Literature DB >> 34675444

Numerical simulation of the radiofrequency safety of 128-channel hd-EEG nets on a 29-month-old whole-body model in a 3 Tesla MRI.

Hongbae Jeong1, Georgios Ntolkeras2, P Ellen Grant2, Giorgio Bonmassar1.   

Abstract

This study investigates the radiofrequency (RF) induced heating in a pediatric whole-body voxel model with a high-density electroencephalogram (hd-EEG) net during magnetic resonance imaging (MRI) at 3 Tesla. A total of three cases were studied: no net (NoNet), a resistive hd-EEG (NeoNet), and a copper (CuNet) net. The maximum values of specific absorption rate averaged over 10g-mass (10gSAR) in the head were calculated with the NeoNet was 12.51 W/kg and in the case of the NoNet was 12.40 W/kg. In contrast, the CuNet case was 17.04 W/Kg. Temperature simulations were conducted to determine the RF-induced heating without and with hd-EEG nets (NeoNet and CuNet) during an MRI scan using an age-corrected and thermoregulated perfusion for the child model. The results showed that the maximum temperature estimated in the child's head was 38.38 °C for the NoNet, 38.43 °C for the NeoNet, and 43.05 °C for the CuNet. In the case of NeoNet, the maximum temperature estimated in the child's head remained compliant with IEC 60601 for the MRI RF safety limit. However, the case of CuNet estimated to exceed the RF safety limit, which may require an appropriate cooling period or a hardware design to suppress the RF-induced heating.

Entities:  

Keywords:  Anatomical models; MARTIN; Pennes bio-heat equation; Sim4Life; finite-difference time-domain (FDTD); pediatric MRI; perfusion; specific absorption rate (SAR)

Year:  2021        PMID: 34675444      PMCID: PMC8522907          DOI: 10.1109/TEMC.2021.3097732

Source DB:  PubMed          Journal:  IEEE Trans Electromagn Compat        ISSN: 0018-9375            Impact factor:   2.036


  41 in total

1.  EEG-fMRI of epileptic spikes: concordance with EEG source localization and intracranial EEG.

Authors:  Christian-G Bénar; Christophe Grova; Eliane Kobayashi; Andrew P Bagshaw; Yahya Aghakhani; François Dubeau; Jean Gotman
Journal:  Neuroimage       Date:  2006-01-18       Impact factor: 6.556

2.  Measurement, simulation and uncertainty assessment of implant heating during MRI.

Authors:  E Neufeld; S Kühn; G Szekely; N Kuster
Journal:  Phys Med Biol       Date:  2009-06-12       Impact factor: 3.609

3.  ACR guidance document on MR safe practices: Updates and critical information 2019.

Authors:  Todd D Greenberg; Michael N Hoff; Tobias B Gilk; Edward F Jackson; Emanuel Kanal; Alexander M McKinney; Joseph G Och; Ivan Pedrosa; Tina L Rampulla; Scott B Reeder; Jeffrey M Rogg; Frank G Shellock; Robert E Watson; Jeffrey C Weinreb; Dina Hernandez
Journal:  J Magn Reson Imaging       Date:  2019-07-29       Impact factor: 4.813

Review 4.  Combining EEG and fMRI in the study of epileptic discharges.

Authors:  Jean Gotman; Francesca Pittau
Journal:  Epilepsia       Date:  2011-07       Impact factor: 5.864

5.  Interrelating sentinel event alert #38 with the ACR guidance document on MR safe practices: 2013. An MRI accreditation safety review tool.

Authors:  Tobias Gilk; Emanuel Kanal
Journal:  J Magn Reson Imaging       Date:  2013-01-23       Impact factor: 4.813

6.  Computational electromagnetic analysis in a human head model with EEG electrodes and leads exposed to RF-field sources at 915 MHz and 1748 MHz.

Authors:  Leonardo M Angelone; Giorgi Bit-Babik; Chung-Kwang Chou
Journal:  Radiat Res       Date:  2010-07       Impact factor: 2.841

7.  Dominant factors affecting temperature rise in simulations of human thermoregulation during RF exposure.

Authors:  Ilkka Laakso; Akimasa Hirata
Journal:  Phys Med Biol       Date:  2011-11-11       Impact factor: 3.609

8.  Age-Related Changes of Normal Cerebral and Cardiac Blood Flow in Children and Adults Aged 7 Months to 61 Years.

Authors:  Can Wu; Amir R Honarmand; Susanne Schnell; Ryan Kuhn; Samantha E Schoeneman; Sameer A Ansari; James Carr; Michael Markl; Ali Shaibani
Journal:  J Am Heart Assoc       Date:  2016-01-04       Impact factor: 5.501

9.  Interictal and ictal source localization for epilepsy surgery using high-density EEG with MEG: a prospective long-term study.

Authors:  Chris Plummer; Simon J Vogrin; William P Woods; Michael A Murphy; Mark J Cook; David T J Liley
Journal:  Brain       Date:  2019-04-01       Impact factor: 13.501

10.  Presurgical accuracy of dipole clustering in MRI-negative pediatric patients with epilepsy: Validation against intracranial EEG and resection.

Authors:  Georgios Ntolkeras; Eleonora Tamilia; Michel AlHilani; Jeffrey Bolton; P Ellen Grant; Sanjay P Prabhu; Joseph R Madsen; Steven M Stufflebeam; Phillip L Pearl; Christos Papadelis
Journal:  Clin Neurophysiol       Date:  2021-03-26       Impact factor: 4.861

View more
  1 in total

1.  Segmenting electroencephalography wires reduces radiofrequency shielding artifacts in simultaneous electroencephalography and functional magnetic resonance imaging at 7 T.

Authors:  Thanh Phong Lê; Rolf Gruetter; João Jorge; Özlem Ipek
Journal:  Magn Reson Med       Date:  2022-05-16       Impact factor: 3.737

  1 in total