Literature DB >> 20681803

Computational electromagnetic analysis in a human head model with EEG electrodes and leads exposed to RF-field sources at 915 MHz and 1748 MHz.

Leonardo M Angelone1, Giorgi Bit-Babik, Chung-Kwang Chou.   

Abstract

An electromagnetic analysis of a human head with EEG electrodes and leads exposed to RF-field sources was performed by means of Finite-Difference Time-Domain simulations on a 1-mm(3) MRI-based human head model. RF-field source models included a half-wave dipole, a patch antenna, and a realistic CAD-based mobile phone at 915 MHz and 1748 MHz. EEG electrodes/leads models included two configurations of EEG leads, both a standard 10-20 montage with 19 electrodes and a 32-electrode cap, and metallic and high resistive leads. Whole-head and peak 10-g average SAR showed less than 20% changes with and without leads. Peak 1-g and 10-g average SARs were below the ICNIRP and IEEE guideline limits. Conversely, a comprehensive volumetric assessment of changes in the RF field with and without metallic EEG leads showed an increase of two orders of magnitude in single-voxel power absorption in the epidermis and a 40-fold increase in the brain during exposure to the 915 MHz mobile phone. Results varied with the geometry and conductivity of EEG electrodes/leads. This enhancement confirms the validity of the question whether any observed effects in studies involving EEG recordings during RF-field exposure are directly related to the RF fields generated by the source or indirectly to the RF-field-induced currents due to the presence of conductive EEG leads.

Entities:  

Mesh:

Year:  2010        PMID: 20681803      PMCID: PMC2917271          DOI: 10.1667/RR1933.1

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  27 in total

1.  Specific absorption rates and induced current densities for an anatomy-based model of the human for exposure to time-varying magnetic fields of MRI.

Authors:  O P Gandhi; X B Chen
Journal:  Magn Reson Med       Date:  1999-04       Impact factor: 4.668

2.  Dosimetric comparison of the specific anthropomorphic mannequin (SAM) to 14 anatomical head models using a novel definition for the mobile phone positioning.

Authors:  Wolfgang Kainz; Andreas Christ; Tocher Kellom; Seth Seidman; Neviana Nikoloski; Brian Beard; Niels Kuster
Journal:  Phys Med Biol       Date:  2005-07-06       Impact factor: 3.609

3.  Design and performance issues of RF coils utilized in ultra high field MRI: experimental and numerical evaluations.

Authors:  Tamer S Ibrahim; Alayar Kangarlu; Donald W Chakeress
Journal:  IEEE Trans Biomed Eng       Date:  2005-07       Impact factor: 4.538

4.  On the effect of resistive EEG electrodes and leads during 7 T MRI: simulation and temperature measurement studies.

Authors:  Leonardo M Angelone; Christos E Vasios; Graham Wiggins; Patrick L Purdon; Giorgio Bonmassar
Journal:  Magn Reson Imaging       Date:  2006-03-27       Impact factor: 2.546

Review 5.  MRI-induced heating of selected thin wire metallic implants-- laboratory and computational studies-- findings and new questions raised.

Authors:  H Bassen; W Kainz; G Mendoza; T Kellom
Journal:  Minim Invasive Ther Allied Technol       Date:  2006       Impact factor: 2.442

6.  In-depth study of the electromagnetics of ultrahigh-field MRI.

Authors:  Tamer S Ibrahim; Chad Mitchell; Roney Abraham; Petra Schmalbrock
Journal:  NMR Biomed       Date:  2007-02       Impact factor: 4.044

7.  EEG/(f)MRI measurements at 7 Tesla using a new EEG cap ("InkCap").

Authors:  Christos E Vasios; Leonardo M Angelone; Patrick L Purdon; Jyrki Ahveninen; John W Belliveau; Giorgio Bonmassar
Journal:  Neuroimage       Date:  2006-10-10       Impact factor: 6.556

8.  SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Specific energy absorption rate.

Authors:  C M Collins; S Li; M B Smith
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

9.  Simulation of exposure and SAR estimation for adult and child heads exposed to radiofrequency energy from portable communication devices.

Authors:  G Bit-Babik; A W Guy; C-K Chou; A Faraone; M Kanda; A Gessner; J Wang; O Fujiwara
Journal:  Radiat Res       Date:  2005-05       Impact factor: 2.841

Review 10.  Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz). International Commission on Non-Ionizing Radiation Protection.

Authors: 
Journal:  Health Phys       Date:  1998-04       Impact factor: 1.316

View more
  3 in total

1.  Effects of chronic exposure to radiofrequency electromagnetic fields on energy balance in developing rats.

Authors:  Amandine Pelletier; Stéphane Delanaud; Pauline Décima; Gyorgy Thuroczy; René de Seze; Matteo Cerri; Véronique Bach; Jean-Pierre Libert; Nathalie Loos
Journal:  Environ Sci Pollut Res Int       Date:  2012-11-10       Impact factor: 4.223

2.  Numerical simulation of the radiofrequency safety of 128-channel hd-EEG nets on a 29-month-old whole-body model in a 3 Tesla MRI.

Authors:  Hongbae Jeong; Georgios Ntolkeras; P Ellen Grant; Giorgio Bonmassar
Journal:  IEEE Trans Electromagn Compat       Date:  2021-08-16       Impact factor: 2.036

3.  A novel brain stimulation technology provides compatibility with MRI.

Authors:  Peter Serano; Leonardo M Angelone; Husam Katnani; Emad Eskandar; Giorgio Bonmassar
Journal:  Sci Rep       Date:  2015-04-29       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.