RATIONALE: This study describes the technique of combined Orbic 3D navigation (O3DN) and 3D rapid prototyping (3DRP) to assist surgical correction of congenital scoliosis. PATIENT CONCERNS: A 12-year-old boy with congenital scoliosis. His father brought him to our hospital upon noticing the boy's asymmetry of the trunk. DIAGNOSES: Congenital scoliosis.
INTERVENTIONS: O3DN and 3DRP were used to assist correction surgery in this patient. OUTCOMES: The Cobb angle of segmental scoliosis (T8-L2) was 46.9° preoperatively and 2.3° at the last postoperative follow-up; correction was 95.1%. The average segmental kyphosis (T5-T12) was 45.2° preoperatively and 18.6° at the postoperative follow-up; correction was 58.9%. The preoperative sagittal imbalance of 56.2 mm was improved to 9.7 mm. The mean distance between the center sacral vertical line and the C7 plumb line was reduced from 5.7 to 4.1 mm. Operative time and bleeding volume was impressively little, with no misplacement of pedicle screws or other surgical complications. LESSONS: Combined 3DRP and O3DN helped achieve satisfactory correction for this case of congenital scoliosis. The application of 3DRP aided by O3DN in surgical treatment of congenital scoliosis can reduce operative time, lessen blood loss, reduce screw misplacement, and avoid neurovascular damage. However, patients' hospital costs were greater. Our lessons learnt are that the relative position between the tracker and the pedicle must be static to ensure the accuracy of the whole system during the entire operation.

Entities:  

Mesh:

Year:  2018        PMID: 30075572      PMCID: PMC6081065          DOI: 10.1097/MD.0000000000011701

Source DB:  PubMed          Journal:  Medicine (Baltimore)        ISSN: 0025-7974            Impact factor:   1.817


Introduction

Congenital scoliosis (CS) is a 3-dimensional (3D) malformation of the spine. In the axial, sagittal, and coronal planes, respectively, CS mainly features vertebral rotation, variations in alignment, and deviations.[ The goal of surgical treatment in CS is to obtain satisfactory correction of the deformities, while minimizing complications. Practically, the more accurate the implantations of the pedicle screws during surgery for CS, the less probability there will be of injury to neurovascular structures. In the past, screw insertion by freehand achieved outcomes that were considered acceptable.[ However, as the angle of vertebral rotation increases, so does the difficulty of screw implantation,[ and the malposition rate of freehand pedicle screw placement is 1.7% to 15.7%.[ Measures to facilitate pedicle screw implantation in CS correction include guiding devices,[ computer-assisted surgery,[ robot-assisted surgery,[ and 3D rapid prototyping.[ Yet, the rates of screw malposition using these techniques remain too high, at 5.6% to 11.4%.[ Three-D rapid prototyping (3DRP) provides preoperative simulation and modeling of the spinal malformation, and intraoperative computer navigation allows the operator to visualize in real time the position and trajectory of the screw. In the present study, we combined 3DRP and intraoperative computer navigation (Orbic 3D navigation; O3DN) to optimally facilitate pedicle screw insertion and CS correction and minimize surgical risk. To our best knowledge, this is the first description in the literature of the use of this combined technology for the surgical treatment of CS.

Ethics

The Ethics Committee of Second Hospital of Jilin University, Changchun, China approved this report. The patient provided written informed consent for this report, and his information has been anonymized.

Case report

Patient characteristics

The patient was a 12-year-old boy, whose father brought him to the hospital upon noticing non-symmetry of the trunk (Table 1). The boy was otherwise healthy and reported no discomfort. Examination revealed a razor back deformity on the right side. The patient had no sensory disturbance, and his muscle force and tension and knee and Achilles tendon reflexes were normal. He tested negative for the Hoffman sign, Babinski reflex, Chaddock reflex, patellar clonus, Lasègue test, and Bragard sign.
Table 1

Patient characteristics.

