Literature DB >> 19353342

Cone-beam computed tomography: a new method for imaging of the temporal bone.

L I Peltonen1, A A Aarnisalo, Y Käser, M K Kortesniemi, S Robinson, A Suomalainen, J Jero.   

Abstract

BACKGROUND: Clinical cone-beam computed tomography (CBCT), used in diagnostics of dental and maxillofacial radiology for almost 10 years, allows three-dimensional (3D) imaging of a focused area, with reasonable radiation dose.
PURPOSE: To clarify the applicability of CBCT in imaging of the temporal bone.
MATERIAL AND METHODS: We imaged cadaver temporal bones, one non-operated and five postmortem operated, with CBCT to evaluate the accuracy of this method in showing clinically important landmarks and the positions of middle-ear implants. In addition, to clarify the imaging protocols for the best possible result, we conducted a contrast-to-noise ratio (CNR) analysis by imaging a specially built phantom insert with different protocols.
RESULTS: For all the temporal bones, image quality was good and of diagnostic value, and the surgical landmarks as well as positions and details of the implants could be accurately observed. Based on measurements conducted with the phantom, the best possible clarity of the images with the machine used (3D Accuitomo; Morita Co., Kyoto, Japan) was achieved with a tube voltage of 80 kVp and a current of 4 mA.
CONCLUSION: Cone-beam CT is a promising new method for otologic imaging, based on its accuracy and relatively low radiation exposure per investigation.

Mesh:

Year:  2009        PMID: 19353342     DOI: 10.1080/02841850902839700

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  9 in total

1.  Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study.

Authors:  Afshin Teymoortash; Stella Hamzei; Tobias Murthum; Behfar Eivazi; Ingo Kureck; Jochen A Werner
Journal:  Surg Radiol Anat       Date:  2010-08-13       Impact factor: 1.246

2.  Morphological concordance between CBCT and MDCT: a paranasal sinus-imaging anatomical study.

Authors:  J Demeslay; S Vergez; E Serrano; P Chaynes; P Cantet; B Chaput; G de Bonnecaze
Journal:  Surg Radiol Anat       Date:  2015-08-04       Impact factor: 1.246

3.  Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT).

Authors:  C Güldner; S Wiegand; R Weiss; S Bien; A Sesterhenn; A Teymoortash; I Diogo
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-07-30       Impact factor: 2.503

4.  Imaging re-evaluation of the tympanic segment of the facial nerve canal using cone-beam computed tomography compared with multi-slice computed tomography.

Authors:  Zhengyu Zhang; Hongxia Yin; Zheng Wang; Jing Li; Han Lv; Pengfei Zhao; Zhenghan Yang; Zhenchang Wang
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-05-02       Impact factor: 2.503

5.  Visualization of anatomy in normal and pathologic middle ears by cone beam CT.

Authors:  Christian Güldner; Isabell Diogo; Eva Bernd; Stephanie Dräger; Magis Mandapathil; Afshin Teymoortash; Hesham Negm; Thomas Wilhelm
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-10-17       Impact factor: 2.503

Review 6.  Diagnostic imaging modalities in head and neck disease.

Authors:  Florian Dammann; Friedrich Bootz; Mathias Cohnen; Stefan Hassfeld; Marcos Tatagiba; Sabrina Kösling
Journal:  Dtsch Arztebl Int       Date:  2014-06-09       Impact factor: 5.594

7.  Sinus tympani revisited for planning retrofacial approach-radiologic study in pneumatized temporal bones and its surgical implications.

Authors:  Tomasz Wojciechowski; Robert Bartoszewicz; Kazimierz Szopiński
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-08-05       Impact factor: 3.236

8.  A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose.

Authors:  R Pauwels; O Silkosessak; R Jacobs; R Bogaerts; H Bosmans; S Panmekiate
Journal:  Dentomaxillofac Radiol       Date:  2014-04-08       Impact factor: 2.419

9.  Intratympanic application of triamcinolone in sudden hearing loss-radiologic anatomy in cone beam CT and its' correlation to clinical outcome.

Authors:  Willi Roßberg; Friedrich Goetz; Max Eike Timm; Thomas Lenarz; Victor Helmstaedter
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-03-23       Impact factor: 2.503

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.