Literature DB >> 16876067

Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study.

Miet Loubele1, Frederik Maes, Filip Schutyser, Guy Marchal, Reinhilde Jacobs, Paul Suetens.   

Abstract

OBJECTIVES: The objective of this study was to quantitatively assess the quality of jawbone models generated from cone beam computed tomography (CBCT) by comparison with similar models obtained from multislice spiral computed tomography (MSCT).
MATERIAL AND METHODS: Three case studies were performed involving images of anthropomorphic head phantoms and real patients acquired with 3 CBCT (NewTom 9000 DVT, Accuitomo 3D, and i-CAT) and 2 MSCT scanners (Somatom VolumeZoom and Lightspeed). Bone was segmented from the CBCT and MSCT images using global thresholding. CBCT vs MSCT segmentation differences were assessed by comparing bone thickness measurements at anatomically corresponding sites, identified automatically by CBCT to MSCT image registration.
RESULTS: There was a statistically significant difference between the MSCT and CBCT segmented bone thicknesses, varying from 0.05 +/- 0.47 mm (i-CAT) up to 1.2 +/- 1.00 mm (3D Accuitomo, posterior maxilla).
CONCLUSIONS: An automated, reproducible, and observer-independent method has been developed to assess the quality of CBCT bone models using MSCT as a clinically established method of reference. Our validation method is generally applicable in cases where no geometric ground-truth is available.

Entities:  

Mesh:

Year:  2006        PMID: 16876067     DOI: 10.1016/j.tripleo.2005.10.039

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  45 in total

1.  The influence of exposure parameters on jawbone model accuracy using cone beam CT and multislice CT.

Authors:  B Vandenberghe; S Luchsinger; J Hostens; E Dhoore; R Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

2.  Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study.

Authors:  Afshin Teymoortash; Stella Hamzei; Tobias Murthum; Behfar Eivazi; Ingo Kureck; Jochen A Werner
Journal:  Surg Radiol Anat       Date:  2010-08-13       Impact factor: 1.246

Review 3.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

4.  Evaluation of demineralized bone and bone transplants in vitro and in vivo with cone beam computed tomography imaging.

Authors:  F G Draenert; F Gebhart; M Berthold; M Gosau; W Wagner
Journal:  Dentomaxillofac Radiol       Date:  2010-07       Impact factor: 2.419

5.  Cone-beam computed tomography in assessment of periodontal ligament space: in vitro study on artificial tooth model.

Authors:  Nurdan Ozmeric; Irina Kostioutchenko; Georg Hägler; Matthias Frentzen; Pia-Merete Jervøe-Storm
Journal:  Clin Oral Investig       Date:  2008-02-05       Impact factor: 3.573

6.  Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: a tale of two CTs.

Authors:  R Patcas; G Markic; L Müller; O Ullrich; T Peltomäki; C J Kellenberger; C A Karlo
Journal:  Dentomaxillofac Radiol       Date:  2012-05-03       Impact factor: 2.419

7.  Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom.

Authors:  J Bamba; K Araki; A Endo; T Okano
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

8.  The effect of scan parameters on cone beam CT trabecular bone microstructural measurements of the human mandible.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; I H A Aartman; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013-10-16       Impact factor: 2.419

9.  Automated implant segmentation in cone-beam CT using edge detection and particle counting.

Authors:  Ruben Pauwels; Reinhilde Jacobs; Hilde Bosmans; Pisha Pittayapat; Pasupen Kosalagood; Onanong Silkosessak; Soontra Panmekiate
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07       Impact factor: 2.924

10.  Quantitative percussion diagnostics and bone density analysis of the implant-bone interface in a pre- and postmortem human subject.

Authors:  Cherilyn G Sheets; Dee Dee Hui; Vaibhav Bajaj; James C Earthman
Journal:  Int J Oral Maxillofac Implants       Date:  2013 Nov-Dec       Impact factor: 2.804

View more