Literature DB >> 9763004

Real-time CT fluoroscopy: usefulness in thoracic drainage.

C A Meyer1, C S White, J Wu, S F Futterer, P A Templeton.   

Abstract

OBJECTIVE: The purpose of our study was to review the application of real-time CT fluoroscopy in the drainage of localized pleural and mediastinal collections. SUBJECTS AND METHODS: Between July 1996 and August 1997, 20 patients with 10 loculated pleural effusions, two mediastinal fluid collections, and 12 focal pneumothoraces were treated using CT fluoroscopy. The patient population was 25-77 years old and included 14 men and six women. Methods of drainage included using a modified Seldinger technique with a guidewire and serial dilators in 10 patients and a single-stick trocar technique in the remaining 14. Total room time, procedure time, and CT fluoroscopy time were recorded.
RESULTS: All 24 collections were successfully evacuated using either real-time or interrupted real-time CT fluoroscopy. The real-time capability of CT fluoroscopy proved particularly useful for rapid placement of drainage tubes in patients who were unable to cooperate with breathing instructions and in patients who had a narrow window of access. Average total room time was 65 min. Average procedure time was 32 min, and average CT fluoroscopy time was 143 sec.
CONCLUSION: CT fluoroscopy permits rapid drainage of intrathoracic collections. CT fluoroscopy is a particularly useful treatment for patients who are unable to perform breath-holding or in whom access to the drainage site is difficult.

Entities:  

Mesh:

Year:  1998        PMID: 9763004     DOI: 10.2214/ajr.171.4.9763004

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  9 in total

1.  CT-guided intervention using a patient laser marker system.

Authors:  R Kloeppel; T Weisse; F Deckert; W Wilke; S Pecher
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

2.  [CT fluoroscopy].

Authors:  P Rogalla; R Juran
Journal:  Radiologe       Date:  2004-07       Impact factor: 0.635

3.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

4.  Selective lumbar nerve root blocks with CT fluoroscopic guidance: technique, results, procedure time, and radiation dose.

Authors:  Andrew L Wagner
Journal:  AJNR Am J Neuroradiol       Date:  2004-10       Impact factor: 3.825

5.  Comparison of fully automated and semi-automated biopsy needles for lung biopsy under CT fluoroscopic guidance.

Authors:  R Yoshimatsu; T Yamagami; O Tanaka; H Miura; T Tanaka; T Suzuki; T Nishimura
Journal:  Br J Radiol       Date:  2011-08-09       Impact factor: 3.039

6.  Real-time CT fluoroscopy (CTF)-guided vertebroplasty in osteoporotic spine fractures.

Authors:  Ji Hyung Kim; Kyung Suk Park; Seung Yi; Hyun Chul Shin; Do Heum Yoon; Keung Nyun Kim
Journal:  Yonsei Med J       Date:  2005-10-31       Impact factor: 2.759

7.  Evaluation of surface dose and image quality using the half-scan mode in chest computed tomography-guided interventional radiology: a phantom study.

Authors:  Hiroaki Hasegawa; Jiro Sato; Ikuo Kobayashi
Journal:  Radiol Phys Technol       Date:  2018-02-27

8.  CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance.

Authors:  Ga Ram Kim; Jin Hur; Sang Min Lee; Hye-Jeong Lee; Yoo Jin Hong; Ji Eun Nam; Hua Sun Kim; Young Jin Kim; Byoung Wook Choi; Tae Hoon Kim; Kyu Ok Choe
Journal:  Eur Radiol       Date:  2010-08-22       Impact factor: 5.315

9.  Comparison between Image-Guided Transbronchial Cryobiopsies and Thoracoscopic Lung Biopsies in Canine Cadaver: A Pilot Study.

Authors:  Ilaria Falerno; Roberto Tamburro; Francesco Collivignarelli; Leonardo Della Salda; Luigi Navas; Rossella Terragni; Paolo Emidio Crisi; Andrea Paolini; Francesco Simeoni; Massimo Vignoli
Journal:  Animals (Basel)       Date:  2022-05-28       Impact factor: 3.231

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.