Literature DB >> 7852443

A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models.

B van Rietbergen1, H Weinans, R Huiskes, A Odgaard.   

Abstract

The apparent mechanical behavior of trabecular bone depends on properties at the tissue or trabecular level. Many investigators have attempted to determine trabecular tissue properties and loading. However, accuracy and applicability of all methods reported are limited. The small size of the trabeculae and a possible size effect are complicating factors when using traditional testing methods on single trabeculae. Other methods reported, using models that describe the trabecular structure, are of limited value because they consider bone as a repetitive structure in order to describe a reasonably large region of bone. The present study introduces a new finite-element method strategy that enables analysis of reasonably large regions of trabecular bone in full detail. The method uses three-dimensional serial reconstruction techniques to construct a large-scale FE model, by directly converting voxels to elements. A 5 mm cube of trabecular bone was modeled in this way, resulting in a FE model that consists of 296,679 elements. Special strategies were developed to solve the set of equations that results from the FE approach. Using this model in combination with experimental apparent data taken from the literature, the upper and lower boundaries for the tissue modulus were calculated to be 10.1 and 2.23 GPa, respectively. From the local stress and strain distributions it was concluded that the deformation mode of the trabeculae in the present cube was predominantly in bending. It was concluded that the method developed offers new perspectives for the study of trabecular bone.

Entities:  

Mesh:

Year:  1995        PMID: 7852443     DOI: 10.1016/0021-9290(95)80008-5

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  131 in total

Review 1.  If bone is the answer, then what is the question?

Authors:  R Huiskes
Journal:  J Anat       Date:  2000-08       Impact factor: 2.610

2.  Changes in trabecular and cortical bone microarchitecture at peripheral sites associated with 18 months of teriparatide therapy in postmenopausal women with osteoporosis.

Authors:  H M Macdonald; K K Nishiyama; D A Hanley; S K Boyd
Journal:  Osteoporos Int       Date:  2010-05-11       Impact factor: 4.507

3.  Bone microarchitecture assessment: current and future trends.

Authors:  Ralph Müller
Journal:  Osteoporos Int       Date:  2003-08-29       Impact factor: 4.507

4.  The three-dimensional microstructure of the trabecular bone in the mandible.

Authors:  H S Moon; Y Y Won; K D Kim; A Ruprecht; H J Kim; H K Kook; M K Chung
Journal:  Surg Radiol Anat       Date:  2004-12       Impact factor: 1.246

5.  Minimum solid area models applied to the prediction of Young's modulus for cancellous bone.

Authors:  K U O'Kelly; A J Carr; B A O McCormack
Journal:  J Mater Sci Mater Med       Date:  2003-04       Impact factor: 3.896

6.  Multi-scale modelling of elastic moduli of trabecular bone.

Authors:  Elham Hamed; Iwona Jasiuk; Andrew Yoo; Yikhan Lee; Tadeusz Liszka
Journal:  J R Soc Interface       Date:  2012-01-25       Impact factor: 4.118

7.  An experimentally validated micromechanical model of a rat vertebra under compressive loading.

Authors:  Naomi Tsafnat; Stephen Wroe
Journal:  J Anat       Date:  2010-08-31       Impact factor: 2.610

8.  Variations in morphological and biomechanical indices at the distal radius in subjects with identical BMD.

Authors:  Galateia J Kazakia; Andrew J Burghardt; Thomas M Link; Sharmila Majumdar
Journal:  J Biomech       Date:  2010-11-10       Impact factor: 2.712

9.  Optimal sample volumes of human trabecular bone in μCT analysis within vertebral body and femoral head.

Authors:  Xin-Xin Wen; Chun-Lin Zong; Chao Xu; Xiang-Yu Ma; Fa-Qi Wang; Ya-Fei Feng; Ya-Bo Yan; Wei Lei
Journal:  Int J Clin Exp Med       Date:  2015-10-15

10.  In vivo micro-CT scanning of a rabbit distal femur: repeatability and reproducibility.

Authors:  Michael J Voor; Shuo Yang; Robert L Burden; Seid W Waddell
Journal:  J Biomech       Date:  2007-08-22       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.