Patient characteristics.

Imaging examination

X-ray imaging showed segmental scoliosis (T8-L2) of 46.9°, and segmental kyphosis (T5-T12) of 45.2° (Fig. 1A). The sagittal imbalance distance was 56.2 mm. The distance between the center sacral vertical line and the C7 plumb line was 5.7 mm. The upper end, apex, lower end, and stable vertebrae were, respectively, T8, T11, L2, and T7 (Table 1). Congenital fusion existed in T1-2, T4-6, T8-9, and L1-2. The patient had a Risser grade of V.
Figure 1

Anterior-posterior and lateral standing full-length spinal x-rays were obtained (A) preoperatively, (B) postoperatively, and (C) at the final follow-up visit.

Anterior-posterior and lateral standing full-length spinal x-rays were obtained (A) preoperatively, (B) postoperatively, and (C) at the final follow-up visit. Nervous-system magnetic resonance imaging displayed a tethered cord, syringomyelia in the thoracic spinal cord, and diastematomyelia. Ultrasonic cardiography and pulmonary function tests were performed to evaluate whether heart or lung disease was present. Results of the electromyography of both lower extremities showed that the sensory and motor nerve conduction velocity of the lower extremities was normal, and the H reflex of the double tibial nerve was normal. The primary diagnosis was CS, spinal deformity (instrumented vertebra/segmentation defects), and diastematomyelia.

Preoperative preparation

The preoperative computed tomography (CT) image of the whole spine was scanned and the graphic data was recorded in the disc. The disc could be recognized by a computer navigation system. The diameter and length of the pedicle was precisely measured at the navigation workstation. In addition, the disc was entered into a 3D printer (AFS-450, Beijing Long Yuan Automated Fabrication System, Beijing, China), and an equal proportion model was produced by fused deposition modeling software (Fig. 2).
Figure 2

The 3DRP model of the whole spine, which allowed the surgeon understanding of the details of the deformed structures at multiple angles.

The 3DRP model of the whole spine, which allowed the surgeon understanding of the details of the deformed structures at multiple angles.

Surgical technique

The procedure was performed with the patient prone and under general anesthesia. The posterior structures of the lesion segments were exposed. The Navigation System workstation was started, and SpineMap 3D 2.0 software was chosen (Stryker Navigation, Kalamazoo, MI). A patient tracker (Stryker Leibinger GmbH, Freiburg, Germany) was fixed onto the vertebra spinous process. The instrument tracker, the patient tracker, and the system's C-arm tracker were activated. At the center of the segmental lesion intended to receive the pedicle screw implant, 190° scanning was performed, and 3D images of the lesion were obtained. The point of the needle and its trajectory were guided by navigation (Fig. 3). The anatomic structure of the lesion was easily identified by observing the 3DRP model (Fig. 2). Titanium rods were installed and the nut of the pedicle screw-rod system was tightened. Intraoperative frontal and lateral radiographs were taken to check the position of the implanted screws. Intraoperative spinal cord monitoring was performed, including somatosensory evoked potentials and motor evoked potentials.
Figure 3

The navigation monitor provided a dynamic display of the trajectories of surgical instruments during screw implantation.

The navigation monitor provided a dynamic display of the trajectories of surgical instruments during screw implantation. Postoperatively, the patient used a brace to maintain stability for 3 months. The precision of the pedicle screws was determined by CT scans, and the screw position was evaluated as described by Ughwanogho et al.[ Total spine x-rays were taken after the surgery and at the last follow-up at 28 months (Fig. 1B and C). The clinical picture was also collected before and after surgery (Fig. 4A and B). The following data were gathered retrospectively from the medical records: operative time, bleeding volume, and surgical complications.
Figure 4

Clinical pictures of the patient (A) preoperatively, and (B) postoperatively.

