Literature DB >> 28272749

Integrated electrokinetically driven microfluidic devices with pH-mediated solid-phase extraction coupled to microchip electrophoresis for preterm birth biomarkers.

Mukul Sonker1, Radim Knob1, Vishal Sahore1, Adam T Woolley1.   

Abstract

Integration in microfluidics is important for achieving automation. Sample preconcentration integrated with separation in a microfluidic setup can have a substantial impact on rapid analysis of low-abundance disease biomarkers. Here, we have developed a microfluidic device that uses pH-mediated solid-phase extraction (SPE) for the enrichment and elution of preterm birth (PTB) biomarkers. Furthermore, this SPE module was integrated with microchip electrophoresis for combined enrichment and separation of multiple analytes, including a PTB peptide biomarker (P1). A reversed-phase octyl methacrylate monolith was polymerized as the SPE medium in polyethylene glycol diacrylate modified cyclic olefin copolymer microfluidic channels. Eluent for pH-mediated SPE of PTB biomarkers on the monolith was optimized using different pH values and ionic concentrations. Nearly 50-fold enrichment was observed in single channel SPE devices for a low nanomolar solution of P1, with great elution time reproducibility (<7% RSD). The monolith binding capacity was determined to be 400 pg (0.2 pmol). A mixture of a model peptide (FA) and a PTB biomarker (P1) was extracted, eluted, injected, and then separated by microchip electrophoresis in our integrated device with ∼15-fold enrichment. This device shows important progress towards an integrated electrokinetically operated platform for preconcentration and separation of biomarkers.
© 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Enrichment; Integrated microfluidics; Microchip electrophoresis; Monoliths; Solid-phase extraction

Mesh:

Substances:

Year:  2017        PMID: 28272749      PMCID: PMC5541996          DOI: 10.1002/elps.201700054

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  60 in total

Review 1.  Integrated microfluidics platforms for investigating injury and regeneration of CNS axons.

Authors:  Hyung Joon Kim; Jeong Won Park; Jae Hwan Byun; Behrad Vahidi; Seog Woo Rhee; Noo Li Jeon
Journal:  Ann Biomed Eng       Date:  2012-06       Impact factor: 3.934

2.  Proteomic identification of serum peptides predicting subsequent spontaneous preterm birth.

Authors:  M Sean Esplin; Karen Merrell; Robert Goldenberg; Yinglei Lai; Jay D Iams; Brian Mercer; Catherine Y Spong; Menachem Miodovnik; Hygriv N Simhan; Peter van Dorsten; Mitchell Dombrowski
Journal:  Am J Obstet Gynecol       Date:  2010-11-11       Impact factor: 8.661

3.  Integrated multilayer microfluidic device with a nanoporous membrane interconnect for online coupling of solid-phase extraction to microchip electrophoresis.

Authors:  Zhicheng Long; Zheng Shen; Dapeng Wu; Jianhua Qin; Bingcheng Lin
Journal:  Lab Chip       Date:  2007-09-27       Impact factor: 6.799

4.  Microfluidic beads-based immunosensor for sensitive detection of cancer biomarker proteins using multienzyme-nanoparticle amplification and quantum dots labels.

Authors:  He Zhang; Lian Liu; Xin Fu; Zhenjun Zhu
Journal:  Biosens Bioelectron       Date:  2012-11-01       Impact factor: 10.618

Review 5.  Preterm labor: one syndrome, many causes.

Authors:  Roberto Romero; Sudhansu K Dey; Susan J Fisher
Journal:  Science       Date:  2014-08-14       Impact factor: 47.728

Review 6.  Advances in monoliths and related porous materials for microfluidics.

Authors:  Radim Knob; Vishal Sahore; Mukul Sonker; Adam T Woolley
Journal:  Biomicrofluidics       Date:  2016-05-04       Impact factor: 2.800

7.  Microfluidic chips with reversed-phase monoliths for solid phase extraction and on-chip labeling.

Authors:  Pamela N Nge; Jayson V Pagaduan; Ming Yu; Adam T Woolley
Journal:  J Chromatogr A       Date:  2012-09-01       Impact factor: 4.759

Review 8.  Biomarkers of Alzheimer's disease and mild cognitive impairment: a current perspective.

Authors:  Piotr Lewczuk; Barbara Mroczko; Anne Fagan; Johannes Kornhuber
Journal:  Adv Med Sci       Date:  2014-12-09       Impact factor: 3.287

9.  Affinity monolith preconcentrators for polymer microchip capillary electrophoresis.

Authors:  Weichun Yang; Xiuhua Sun; Tao Pan; Adam T Woolley
Journal:  Electrophoresis       Date:  2008-08       Impact factor: 3.535

10.  Affinity monolith-integrated poly(methyl methacrylate) microchips for on-line protein extraction and capillary electrophoresis.

Authors:  Xiuhua Sun; Weichun Yang; Tao Pan; Adam T Woolley
Journal:  Anal Chem       Date:  2008-05-15       Impact factor: 6.986

View more
  6 in total

1.  Advancement of analytical modes in a multichannel, microfluidic droplet-based sample chopper employing phase-locked detection.

Authors:  Jean T Negou; Juan Hu; Xiangpeng Li; Christopher J Easley
Journal:  Anal Methods       Date:  2018-06-05       Impact factor: 2.896

2.  Electrokinetically operated microfluidic devices for integrated immunoaffinity monolith extraction and electrophoretic separation of preterm birth biomarkers.

Authors:  Mukul Sonker; Ellen K Parker; Anna V Nielsen; Vishal Sahore; Adam T Woolley
Journal:  Analyst       Date:  2017-12-18       Impact factor: 4.616

Review 3.  Recent advances in microfluidic sample preparation and separation techniques for molecular biomarker analysis: A critical review.

Authors:  Mukul Sonker; Vishal Sahore; Adam T Woolley
Journal:  Anal Chim Acta       Date:  2017-07-24       Impact factor: 6.558

4.  Microchip electrophoresis separation of a panel of preterm birth biomarkers.

Authors:  Anna V Nielsen; Jacob B Nielsen; Mukul Sonker; Radim Knob; Vishal Sahore; Adam T Woolley
Journal:  Electrophoresis       Date:  2018-06-01       Impact factor: 3.535

5.  Automated microfluidic devices integrating solid-phase extraction, fluorescent labeling, and microchip electrophoresis for preterm birth biomarker analysis.

Authors:  Vishal Sahore; Mukul Sonker; Anna V Nielsen; Radim Knob; Suresh Kumar; Adam T Woolley
Journal:  Anal Bioanal Chem       Date:  2017-08-10       Impact factor: 4.142

6.  Analysis of thrombin-antithrombin complex formation using microchip electrophoresis and mass spectrometry.

Authors:  Jacob B Nielsen; Anna V Nielsen; Richard H Carson; Hsien-Jung L Lin; Robert L Hanson; Mukul Sonker; Daniel N Mortensen; John C Price; Adam T Woolley
Journal:  Electrophoresis       Date:  2019-08-13       Impact factor: 3.535

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.