Literature DB >> 20664867

Microdevices integrating affinity columns and capillary electrophoresis for multibiomarker analysis in human serum.

Weichun Yang1, Ming Yu, Xiuhua Sun, Adam T Woolley.   

Abstract

Biomarkers in human body fluids have great potential for use in screening for diseases such as cancer and diabetes, diagnosis, determining the effectiveness of treatments, and detecting recurrence. Present 96-well immunoassay technology effectively analyzes large numbers of samples; however, this approach is more expensive and less time effective on single or a few samples. In contrast, microfluidic systems are well suited for assaying small numbers of specimens in a point-of-care setting, provided suitable procedures are developed to work within peak capacity constraints when analyzing complex mixtures like human blood serum. Here, we developed integrated microdevices with an affinity column and capillary electrophoresis channels to isolate and quantitate a panel of proteins in complex matrices. To form an affinity column, a thin film of a reactive polymer was photopolymerized in a microchannel, and four antibodies were covalently immobilized to it. The retained protein amounts were consistent from chip to chip, demonstrating reproducibility. Furthermore, the signals from four fluorescently labeled proteins captured on-column were in the same range after rinsing, indicating the column has little bias toward any of the four antibodies or their antigens. These affinity columns have been integrated with capillary electrophoresis separation, enabling us to simultaneously quantify four protein biomarkers in human blood serum in the low ng mL(-1) range using either a calibration curve or standard addition. Our systems provide a fast, integrated and automated platform for multiple biomarker quantitation in complex media such as human blood serum.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20664867      PMCID: PMC2998056          DOI: 10.1039/c005288d

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  29 in total

1.  Antibody immobilization to high-performance liquid chromatography supports. Characterization of maximum loading capacity for intact immunoglobulin G and Fab fragments.

Authors:  W Clarke; J D Beckwith; A Jackson; B Reynolds; E M Karle; D S Hage
Journal:  J Chromatogr A       Date:  2000-08-04       Impact factor: 4.759

2.  Design and optimization of on-chip capillary electrophoresis.

Authors:  Rajiv Bharadwaj; Juan G Santiago; Bijan Mohammadi
Journal:  Electrophoresis       Date:  2002-08       Impact factor: 3.535

3.  Chip-based immunoaffinity CE: application to the measurement of brain-derived neurotrophic factor in skin biopsies.

Authors:  Terry M Phillips; Edward F Wellner
Journal:  Electrophoresis       Date:  2009-07       Impact factor: 3.535

4.  Integrated Multi-process Microfluidic Systems for Automating Analysis.

Authors:  Weichun Yang; Adam T Woolley
Journal:  JALA Charlottesv Va       Date:  2010-06-01

5.  Prognostic effect of perioperative change of serum carcinoembryonic antigen level: a useful tool for detection of systemic recurrence in rectal cancer.

Authors:  Yoon-Ah Park; Kang Young Lee; Nam Kyu Kim; Seung Hyuk Baik; Seung Kook Sohn; Chang Whan Cho
Journal:  Ann Surg Oncol       Date:  2006-03-13       Impact factor: 5.344

6.  Affinity monolith preconcentrators for polymer microchip capillary electrophoresis.

Authors:  Weichun Yang; Xiuhua Sun; Tao Pan; Adam T Woolley
Journal:  Electrophoresis       Date:  2008-08       Impact factor: 3.535

7.  Affinity monolith-integrated poly(methyl methacrylate) microchips for on-line protein extraction and capillary electrophoresis.

