Literature DB >> 28496521

On-Chip Fluorescent Labeling using Reversed-phase Monoliths and Microchip Electrophoretic Separations of Selected Preterm Birth Biomarkers.

Mukul Sonker1, Rui Yang1, Vishal Sahore1, Suresh Kumar1, Adam T Woolley1.   

Abstract

On-chip preconcentration, purification, and fluorescent labeling are desirable sample preparation steps to achieve complete automation in integrated microfluidic systems. In this work, we developed electrokinetically operated microfluidic devices for solid-phase extraction and fluorescent labeling of preterm birth (PTB) biomarkers. Reversed-phase monoliths based on different acrylate monomers were photopolymerized in cyclic olefin copolymer microdevices and studied for the selective retention and elution of a fluorescent dye and PTB biomarkers. Octyl methacrylate-based monoliths with desirable retention and elution characteristics were chosen and used for on-chip fluorescent labeling of three PTB biomarkers. Purification of on-chip labeled samples was done by selective elution of unreacted dye prior to sample. Automated and rapid on-chip fluorescent labeling was achieved with similar efficiency to that obtained for samples labeled off chip. Additionally, protocols for microchip electrophoresis of several off-chip-labeled PTB biomarkers were demonstrated in poly(methyl methacrylate) microfluidic devices. This study is an important step toward the development of integrated on-chip labeling and separation microfluidic devices for PTB biomarkers.

Entities:  

Year:  2016        PMID: 28496521      PMCID: PMC5421993          DOI: 10.1039/C6AY01803C

Source DB:  PubMed          Journal:  Anal Methods        ISSN: 1759-9660            Impact factor:   2.896


  56 in total

1.  On-line preconcentration in capillary electrochromatography using a porous monolith together with solvent gradient and sample stacking.

Authors:  J P Quirino; M T Dulay; R N Zare
Journal:  Anal Chem       Date:  2001-11-15       Impact factor: 6.986

2.  Proteomic identification of serum peptides predicting subsequent spontaneous preterm birth.

Authors:  M Sean Esplin; Karen Merrell; Robert Goldenberg; Yinglei Lai; Jay D Iams; Brian Mercer; Catherine Y Spong; Menachem Miodovnik; Hygriv N Simhan; Peter van Dorsten; Mitchell Dombrowski
Journal:  Am J Obstet Gynecol       Date:  2010-11-11       Impact factor: 8.661

3.  Integrated multilayer microfluidic device with a nanoporous membrane interconnect for online coupling of solid-phase extraction to microchip electrophoresis.

Authors:  Zhicheng Long; Zheng Shen; Dapeng Wu; Jianhua Qin; Bingcheng Lin
Journal:  Lab Chip       Date:  2007-09-27       Impact factor: 6.799

Review 4.  Enzymatic labeling of proteins: techniques and approaches.

Authors:  Mohammad Rashidian; Jonathan K Dozier; Mark D Distefano
Journal:  Bioconjug Chem       Date:  2013-08-21       Impact factor: 4.774

5.  Microfluidic beads-based immunosensor for sensitive detection of cancer biomarker proteins using multienzyme-nanoparticle amplification and quantum dots labels.

Authors:  He Zhang; Lian Liu; Xin Fu; Zhenjun Zhu
Journal:  Biosens Bioelectron       Date:  2012-11-01       Impact factor: 10.618

Review 6.  Preterm labor: one syndrome, many causes.

Authors:  Roberto Romero; Sudhansu K Dey; Susan J Fisher
Journal:  Science       Date:  2014-08-14       Impact factor: 47.728

7.  A simple method for displaying the hydropathic character of a protein.

Authors:  J Kyte; R F Doolittle
Journal:  J Mol Biol       Date:  1982-05-05       Impact factor: 5.469

8.  Microfluidic chips with reversed-phase monoliths for solid phase extraction and on-chip labeling.

Authors:  Pamela N Nge; Jayson V Pagaduan; Ming Yu; Adam T Woolley
Journal:  J Chromatogr A       Date:  2012-09-01       Impact factor: 4.759

9.  Temperature-swing solid-phase extraction of heavy metals on a poly(N-isopropylacrylamide) hydrogel.

Authors:  Hideaki Tokuyama; Takahiko Iwama
Journal:  Langmuir       Date:  2007-11-14       Impact factor: 3.882

10.  Affinity monolith-integrated poly(methyl methacrylate) microchips for on-line protein extraction and capillary electrophoresis.

Authors:  Xiuhua Sun; Weichun Yang; Tao Pan; Adam T Woolley
Journal:  Anal Chem       Date:  2008-05-15       Impact factor: 6.986

View more
  7 in total

1.  Sequence-specific sepsis-related DNA capture and fluorescent labeling in monoliths prepared by single-step photopolymerization in microfluidic devices.

Authors:  Radim Knob; Robert L Hanson; Olivia B Tateoka; Ryan L Wood; Israel Guerrero-Arguero; Richard A Robison; William G Pitt; Adam T Woolley
Journal:  J Chromatogr A       Date:  2018-05-21       Impact factor: 4.759

2.  Sequence-specific DNA solid-phase extraction in an on-chip monolith: Towards detection of antibiotic resistance genes.

Authors:  Radim Knob; Daniel B Nelson; Richard A Robison; Adam T Woolley
Journal:  J Chromatogr A       Date:  2017-07-10       Impact factor: 4.759

3.  Integrated electrokinetically driven microfluidic devices with pH-mediated solid-phase extraction coupled to microchip electrophoresis for preterm birth biomarkers.

Authors:  Mukul Sonker; Radim Knob; Vishal Sahore; Adam T Woolley
Journal:  Electrophoresis       Date:  2017-04-25       Impact factor: 3.535

4.  Electrokinetically operated microfluidic devices for integrated immunoaffinity monolith extraction and electrophoretic separation of preterm birth biomarkers.

Authors:  Mukul Sonker; Ellen K Parker; Anna V Nielsen; Vishal Sahore; Adam T Woolley
Journal:  Analyst       Date:  2017-12-18       Impact factor: 4.616

Review 5.  Recent advances in microfluidic sample preparation and separation techniques for molecular biomarker analysis: A critical review.

Authors:  Mukul Sonker; Vishal Sahore; Adam T Woolley
Journal:  Anal Chim Acta       Date:  2017-07-24       Impact factor: 6.558

6.  Microchip electrophoresis separation of a panel of preterm birth biomarkers.

Authors:  Anna V Nielsen; Jacob B Nielsen; Mukul Sonker; Radim Knob; Vishal Sahore; Adam T Woolley
Journal:  Electrophoresis       Date:  2018-06-01       Impact factor: 3.535

7.  Automated microfluidic devices integrating solid-phase extraction, fluorescent labeling, and microchip electrophoresis for preterm birth biomarker analysis.

Authors:  Vishal Sahore; Mukul Sonker; Anna V Nielsen; Radim Knob; Suresh Kumar; Adam T Woolley
Journal:  Anal Bioanal Chem       Date:  2017-08-10       Impact factor: 4.142

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.