Clinical pictures of the patient (A) preoperatively, and (B) postoperatively. The neurological function was intact postoperatively. No screw loosening, pseudarthrosis formation, or curve progression was found during the follow-up period. At the last follow-up at 28 months, the Cobb angle of segmental scoliosis was 2.3°, and correction was 95.1%; the segmental kyphosis (T5-T12) was 18.6° with 58.9% correction. The mean distance between the center sacral vertical line and the C7 plumb line was reduced from 56.2 to 9.7 mm, and the sagittal imbalance of 56.2 mm was improved to 9.7 mm (Table 2). The operative time was 193 minutes, and the bleeding volume was 801 mL (Table 1).
Table 2

Correction in the coronal and sagittal planes.

Correction in the coronal and sagittal planes.

Discussion

Currently, the primary treatment method for CS is posterior spinal fixation with pedicle screw.[ Due to screw misplacement is a major complication during surgery. To facilitate the success of the operation and minimize surgical risks, we combined the advantages of 3DRP technology and computer navigation. A 12-year-old boy with congenital scoliosis underwent corrective surgery with the assistance of O3DN and 3DRP. Segmental scoliosis (T8-L2), kyphosis (T5-T12) and sagittal imbalance were improved effectively; In addition, with no misplacement of pedicle screws or other surgical complications. In our study, none of the pedicle screws were misplaced, and there was no neurologic complication. The main curve correction was 95.1%, which is better than that reported by Quan and Gibson[ (69.9%) or Fatyga et al.[ (70%). In the present case, we attribute the accuracy of pedicle screw placement and good correction rate to the combined application of 3DRP and O3DN. In our opinion, this technology will help the surgeon avoid nerve compromise and pedicle damage and enhance stability of the spine. In the present case, not including the time to make the 3D print model prior to surgery, the operative time was 193 minutes using 3DRP and O3DN, which is similar to that reported by Yang et al,[ although I consider that our operation is more complex. Our positive outcome was probably due to the full understanding of the deformity of the spinal structures afforded by the 3D models that were created preoperatively. We were thus able to identify intraoperatively the entry point quickly, and the computer navigation guided the trajectory. In addition, there is usually a lot of blood loss during deformity corrective surgery.[ It is important for doctors to take effective measures to reduce bleeding during surgery, as allogeneic blood transfusion risks infection and hemodynamic complications. In this study, the blood loss was 801 mL, and we attribute this good result to the combined 3DRP and O3DN method and much shorter operative time. Loosening of the pedicle screws is a common complication of posterior spinal fusion and fixation in spinal surgery. Ohtori et al[ and Morr et al[ reported rates of screw loosening of 7% and 19.5%, respectively. Screw loosening is associated with several complications, including screw breakage, pseudarthrosis, and even loose correction.[ In the present case, no pedicle screw loosening was observed during the follow-up. In my view, this positive outcome was due to the simulated surgery using 3D printing technology, screw implantation aided by computer navigation, and the use of a brace to ensure fusion and maintain stability for 3 months postoperatively. When the right pedicle channel was prepared for T10, the surgeon suspected the inaccuracy of the navigation image, and confirmed the drift of the navigation image after comparing it with the anatomical structure of the 3D print model. During the operation, the patient tracker was re-fixed, the surgical instruments were re-calibrated and the lesion images were scanned again. Finally, the screws were implanted under precise navigation. We consider that the movement of the patient tracker leads to inaccurate navigation intraoperative. In our opinion, if we find that the navigation is not accurate intraoperative, we should find out the reason and avoid blind pedicle screw planting so as to prevent the occurrence of complications such as nerve injury. Although perfect results were achieved in this case, there are also some limitations. First, the application of 3DRP and O3DN was costly, and increased the patients’ hospitalization charges. In addition, the follow-up duration was relatively short and longer observation periods are needed. To assess the effectiveness of combined 3DRP and O3DN technology for patients with CS, costs of the procedure to the patient should be reduced, and follow-ups should be longer.

