CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance.

Ga Ram Kim1, Jin Hur, Sang Min Lee, Hye-Jeong Lee, Yoo Jin Hong, Ji Eun Nam, Hua Sun Kim, Young Jin Kim, Byoung Wook Choi, Tae Hoon Kim, Kyu Ok Choe.   

Abstract

OBJECTIVE: We evaluated radiation doses, complication rates, and diagnostic accuracy for CT-guided percutaneous needle aspiration biopsy (NAB) procedures of pulmonary lesions performed with or without fluoroscopic guidance.
METHODS: A total of 142 patients were prospectively enrolled to receive CT-guided NAB with (Group I, n = 72) or without (Group II, n = 70) fluoroscopic guidance. Outcome measurements were patient and doctor radiation dose, and complication rate. Sensitivity, specificity and accuracy were calculated based on 123 NAB results.
RESULTS: The mean estimated effective patient radiation dose was 6.53 mSv in Group I and 2.72 mSv in Group II (p < 0.001). The mean estimated effective doctor dose was 0.054 mSv in Group I and 0.029 mSv in Group II (p < 0.001). The complication rate was significantly different between the two groups (13.4% versus 31.4%, p = 0.012). Sensitivity, specificity and accuracy for diagnosing pulmonary lesions were 97.8%, 100% and 98.4% in group I and 95.3%, 100% and 89.5% in group II (p > 0.05).
CONCLUSIONS: CT fluoroscopy-guided NAB of pulmonary lesions provides high diagnostic accuracy and can be performed with significantly fewer complications. However, radiation exposure to both patient and doctor were significantly higher than conventional CT-guided NAB.

Entities:  

Mesh:

Year:  2010        PMID: 20730613     DOI: 10.1007/s00330-010-1936-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  28 in total

1.  Pneumothorax post CT-guided lung biopsy: a comparison between detection on chest radiographs and CT.

Authors:  H K Bungay; J Berger; Z C Traill; F V Gleeson
Journal:  Br J Radiol       Date:  1999-12       Impact factor: 3.039

2.  Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules.

Authors:  T Hirose; K Mori; S Machida; K Tominaga; K Yokoi; M Adachi
Journal:  Jpn J Clin Oncol       Date:  2000-06       Impact factor: 3.019

3.  CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists.

Authors:  E K Paulson; D H Sheafor; D S Enterline; H P McAdams; T T Yoshizumi
Journal:  Radiology       Date:  2001-07       Impact factor: 11.105

4.  Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules?

Authors:  Takuji Yamagami; Shigeharu Iida; Takeharu Kato; Osamu Tanaka; Tsunehiko Nishimura
Journal:  AJR Am J Roentgenol       Date:  2003-03       Impact factor: 3.959

5.  Precise biopsy localization by computer tomography.

Authors:  J R Haaga; R J Alfidi
Journal:  Radiology       Date:  1976-03       Impact factor: 11.105

6.  Real-time CT-fluoroscopy for guidance of percutaneous drainage procedures.

Authors:  J J Froelich; B Saar; M Hoppe; N Ishaque; E M Walthers; J Regn; K J Klose
Journal:  J Vasc Interv Radiol       Date:  1998 Sep-Oct       Impact factor: 3.464

7.  Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?

Authors:  J P Ko; J O Shepard; E A Drucker; S L Aquino; A Sharma; B Sabloff; E Halpern; T C McLoud
Journal:  Radiology       Date:  2001-02       Impact factor: 11.105

8.  CT-guided fine-needle aspirations for diagnosis of benign and malignant disease.

Authors:  L P Harter; A A Moss; H I Goldberg; B H Gross
Journal:  AJR Am J Roentgenol       Date:  1983-02       Impact factor: 3.959

9.  Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures.