Authors:  Xiuhua Sun; Weichun Yang; Tao Pan; Adam T Woolley
Journal:  Anal Chem       Date:  2008-05-15       Impact factor: 6.986

8.  Multimarker circulating DNA assay for assessing blood of prostate cancer patients.

Authors:  Eiji Sunami; Masaru Shinozaki; Celestia S Higano; Robert Wollman; Tanya B Dorff; Steven J Tucker; Steve R Martinez; Ryuich Mizuno; Frederick R Singer; Dave S B Hoon
Journal:  Clin Chem       Date:  2009-01-08       Impact factor: 8.327

9.  Prevalence of prostate cancer among men with a prostate-specific antigen level < or =4.0 ng per milliliter.

Authors:  Ian M Thompson; Donna K Pauler; Phyllis J Goodman; Catherine M Tangen; M Scott Lucia; Howard L Parnes; Lori M Minasian; Leslie G Ford; Scott M Lippman; E David Crawford; John J Crowley; Charles A Coltman
Journal:  N Engl J Med       Date:  2004-05-27       Impact factor: 91.245

Review 10.  Novel approaches to identification of biomarkers for detection of early stage cancer.

Authors:  Nancy B Kiviat; Cathy W Critchlow
Journal:  Dis Markers       Date:  2002       Impact factor: 3.434

View more
  19 in total

1.  Single-monomer formulation of polymerized polyethylene glycol diacrylate as a nonadsorptive material for microfluidics.

Authors:  Chad I Rogers; Jayson V Pagaduan; Gregory P Nordin; Adam T Woolley
Journal:  Anal Chem       Date:  2011-07-20       Impact factor: 6.986

Review 2.  Advances in microfluidic materials, functions, integration, and applications.

Authors:  Pamela N Nge; Chad I Rogers; Adam T Woolley
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

3.  A multiplexed immunoaggregation biomarker assay using a two-stage micro resistive pulse sensor.

Authors:  Y Han; H Wu; F Liu; G Cheng; J Zhe
Journal:  Biomicrofluidics       Date:  2016-03-16       Impact factor: 2.800

4.  Microfluidic Valves Made From Polymerized Polyethylene Glycol Diacrylate.

Authors:  Chad I Rogers; Joseph B Oxborrow; Ryan R Anderson; Long-Fang Tsai; Gregory P Nordin; Adam T Woolley
Journal:  Sens Actuators B Chem       Date:  2014-02-01       Impact factor: 7.460

5.  Multilayer polymer microchip capillary array electrophoresis devices with integrated on-chip labeling for high-throughput protein analysis.

Authors:  Ming Yu; Qingsong Wang; James E Patterson; Adam T Woolley
Journal:  Anal Chem       Date:  2011-04-12       Impact factor: 6.986

6.  Integrated electrokinetically driven microfluidic devices with pH-mediated solid-phase extraction coupled to microchip electrophoresis for preterm birth biomarkers.

Authors:  Mukul Sonker; Radim Knob; Vishal Sahore; Adam T Woolley
Journal:  Electrophoresis       Date:  2017-04-25       Impact factor: 3.535

7.  Electrokinetically operated microfluidic devices for integrated immunoaffinity monolith extraction and electrophoretic separation of preterm birth biomarkers.

Authors:  Mukul Sonker; Ellen K Parker; Anna V Nielsen; Vishal Sahore; Adam T Woolley
Journal:  Analyst       Date:  2017-12-18       Impact factor: 4.616

8.  On-Chip Fluorescent Labeling using Reversed-phase Monoliths and Microchip Electrophoretic Separations of Selected Preterm Birth Biomarkers.

Authors:  Mukul Sonker; Rui Yang; Vishal Sahore; Suresh Kumar; Adam T Woolley
Journal:  Anal Methods       Date:  2016-09-30       Impact factor: 2.896

9.  Microfluidic chips with reversed-phase monoliths for solid phase extraction and on-chip labeling.

Authors:  Pamela N Nge; Jayson V Pagaduan; Ming Yu; Adam T Woolley
Journal:  J Chromatogr A       Date:  2012-09-01       Impact factor: 4.759

10.  Simultaneous capillary electrophoresis competitive immunoassay for insulin, glucagon, and islet amyloid polypeptide secretion from mouse islets of Langerhans.

Authors:  Christelle Guillo; Tuan M Truong; Michael G Roper
Journal:  J Chromatogr A       Date:  2011-05-13       Impact factor: 4.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.