Literature DB >> 20803006

Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation.

Matthew T Novak1, Fan Yuan, William M Reichert.   

Abstract

Little is known mechanistically about why implanted glucose sensors lag behind blood glucose levels in both the time to peak sensor response and the magnitude of peak sensor response. A mathematical model of glucose transport from capillaries through surrounding tissue to the sensor surface was constructed to address how different aspects of the tissue affect glucose transport to an implanted sensor. Physiologically relevant values of capsule diffusion coefficient, capsule porosity, cellular glucose consumption, capsule thickness, and subcutaneous vessel density were used as inputs to create simulated sensor traces that mimic experimental instances of time lag and concentration attenuation relative to a given blood glucose profile. Using logarithmic sensitivity analysis, each parameter was analyzed to study the effect of these variables on both lag and attenuation. Results identify capsule thickness as the strongest determinant of sensor time lag, while subcutaneous vessel density and capsule porosity had the largest effects on attenuation of glucose that reaches the sensor surface. These findings provide mechanistic insight for the rational design of sensor modifications that may alleviate the deleterious consequences of tissue effects on implanted sensor performance.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20803006      PMCID: PMC2966551          DOI: 10.1007/s00216-010-4097-6

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  26 in total

Review 1.  Characterization of implantable biosensor membrane biofouling.

Authors:  N Wisniewski; F Moussy; W M Reichert
Journal:  Fresenius J Anal Chem       Date:  2000 Mar-Apr

2.  Histologic evaluation of the inflammatory response around implanted hollow fiber membranes.

Authors:  H Clark; T A Barbari; K Stump; G Rao
Journal:  J Biomed Mater Res       Date:  2000-10

3.  Treatment issues in type 1 diabetes.

Authors:  Zachary T Bloomgarden
Journal:  Diabetes Care       Date:  2002-01       Impact factor: 19.112

4.  Understanding spontaneous output fluctuations of an amperometric glucose sensor: effect of inhalation anesthesia and use of a nonenzyme containing electrode.

Authors:  W K Ward; M D Wood; J E Troupe
Journal:  ASAIO J       Date:  2000 Sep-Oct       Impact factor: 2.872

Review 5.  Implantable chemical sensors for real-time clinical monitoring: progress and challenges.

Authors:  Megan C Frost; Mark E Meyerhoff
Journal:  Curr Opin Chem Biol       Date:  2002-10       Impact factor: 8.822

6.  Application of chronic intravascular blood glucose sensor in dogs.

Authors:  J C Armour; J Y Lucisano; B D McKean; D A Gough
Journal:  Diabetes       Date:  1990-12       Impact factor: 9.461

7.  Quantification of information transfer via cellular signal transduction pathways.

Authors:  B N Kholodenko; J B Hoek; H V Westerhoff; G C Brown
Journal:  FEBS Lett       Date:  1997-09-08       Impact factor: 4.124

8.  Insulin-stimulated glucose transport in human adipocytes.

Authors:  T P Ciaraldi; O G Kolterman; J A Siegel; J M Olefsky
Journal:  Am J Physiol       Date:  1979-06

9.  Enzymatic glucose sensors. Improved long-term performance in vitro and in vivo.

Authors:  S J Updike; M C Shults; R K Rhodes; B J Gilligan; J O Luebow; D von Heimburg
Journal:  ASAIO J       Date:  1994 Apr-Jun       Impact factor: 2.872

10.  Morphologic and hemodynamic comparison of tumor and healing normal tissue microvasculature.

Authors:  M W Dewhirst; C Y Tso; R Oliver; C S Gustafson; T W Secomb; J F Gross
Journal:  Int J Radiat Oncol Biol Phys       Date:  1989-07       Impact factor: 7.038

View more
  30 in total

1.  Inflammasome components Asc and caspase-1 mediate biomaterial-induced inflammation and foreign body response.

Authors:  Ahsan F Malik; Rafaz Hoque; Xinshou Ouyang; Ayaz Ghani; Enping Hong; Khadija Khan; Laura Beth Moore; Gilbert Ng; Fay Munro; Richard A Flavell; Yan Shi; Themis R Kyriakides; Wajahat Z Mehal
Journal:  Proc Natl Acad Sci U S A       Date:  2011-11-22       Impact factor: 11.205

2.  The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants.

Authors:  Scott P Nichols; Ahyeon Koh; Nga L Brown; Michael B Rose; Bin Sun; Danielle L Slomberg; Daniel A Riccio; Bruce Klitzman; Mark H Schoenfisch
Journal:  Biomaterials       Date:  2012-06-27       Impact factor: 12.479

3.  Characterization of porous, dexamethasone-releasing polyurethane coatings for glucose sensors.

Authors:  Suzana G Vallejo-Heligon; Bruce Klitzman; William M Reichert
Journal:  Acta Biomater       Date:  2014-07-25       Impact factor: 8.947

Review 4.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

Review 5.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and foreign body response-part II: examples and application.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

6.  Preclinical Performance Evaluation of Percutaneous Glucose Biosensors: Experimental Considerations and Recommendations.

Authors:  Robert J Soto; Mark H Schoenfisch
Journal:  J Diabetes Sci Technol       Date:  2015-06-17

Review 7.  In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility.

Authors:  Robert J Soto; Jackson R Hall; Micah D Brown; James B Taylor; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2016-11-21       Impact factor: 6.986

Review 8.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

9.  Redundancy in Glucose Sensing: Enhanced Accuracy and Reliability of an Electrochemical Redundant Sensor for Continuous Glucose Monitoring.

Authors:  Amin Sharifi; Andrea Varsavsky; Johanna Ulloa; Jodie C Horsburgh; Sybil A McAuley; Balasubramanian Krishnamurthy; Alicia J Jenkins; Peter G Colman; Glenn M Ward; Richard J MacIsaac; Rajiv Shah; David N O'Neal
Journal:  J Diabetes Sci Technol       Date:  2016-05-03

Review 10.  Controlled release of biologics for the treatment of type 2 diabetes.

Authors:  Caslin A Gilroy; Kelli M Luginbuhl; Ashutosh Chilkoti
Journal:  J Control Release       Date:  2015-12-02       Impact factor: 9.776

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.