Authors:  Kee-Min Yeow; Pei-Kwei Tsay; Yun-Chung Cheung; Kar-Wai Lui; Kuang-Tse Pan; Andy Shau-Bin Chou
Journal:  J Vasc Interv Radiol       Date:  2003-05       Impact factor: 3.464

10.  Real-time CT fluoroscopy: usefulness in thoracic drainage.

Authors:  C A Meyer; C S White; J Wu; S F Futterer; P A Templeton
Journal:  AJR Am J Roentgenol       Date:  1998-10       Impact factor: 3.959

View more
  50 in total

1.  CT fluoroscopy-guided renal tumour cutting needle biopsy: retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure.

Authors:  Toshihiro Iguchi; Takao Hiraki; Yusuke Matsui; Hiroyasu Fujiwara; Jun Sakurai; Yoshihisa Masaoka; Hideo Gobara; Susumu Kanazawa
Journal:  Eur Radiol       Date:  2017-08-02       Impact factor: 5.315

2.  Is the rapid needle-out patient-rollover approach after CT-guided lung biopsy really effective for pneumothorax prevention?

Authors:  Zafar Neyaz; Namita Mohindra
Journal:  J Thorac Dis       Date:  2015-09       Impact factor: 2.895

3.  Computer tomography guided lung biopsy using interactive breath-hold control: a randomized study.

Authors:  Haseem Ashraf; Shella Krag-Andersen; Matiullah Naqibullah; Valentina Minddal; Annette Nørgaard; Therese Maria Henriette Naur; Peter Sand Myschetzky; Paul Frost Clementsen
Journal:  Ann Transl Med       Date:  2017-06

4.  Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules.

Authors:  Nicola Rotolo; Chiara Floridi; Andrea Imperatori; Federico Fontana; Anna Maria Ierardi; Monica Mangini; Veronica Arlant; Giuseppe De Marchi; Raffaele Novario; Lorenzo Dominioni; Carlo Fugazzola; Gianpaolo Carrafiello
Journal:  Eur Radiol       Date:  2015-06-06       Impact factor: 5.315

5.  Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique.

Authors:  Michele Anzidei; Renato Argirò; Andrea Porfiri; Fabrizio Boni; Marco Anile; Fulvio Zaccagna; Domenico Vitolo; Luca Saba; Alessandro Napoli; Andrea Leonardi; Flavia Longo; Federico Venuta; Mario Bezzi; Carlo Catalano
Journal:  Eur Radiol       Date:  2014-11-23       Impact factor: 5.315

6.  Effect of Body Habitus on Radiation Dose During CT Fluoroscopy-Guided Spine Injections.

Authors:  Ronald J Viola; Giao B Nguyen; Terry T Yoshizumi; Sandra S Stinnett; Jenny K Hoang; Peter G Kranz
Journal:  Interv Neuroradiol       Date:  2014-10-17       Impact factor: 1.610

7.  Radiation dose and image quality of CT fluoroscopy with partial exposure mode.

Authors:  Keisuke Takiguchi; Atsushi Urikura; Tsukasa Yoshida; Yoshihiro Nakaya; Masahiro Endo; Takeshi Aramaki
Journal:  Diagn Interv Radiol       Date:  2020-07       Impact factor: 2.630

8.  Percutaneous transthoracic needle biopsy of small (≤ 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance.

Authors:  Ji Yung Choo; Chang Min Park; Nyoung Keun Lee; Sang Min Lee; Hyun-Ju Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2012-09-14       Impact factor: 5.315

9.  Percutaneous lung biopsy: comparison between an augmented reality CT navigation system and standard CT-guided technique.

Authors:  R F Grasso; E Faiella; G Luppi; E Schena; F Giurazza; R Del Vescovo; F D'Agostino; R L Cazzato; B Beomonte Zobel
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-02-03       Impact factor: 2.924

Review 10.  Percutaneous lung biopsy: technique, efficacy, and complications.

Authors:  Ronald S Winokur; Bradley B Pua; Brian W Sullivan; David C Madoff
Journal:  Semin Intervent Radiol       Date:  2013-06       Impact factor: 1.513

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.