Literature DB >> 14628199

The effect of transpedicular screw misplacement on late spinal stability.

S C Açikbaş1, F Y Arslan, M R Tuncer.   

Abstract

BACKGROUND: In this article the authors investigated the consequences of misplaced thoracolumbar pedicle screws on late spinal stability.
METHOD: This study consisted of 16 patients with screws in the proper position (Group A) and a further 16 patients with screw misplacement (Group B) who had previously undergone transpedicular screw fixation following thoracolumbar injury. The authors retrospectively evaluated the bone fusion, anterior height of the fractured vertebrae and the kyphotic deformity on postoperative early neutral, and on postoperative long-term neutral and dynamic radiographs in both groups. The results and in addition a back pain questionnaire were compared within each group, and also between groups A and B.
FINDINGS: The decreased anterior height of the fractured vertebrae and the increased degree of kyphosis on postoperative early radiographs in group B demonstrated that the correction of the deformity was inadequate in patients with screw misplacement. Furthermore, an additional increase in the degree of kyphosis on long-term neutral radiographs indicated a significant progression in late kyphotic deformity in group B, whereas it was not seen in group A. The evidence of significant motion on neutral-flexion and flexion-extension long-term radiographs demonstrated impaired stability in group B, whilst it was only evident in neutral-flexion radiographs in group A. Moreover, moderate to severe back pain was commonly reported by patients in group B and correlated with lack of bony fusion and significant motion.
INTERPRETATION: The authors conclude that the screw misplacement decreased the original spinal stability provided by the instrumentation. Therefore, correct placement of pedicle screws is required to maintain long-term spinal stability.

Entities:  

Mesh:

Year:  2003        PMID: 14628199     DOI: 10.1007/s00701-003-0116-0

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  15 in total

1.  A preliminary study of reliability of impedance measurement to detect iatrogenic initial pedicle perforation (in the porcine model).

Authors:  Ciaran Bolger; C Carozzo; T Roger; Linda McEvoy; Jabir Nagaria; Gerard Vanacker; Maurice Bourlion
Journal:  Eur Spine J       Date:  2005-10-13       Impact factor: 3.134

2.  Electrical conductivity measurement: a new technique to detect iatrogenic initial pedicle perforation.

Authors:  Ciaran Bolger; Michael O Kelleher; Linda McEvoy; M Brayda-Bruno; A Kaelin; J-Y Lazennec; J-C Le Huec; C Logroscino; P Mata; P Moreta; G Saillant; R Zeller
Journal:  Eur Spine J       Date:  2007-06-30       Impact factor: 3.134

Review 3.  [Deformities following spinal injury at the thoracolumbar junction].

Authors:  S Schmidt; K-D Thomann; M Rauschmann
Journal:  Orthopade       Date:  2010-03       Impact factor: 1.087

4.  Placement of pedicle screws using three-dimensional fluoroscopy-based navigation in lumbar vertebrae with axial rotation.

Authors:  Wei Tian; Zhao Lang
Journal:  Eur Spine J       Date:  2010-09-06       Impact factor: 3.134

5.  Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study.

Authors:  Akira Matsuoka; Tomoaki Toyone; Ichiro Okano; Yoshifumi Kudo; Koji Ishikawa; Hiroshi Maruyama; Tomoyuki Ozawa; Toshiyuki Shirahata; Katsunori Inagaki
Journal:  BMC Musculoskelet Disord       Date:  2022-07-05       Impact factor: 2.562

6.  Posterior pedicle screw fixation with supplemental laminar hook fixation for the treatment of thoracolumbar burst fractures.

Authors:  Stéphane Leduc; Jean-Marc Mac-Thiong; Gilles Maurais; Alain Jodoin
Journal:  Can J Surg       Date:  2008-02       Impact factor: 2.089

7.  Accuracy of Pedicle Screw Placement Comparing an Electronic Conductivity Device and a Multi-axis Angiography Unit with C-arm Fluoroscopy in Lumbar Fixation Surgery for Safety.

Authors:  Hiroto Kageyama; Shinichi Yoshimura; Kotaro Tatebayashi; Tomoko Iida; Kiyofumi Yamada
Journal:  Neurol Med Chir (Tokyo)       Date:  2021-03-31       Impact factor: 1.742

8.  Intraoperative 3-dimensional imaging (O-arm) for assessment of pedicle screw position: Does it prevent unacceptable screw placement?

Authors:  Jonathan N Sembrano; David W Polly; Charles Gerald T Ledonio; Edward Rainier G Santos
Journal:  Int J Spine Surg       Date:  2012-12-01

9.  Intraoperative three-dimensional fluoroscopy after transpedicular positioning of Kirschner-wire versus conventional intraoperative biplanar fluoroscopic control: A retrospective study of 345 patients and 1880 pedicle screws.

Authors:  Ghassan Kerry; Claus Ruedinger; Hans-Herbert Steiner
Journal:  J Craniovertebr Junction Spine       Date:  2014-07

10.  Pedicle violation and Navigational errors in pedicle screw insertion using the intraoperative O-arm: A preliminary report.

Authors:  Jacob E Mathew; Kelvin Mok; Benoit Goulet
Journal:  Int J Spine Surg       Date:  2013-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.