Literature DB >> 26543629

Is the rapid needle-out patient-rollover approach after CT-guided lung biopsy really effective for pneumothorax prevention?

Zafar Neyaz1, Namita Mohindra1.   

Abstract

Entities:  

Year:  2015        PMID: 26543629      PMCID: PMC4598504          DOI: 10.3978/j.issn.2072-1439.2015.09.34

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


× No keyword cloud information.
  20 in total

1.  Management of pneumothorax after percutaneous CT-guided lung biopsy.

Authors:  Takuji Yamagami; Toshiyuki Nakamura; Shigeharu Iida; Takeharu Kato; Tsunehiko Nishimura
Journal:  Chest       Date:  2002-04       Impact factor: 9.410

2.  What constitutes effective management of pneumothorax after CT-guided needle biopsy of the lung?

Authors:  Linda B Haramati; Galit Aviram
Journal:  Chest       Date:  2002-04       Impact factor: 9.410

3.  CT-guided transthoracic needle biopsy using a puncture site-down positioning technique.

Authors:  Fumiko Kinoshita; Takashi Kato; Kimihiko Sugiura; Masamichi Nishimura; Toshibumi Kinoshita; Masayuki Hashimoto; Toshio Kaminoh; Toshihide Ogawa
Journal:  AJR Am J Roentgenol       Date:  2006-10       Impact factor: 3.959

4.  Preventing pneumothorax after lung biopsy: the roll-over technique.

Authors:  D M Cassel; F A Birnberg
Journal:  Radiology       Date:  1990-01       Impact factor: 11.105

Review 5.  Technical aspects of needle aspiration lung biopsy: a personal perspective.

Authors:  E H Moore
Journal:  Radiology       Date:  1998-08       Impact factor: 11.105

6.  Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients.

Authors:  Jung Im Kim; Chang Min Park; Sang Min Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2015-02-01       Impact factor: 5.315

7.  Risks of Transthoracic Needle Biopsy: How High?

Authors:  Renda Soylemez Wiener; Daniel C Wiener; Michael K Gould
Journal:  Clin Pulm Med       Date:  2013-01-01

8.  Ipsilateral opposite-side aspiration in resistant pneumothorax after CT image guided lung biopsy: complementary role after simple needle aspiration.

Authors:  Daniel Yaffe; David Shitrit; Maya Gottfried; Gabriel Bartal; Jacob Sosna
Journal:  Chest       Date:  2013-09       Impact factor: 9.410

9.  Patient positioning after fine needle lung biopsy-effect on pneumothorax rate.

Authors:  K Tanisaro
Journal:  Acta Radiol       Date:  2003-01       Impact factor: 1.990

10.  Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy.

Authors:  Y Li; Y Du; T Y Luo; H F Yang; J H Yu; X X Xu; H J Zheng; B Li
Journal:  Clin Radiol       Date:  2015-07-11       Impact factor: 2.350

View more
  2 in total

1.  Lobar location of lesions in computed tomography-guided lung biopsy is correlated with major pneumothorax: A STROBE-compliant retrospective study with 1452 cases.

Authors:  Weipeng Yan; Xiaofang Guo; Jing Zhang; Junfen Zhou; Changchun Chen; Manxiang Wang; Zhaoxi Zhang; Yulin Liu
Journal:  Medicine (Baltimore)       Date:  2019-07       Impact factor: 1.817

2.  Effect of puncture sites on pneumothorax after lung CT-guided biopsy.

Authors:  Li-Chuan Zeng; Hua-Qiang Liao; Wen-Bin Wu; Yu-Dong Zhang; Feng-Chun Ren; Qu Wang; Ming-Guo Xie
Journal:  Medicine (Baltimore)       Date:  2020-04       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.