geannette; Roger Härtl
Journal:  Global Spine J       Date:  2012-09

5.  The effect of lateral wall perforation on screw pull-out strength: a cadaveric study.

Authors:  Nan Li; Da He; Yonggang Xing; Yanwei Lv; Wei Tian
Journal:  J Orthop Surg Res       Date:  2015-01-24       Impact factor: 2.359

Review 6.  Is the diagnostic radiological image an underutilised resource? Exploring the literature.

Authors:  William A S Cox; Penelope Cavenagh; Fernando Bello
Journal:  Insights Imaging       Date:  2019-02-06

7.  Combined 3D rapid prototyping and computer navigation facilitate surgical treatment of congenital scoliosis: A case report and description of technique.

Authors:  Qiu-Ju Li; Tong Yu; Lian-Hua Liu; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.