Literature DB >> 16824975

On the effect of resistive EEG electrodes and leads during 7 T MRI: simulation and temperature measurement studies.

Leonardo M Angelone1, Christos E Vasios, Graham Wiggins, Patrick L Purdon, Giorgio Bonmassar.   

Abstract

The purpose of the study was to assess the effects of electrodes and leads on electromagnetic field and specific absorption rate (SAR) distributions during simultaneous electroencephalography (EEG) and 7-T MRI. Two different approaches were evaluated and compared to the case without electrodes: (a) the use of different EEG lead resistivity and (b) the use of a radiofrequency (RF) resistor on the lead near the EEG electrode. These configurations are commonly used in research and clinical settings. Electromagnetic field and SAR distributions generated by the transmit RF coil were evaluated using finite difference time domain simulations on an anatomically accurate head model. The spatiotemporal changes of temperature were estimated with the heat equation. Temperature changes during turbo spin echo sequences were also measured using a custom-made phantom: the conductive head mannequin anthropomorphic (CHEMA). The results of this study showed that the SAR and temperature distributions in CHEMA (a) increased when using low resistive leads, with respect to the no-electrode case; (b) were affected by the resistivity of the EEG leads, with carbon fiber leads performing better than standard copper leads; and (c) were not affected by the use of an RF resistor between the EEG electrode and the lead.

Entities:  

Mesh:

Year:  2006        PMID: 16824975     DOI: 10.1016/j.mri.2006.01.006

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  20 in total

1.  Assessing the Electromagnetic Fields Generated By a Radiofrequency MRI Body Coil at 64 MHz: Defeaturing Versus Accuracy.

Authors:  Elena Lucano; Micaela Liberti; Gonzalo G Mendoza; Tom Lloyd; Maria Ida Iacono; Francesca Apollonio; Steve Wedan; Wolfgang Kainz; Leonardo M Angelone
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-17       Impact factor: 4.538

2.  Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI.

Authors:  Leonardo M Angelone; Jyrki Ahveninen; John W Belliveau; Giorgio Bonmassar
Journal:  IEEE Trans Med Imaging       Date:  2010-03-22       Impact factor: 10.048

3.  Reference-free removal of EEG-fMRI ballistocardiogram artifacts with harmonic regression.

Authors:  Pavitra Krishnaswamy; Giorgio Bonmassar; Catherine Poulsen; Eric T Pierce; Patrick L Purdon; Emery N Brown
Journal:  Neuroimage       Date:  2015-07-05       Impact factor: 6.556

4.  How to design and construct a 3D-printed human head phantom.

Authors:  Sossena Wood; Tiago Martins; Tamer S Ibrahim
Journal:  J 3D Print Med       Date:  2019-08-21

5.  Effects of transcranial direct current stimulation (tDCS) on human regional cerebral blood flow.

Authors:  Xin Zheng; David C Alsop; Gottfried Schlaug
Journal:  Neuroimage       Date:  2011-06-16       Impact factor: 6.556

6.  Feasibility of using linearly polarized rotating birdcage transmitters and close-fitting receive arrays in MRI to reduce SAR in the vicinity of deep brain simulation implants.

Authors:  Laleh Golestanirad; Boris Keil; Leonardo M Angelone; Giorgio Bonmassar; Azma Mareyam; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2016-04-05       Impact factor: 4.668

7.  Computational electromagnetic analysis in a human head model with EEG electrodes and leads exposed to RF-field sources at 915 MHz and 1748 MHz.

Authors:  Leonardo M Angelone; Giorgi Bit-Babik; Chung-Kwang Chou
Journal:  Radiat Res       Date:  2010-07       Impact factor: 2.841

8.  Polymer thick film technology for improved simultaneous dEEG/MRI recording: Safety and MRI data quality.

Authors:  Catherine Poulsen; Daniel G Wakeman; Seyed Reza Atefi; Phan Luu; Amy Konyn; Giorgio Bonmassar
Journal:  Magn Reson Med       Date:  2016-02-15       Impact factor: 4.668

9.  An anatomically realistic temperature phantom for radiofrequency heating measurements.

Authors:  Nadine N Graedel; Jonathan R Polimeni; Bastien Guerin; Borjan Gagoski; Giorgio Bonmassar; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-02-18       Impact factor: 4.668

10.  An open-source hardware and software system for acquisition and real-time processing of electrophysiology during high field MRI.

Authors:  Patrick L Purdon; Hernan Millan; Peter L Fuller; Giorgio Bonmassar
Journal:  J Neurosci Methods       Date:  2008-08-05       Impact factor: 2.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.