Conclusion

Herein we demonstrated that preoperative 3DRP combined with intraoperative O3DN could facilitate a good therapeutic effect for surgical treatment of CS. Our experience is that during the entire operation, the relative position between the tracker and the pedicle must be static to ensure the accuracy of the whole system. The application of this combined method in CS should decrease the operative time, rate of screw loosening, risk of screw misplacement, and achieve a satisfactory correction. Therefore, preoperative 3DRP combined with intraoperative O3DN to treat CS is safe and efficacious, although it may increase the hospital cost of the patient.

Acknowledgments

We gratefully acknowledge the cooperation of the doctors and nurses in the operating room.

Author contributions

Data curation: Tong Yu. Validation: Lian-Hua Liu. Writing – original draft: Qiu-Ju Li. Writing – review & editing: Jian-Wu Zhao.
  20 in total

1.  Improved accuracy of computer-assisted cervical pedicle screw insertion.

Authors:  Yoshihisa Kotani; Kuniyoshi Abumi; Manabu Ito; Akio Minami
Journal:  J Neurosurg       Date:  2003-10       Impact factor: 5.115

Review 2.  Complications of pedicle screw fixation in scoliosis surgery: a systematic review.

Authors:  John M Hicks; Amit Singla; Francis H Shen; Vincent Arlet
Journal:  Spine (Phila Pa 1976)       Date:  2010-05-15       Impact factor: 3.468

3.  Predicting operative blood loss during spinal fusion for adolescent idiopathic scoliosis.

Authors:  Marc N Ialenti; Baron S Lonner; Kushagra Verma; Laura Dean; Antonio Valdevit; Thomas Errico
Journal:  J Pediatr Orthop       Date:  2013-06       Impact factor: 2.324

4.  Accuracy and postoperative assessment of pedicle screw placement during scoliosis surgery with computer-assisted navigation: a meta-analysis.

Authors:  Wei Tian; Cheng Zeng; Yan An; Chao Wang; Yajun Liu; Jianing Li
Journal:  Int J Med Robot       Date:  2016-03-08       Impact factor: 2.547

5.  The efficacy and complications of posterior hemivertebra resection.

Authors:  Jianguo Zhang; Wang Shengru; Guixing Qiu; Bin Yu; Wang Yipeng; Keith D K Luk
Journal:  Eur Spine J       Date:  2011-02-12       Impact factor: 3.134

6.  Accuracy and safety assessment of pedicle screw placement using the rapid prototyping technique in severe congenital scoliosis.

Authors:  Zi-Xiang Wu; Lu-Yu Huang; Hong-Xun Sang; Zhen-Sheng Ma; Shi-Yong Wan; Geng Cui; Wei Lei
Journal:  J Spinal Disord Tech       Date:  2011-10

7.  Comparison of teriparatide and bisphosphonate treatment to reduce pedicle screw loosening after lumbar spinal fusion surgery in postmenopausal women with osteoporosis from a bone quality perspective.

Authors:  Seiji Ohtori; Gen Inoue; Sumihisa Orita; Kazuyo Yamauchi; Yawara Eguchi; Nobuyasu Ochiai; Shunji Kishida; Kazuki Kuniyoshi; Yasuchika Aoki; Junichi Nakamura; Tetsuhiro Ishikawa; Masayuki Miyagi; Hiroto Kamoda; Miyako Suzuki; Gou Kubota; Yoshihiro Sakuma; Yasuhiro Oikawa; Kazuhide Inage; Takeshi Sainoh; Masashi Takaso; Tomoaki Toyone; Kazuhisa Takahashi
Journal:  Spine (Phila Pa 1976)       Date:  2013-04-15       Impact factor: 3.468

8.  [Outcome after surgical treatment of idiopathic scoliosis using three- dimensional correction with spondylodesis].

