Literature DB >> 27042251

A multiplexed immunoaggregation biomarker assay using a two-stage micro resistive pulse sensor.

Y Han1, H Wu2, F Liu1, G Cheng2, J Zhe1.   

Abstract

We present an immunoaggregation assay chip for multiplexed biomarkers detection. This chip is based on immunoaggregation of antibody functionalized microparticles (Ab-MPs) to quantify concentrations of multiple biomarkers simultaneously. A mixture of multiple types of Ab-MPs probes with different sizes and magnetic properties, which were functionalized by different antibodies, was used for the multiplexed assay. The interactions between biomarkers and their specific Ab-MPs probes caused the immunoaggregation of Ab-MPs. A two-stage micro resistive pulse sensor was used to differentiate and count the Ab-MP aggregates triggered by different biomarkers via size and magnetic property for multiplexed detection. The volume fraction of each type of Ab-MP aggregates indicates the concentration of the corresponding target biomarker. In our study, we demonstrated multiplexed detection of two model biomarkers (human ferritin and mouse anti-rabbit IgG) in 10% fetal bovine serum, using anti-ferritin Ab and anti-mouse IgG Ab functionalized MPs. We found that the volume fraction of Ab-MP aggregates increased with the increased biomarker concentrations. The detection ranges from 5.2 ng/ml to 208 ng/ml and 3.1 ng/ml to 5.12 × 10(4 )ng/ml were achieved for human ferritin and mouse anti-rabbit IgG. This bioassay chip is able to quantitatively detect multiple biomarkers in a single test without fluorescence or enzymatic labeling process and hence is promising to serve as a useful tool for rapid detection of multiple biomarkers in biomedical research and clinical applications.

Entities:  

Year:  2016        PMID: 27042251      PMCID: PMC4798986          DOI: 10.1063/1.4944456

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  50 in total

1.  An electrochemical detection scheme for identification of single nucleotide polymorphisms using hairpin-forming probes.

Authors:  Tony Jun Huang; Minghsun Liu; Linda D Knight; Wayne W Grody; Jeff F Miller; Chih-Ming Ho
Journal:  Nucleic Acids Res       Date:  2002-06-15       Impact factor: 16.971

2.  Colorimetric multiplexed immunoassay using specific aggregation of antigenic peptide-modified luminous nanoparticles.

Authors:  Toshihiro Ihara; Yasunori Mori; Takaaki Imamura; Motoko Mukae; Shojiro Tanaka; Akinori Jyo
Journal:  Anal Chim Acta       Date:  2006-05-04       Impact factor: 6.558

3.  Two dimensional barcode-inspired automatic analysis for arrayed microfluidic immunoassays.

Authors:  Yi Zhang; Lingbo Qiao; Yunke Ren; Xuwei Wang; Ming Gao; Yunfang Tang; Jianzhong Jeff Xi; Tzung-May Fu; Xingyu Jiang
Journal:  Biomicrofluidics       Date:  2013-06-13       Impact factor: 2.800

4.  A droplet-based novel approach for viable and low volume consumption surface plasmon resonance bio-sensing inside a polydimethylsiloxane microchip.

Authors:  T Ghosh; Y Xie; C Mastrangelo
Journal:  Biomicrofluidics       Date:  2013-08-21       Impact factor: 2.800

Review 5.  Interface design and multiplexed analysis with surface plasmon resonance (SPR) spectroscopy and SPR imaging.

Authors:  Matthew J Linman; Abdennour Abbas; Quan Cheng
Journal:  Analyst       Date:  2010-09-07       Impact factor: 4.616

6.  QCM immunoassay for recombinant cysteine peptidase: a potential protein biomarker for diagnosis of citrus canker.

Authors:  André S Afonso; Bianca F Zanetti; Adelita C Santiago; Flavio Henrique-Silva; Luiz H C Mattoso; Ronaldo C Faria
Journal:  Talanta       Date:  2012-11-13       Impact factor: 6.057

Review 7.  Electrochemical immunosensors for detection of cancer protein biomarkers.

Authors:  Bhaskara V Chikkaveeraiah; Ashwinkumar A Bhirde; Nicole Y Morgan; Henry S Eden; Xiaoyuan Chen
Journal:  ACS Nano       Date:  2012-08-06       Impact factor: 15.881

8.  Multiple biomarker strategy for improved diagnosis of acute heart failure in older patients presenting to the emergency department.

Authors:  Philipp Bahrmann; Anke Bahrmann; Benjamin Hofner; Michael Christ; Stephan Achenbach; Cornel Christian Sieber; Thomas Bertsch
Journal:  Eur Heart J Acute Cardiovasc Care       Date:  2014-07-07

9.  Multiplexed immunoassay: quantitation and profiling of serum biomarkers using magnetic nanoprobes and MALDI-TOF MS.

Authors:  Kai-Yi Wang; Szu-An Chuang; Po-Chiao Lin; Li-Shing Huang; Shu-Hua Chen; Saib Ouarda; Wen-Harn Pan; Ping-Ying Lee; Chun-Cheng Lin; Yu-Ju Chen
Journal:  Anal Chem       Date:  2008-07-22       Impact factor: 6.986

10.  Label-free biomarker assay in a microresistive pulse sensor via immunoaggregation.

Authors:  Yu Han; Haiyan Wu; Fan Liu; Gang Cheng; Jiang Zhe
Journal:  Anal Chem       Date:  2014-09-16       Impact factor: 6.986

View more
  3 in total

1.  A microfluidic competitive immuno-aggregation assay for high sensitivity cell secretome detection.

Authors:  Fan Liu; Pawan Kc; Liwei Ni; Ge Zhang; Jiang Zhe
Journal:  Organogenesis       Date:  2018-06-08       Impact factor: 2.500

Review 2.  Lab-on-a-chip electrical multiplexing techniques for cellular and molecular biomarker detection.

Authors:  Fan Liu; Liwei Ni; Jiang Zhe
Journal:  Biomicrofluidics       Date:  2018-04-10       Impact factor: 2.800

3.  A Low-Cost Micro-Volume Nephelometric System for Quantitative Immunoagglutination Assays.

Authors:  Qiqi Sun; Wei Zheng; Chao Lin; Dongxuan Shen
Journal:  Sensors (Basel)       Date:  2019-10-09       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.