PURPOSE: Percutaneous lung biopsies (PLBs) performed for the evaluation of pulmonary masses require image guidance to avoid critical structures. A new CT navigation system (SIRIO, "Sistema robotizzato assistito per il puntamento intraoperatorio") for PLBs was validated. METHODS: The local Institutional Review Board approved this retrospective study. Image-guided PLBs in 197 patients were performed with a CT navigation system (SIRIO). The procedures were reviewed based on the number of CT scans, patients' radiation exposure and procedural time recorded. Comparison was performed with a group of 72 patients undergoing standard CT-guided PLBs. Sensitivity, specificity and overall diagnostic accuracy were assessed in both groups. RESULTS: SIRIO-guided PLBs showed a significant reduction in procedure time, number of required CT scans and the radiation dose administered to patients ([Formula: see text]). In terms of diagnostic accuracy, SIRIO proved to be more accurate for small-sized lesions ([Formula: see text]20 mm) than standard CT-guidance. CONCLUSION: SIRIO proved to be a reliable and effective tool when performing CT-guided PLBs and was especially useful for sampling small ([Formula: see text]20 mm) lesions.
PURPOSE: Percutaneous lung biopsies (PLBs) performed for the evaluation of pulmonary masses require image guidance to avoid critical structures. A new CT navigation system (SIRIO, "Sistema robotizzato assistito per il puntamento intraoperatorio") for PLBs was validated. METHODS: The local Institutional Review Board approved this retrospective study. Image-guided PLBs in 197 patients were performed with a CT navigation system (SIRIO). The procedures were reviewed based on the number of CT scans, patients' radiation exposure and procedural time recorded. Comparison was performed with a group of 72 patients undergoing standard CT-guided PLBs. Sensitivity, specificity and overall diagnostic accuracy were assessed in both groups. RESULTS: SIRIO-guided PLBs showed a significant reduction in procedure time, number of required CT scans and the radiation dose administered to patients ([Formula: see text]). In terms of diagnostic accuracy, SIRIO proved to be more accurate for small-sized lesions ([Formula: see text]20 mm) than standard CT-guidance. CONCLUSION: SIRIO proved to be a reliable and effective tool when performing CT-guided PLBs and was especially useful for sampling small ([Formula: see text]20 mm) lesions.
Authors: Kwang Nam Jin; Chang Min Park; Jin Mo Goo; Hyun Ju Lee; Youkyung Lee; Jung Im Kim; So Young Choi; Hyo-Cheol Kim Journal: Eur Radiol Date: 2010-09 Impact factor: 5.315
Authors: Luca Maria Sconfienza; Giovanni Mauri; Francesco Grossi; Mauro Truini; Giovanni Serafini; Francesco Sardanelli; Carmelina Murolo Journal: Radiology Date: 2012-11-30 Impact factor: 11.105
Authors: Rui Li; Sheng Xu; William F Pritchard; John W Karanian; Venkatesh P Krishnasamy; Bradford J Wood; Zion Tsz Ho Tse Journal: Ann Biomed Eng Date: 2018-01-05 Impact factor: 3.934
Authors: Jacob T Gibby; Samuel A Swenson; Steve Cvetko; Raj Rao; Ramin Javan Journal: Int J Comput Assist Radiol Surg Date: 2018-06-22 Impact factor: 2.924
Authors: Rachel Hecht; Ming Li; Quirina M B de Ruiter; William F Pritchard; Xiaobai Li; Venkatesh Krishnasamy; Wael Saad; John W Karanian; Bradford J Wood Journal: Cardiovasc Intervent Radiol Date: 2020-01-08 Impact factor: 2.740
Authors: R C Rouchy; A Moreau-Gaudry; E Chipon; S Aubry; L Pazart; B Lapuyade; M Durand; M Hajjam; S Pottier; B Renard; R Logier; X Orry; A Cherifi; E Quehen; G Kervio; O Favelle; F Patat; E De Kerviler; C Hughes; M Medici; J Ghelfi; A Mounier; I Bricault Journal: Trials Date: 2017-07-06 Impact factor: 2.279