Authors:  Marek Fatyga; Bogdan Kłapeć; Piotr Majcher; Andrzej Skwarcz
Journal:  Ortop Traumatol Rehabil       Date:  2005-06-30

9.  Accuracy of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis in the pediatric population.

Authors:  Jeremy J Macke; Raymund Woo; Laura Varich
Journal:  J Robot Surg       Date:  2016-04-12

10.  Surgical outcomes and complications of posterior hemivertebra resection in children younger than 5 years old.

Authors:  Jianwei Guo; Jianguo Zhang; Shengru Wang; Yanbin Zhang; Yang Yang; Xinyu Yang; Lijuan Zhao
Journal:  J Orthop Surg Res       Date:  2016-04-25       Impact factor: 2.359

View more
  10 in total

1.  A novel screw view model of 3D navigation for upper cervical pedicle screw placement: A case report.

Authors:  Jianwu Zhao; Lili Yang; Shuang Zheng; Yang Qu; Xiwen Zhang; Mingyang Kang; Rongpeng Dong; Xin Zhao; Tong Yu
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

2.  Multimodal intraoperative monitoring during surgical correction of scoliosis to avoid neurologic damage.

Authors:  Tong Yu; Qiu-Ju Li; Xi-Wen Zhang; Yao Wang; Qi-Yao Jiang; Xiu-Jie Zhu; Zhen-De Jiang; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2019-04       Impact factor: 1.817

3.  Technology of percutaneous cannulated screw implantation using screw view model of navigation in Garden type I of femoral neck fracture: A case report.

Authors:  Tong Yu; Bao-Ming Yuan; Xi-Wen Zhang; Dong-Sheng Wang; Yi-Kun Jiang; Rong-Peng Dong; Ming-Yang Kang; Xin Zhao; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

4.  Combined navigated drilling and arthroscopy facilitate minimally invasive surgical treatment of ulnar-radial joint dislocation caused by epiphyseal premature closure: A case report.

Authors:  Tong Yu; Bao-Ming Yuan; Yi-Kun Jiang; Qi-Wei Li; Qian Wang; Li-Heng Kang; Xi-Wen Zhang; Dan-Kai Wu; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

5.  Screw view model of navigation in posterior corrective surgery for adolescent idiopathic scoliosis: A case report and technique note.

Authors:  Tong Yu; Lili Yang; Shuang Zheng; Yang Qu; Xiwen Zhang; Mingyang Kang; Rongpeng Dong; Jianwu Zhao
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

6.  Navigation-guided percutaneous pelvic cementoplasty for metastatic bone pain: A case report.

Authors:  Ji Hyeon Lee; In Young Kim; Young Don Kim; So Young Lee; Jin Yong Jung
Journal:  Medicine (Baltimore)       Date:  2021-04-16       Impact factor: 1.817

7.  Depth Vision-Based Assessment of Bone Marrow Mesenchymal Stem Cell Differentiation Capacity in Patients with Congenital Scoliosis.

Authors:  Ning Liang; Qiwen Zhang; Bin He
Journal:  J Healthc Eng       Date:  2022-04-12       Impact factor: 3.822

8.  Accurate fixation of complicated comminuted femur fracture with customized LCP referencing a life-size 3D-printed model: a case report.

Authors:  He Liu; Baoming Yuan; Tong Yu; Guangkai Ren; Yan Zhang; Yang Wu; Yadong Liu; Chuangang Peng; Dankai Wu
Journal:  Ann Transl Med       Date:  2020-04

9.  A novel computer navigation model guided unilateral percutaneous vertebroplasty for vertebral compression fracture: A case report.

Authors:  Hao-Tian Xu; Shuang Zheng; Ming-Yang Kang; Tong Yu; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2020-10-30       Impact factor: 1.817

10.  Combined 3-dimensional printing model and 3-dimensional fluoroscopic navigation to assist C2 pedicle screw insertion: A case report.

Authors:  Hao-Tian Xu; Shuang Zheng; Rong-Peng Dong; Tong Yu; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2020-10-23       Impact factor: 1.817

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.