Literature DB >> 20817162

Mechanisms of initial endplate failure in the human vertebral body.

Aaron J Fields1, Gideon L Lee, Tony M Keaveny.   

Abstract

Endplate failure occurs frequently in osteoporotic vertebral fractures and may be related to the development of high tensile strain. To determine whether the highest tensile strains in the vertebra occur in the endplates, and whether such high tensile strains are associated with the material behavior of the intervertebral disc, we used micro-CT-based finite element analysis to assess tissue-level strains in 22 elderly human vertebrae (81.5 ± 9.6 years) that were compressed through simulated intervertebral discs. In each vertebra, we compared the highest tensile and compressive strains across the different compartments: endplates, cortical shell, and trabecular bone. The influence of Poisson-type expansion of the disc on the results was determined by compressing the vertebrae a second time in which we suppressed the Poisson expansion. We found that the highest tensile strains occurred within the endplates whereas the highest compressive strains occurred within the trabecular bone. The ratio of strain to assumed tissue-level yield strain was the highest for the endplates, indicating that the endplates had the greatest risk of initial failure. Suppressing the Poisson expansion of the disc decreased the amount of highly tensile-strained tissue in the endplates by 79.4 ± 11.3%. These results indicate that the endplates are at the greatest risk of initial failure due to the development of high tensile strains, and that such high tensile strains are associated with the Poisson expansion of the disc. We conclude that initial failure of the vertebra is associated with high tensile strains in the endplates, which in turn are influenced by the material behavior of the disc.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20817162      PMCID: PMC2991488          DOI: 10.1016/j.jbiomech.2010.08.002

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  49 in total

Review 1.  The vertebral end-plate: what do we know?

Authors:  R J Moore
Journal:  Eur Spine J       Date:  2000-04       Impact factor: 3.134

2.  Mapping the structural properties of the lumbosacral vertebral endplates.

Authors:  J P Grant; T R Oxland; M F Dvorak
Journal:  Spine (Phila Pa 1976)       Date:  2001-04-15       Impact factor: 3.468

3.  Determination of vertebral endplate deformation under load using micro-computed tomography.

Authors:  P A Hulme; S J Ferguson; S K Boyd
Journal:  J Biomech       Date:  2007-10-29       Impact factor: 2.712

4.  Mechanical and morphological variation of the human lumbar vertebral cortical and trabecular bone.

Authors:  M E Roy; J Y Rho; T Y Tsui; N D Evans; G M Pharr
Journal:  J Biomed Mater Res       Date:  1999-02

5.  A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models.

Authors:  B van Rietbergen; H Weinans; R Huiskes; A Odgaard
Journal:  J Biomech       Date:  1995-01       Impact factor: 2.712

6.  Systems identification for material properties of the intervertebral joint.

Authors:  H S Lin; Y K Liu; G Ray; P Nikravesh
Journal:  J Biomech       Date:  1978       Impact factor: 2.712

Review 7.  Identification of vertebral fractures: an update.

Authors:  L Ferrar; G Jiang; J Adams; R Eastell
Journal:  Osteoporos Int       Date:  2005-05-03       Impact factor: 4.507

8.  The effect of nucleotomy on lumbar spine mechanics in compression and shear loading.

Authors:  H Frei; T R Oxland; G C Rathonyi; L P Nolte
Journal:  Spine (Phila Pa 1976)       Date:  2001-10-01       Impact factor: 3.468

9.  Influence of bone volume fraction and architecture on computed large-deformation failure mechanisms in human trabecular bone.

Authors:  Grant Bevill; Senthil K Eswaran; Atul Gupta; Panayiotis Papadopoulos; Tony M Keaveny
Journal:  Bone       Date:  2006-08-10       Impact factor: 4.398

10.  Vertebral fractures usually affect the cranial endplate because it is thinner and supported by less-dense trabecular bone.

Authors:  F-D Zhao; P Pollintine; B D Hole; M A Adams; P Dolan
Journal:  Bone       Date:  2008-11-11       Impact factor: 4.398

View more
  24 in total

1.  Association of vertebral endplate microstructure with bone strength in men and women.

Authors:  MeiLissa McKay; Timothy M Jackman; Amira I Hussein; Ali Guermazi; Jingjiang Liu; Elise F Morgan
Journal:  Bone       Date:  2019-11-06       Impact factor: 4.398

2.  Vertebral fragility and structural redundancy.

Authors:  Aaron J Fields; Shashank Nawathe; Senthil K Eswaran; Michael G Jekir; Mark F Adams; Panayiotis Papadopoulos; Tony M Keaveny
Journal:  J Bone Miner Res       Date:  2012-10       Impact factor: 6.741

3.  Is bone density associated with intervertebral disc pressure in healthy and degenerated discs?

Authors:  Paul M Fein; Alexander DelMonaco; Timothy M Jackman; Cameron Curtiss; Ali Guermazi; Glenn D Barest; Elise F Morgan
Journal:  J Biomech       Date:  2017-09-04       Impact factor: 2.712

4.  Micromechanics of the human vertebral body for forward flexion.

Authors:  Haisheng Yang; Shashank Nawathe; Aaron J Fields; Tony M Keaveny
Journal:  J Biomech       Date:  2012-06-16       Impact factor: 2.712

5.  Seeing double: a comparison of microstructure, biomechanical function, and adjacent disc health between double- and single-layer vertebral endplates.

Authors:  Aaron J Fields; Francisco Sahli; Azucena G Rodriguez; Jeffrey C Lotz
Journal:  Spine (Phila Pa 1976)       Date:  2012-10-01       Impact factor: 3.468

6.  Quantitative, 3D Visualization of the Initiation and Progression of Vertebral Fractures Under Compression and Anterior Flexion.

Authors:  Timothy M Jackman; Amira I Hussein; Cameron Curtiss; Paul M Fein; Anderson Camp; Lidia De Barros; Elise F Morgan
Journal:  J Bone Miner Res       Date:  2015-12-24       Impact factor: 6.741

7.  Effective modulus of the human intervertebral disc and its effect on vertebral bone stress.

Authors:  Haisheng Yang; Michael G Jekir; Maxwell W Davis; Tony M Keaveny
Journal:  J Biomech       Date:  2016-02-27       Impact factor: 2.712

Review 8.  Third-generation percutaneous vertebral augmentation systems.

Authors:  Daniele Vanni; Renato Galzio; Anna Kazakova; Andrea Pantalone; Giovanni Grillea; Marcello Bartolo; Vincenzo Salini; Vincenzo Magliani
Journal:  J Spine Surg       Date:  2016-03

9.  Significance of cartilage endplate within herniated disc tissue.

Authors:  Polly Lama; Uruj Zehra; Christian Balkovec; Henry A Claireaux; Luke Flower; Ian J Harding; Patricia Dolan; Michael A Adams
Journal:  Eur Spine J       Date:  2014-06-20       Impact factor: 3.134

10.  Differences in Trabecular Microarchitecture and Simplified Boundary Conditions Limit the Accuracy of Quantitative Computed Tomography-Based Finite Element Models of Vertebral Failure.

Authors:  Amira I Hussein; Daniel T Louzeiro; Ginu U Unnikrishnan; Elise F Morgan
Journal:  J Biomech Eng       Date:  2018-02-01       Impact factor: 2.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.