Catching errors with in vivo EPID dosimetry.

A Mans1, M Wendling, L N McDermott, J J Sonke, R Tielenburg, R Vijlbrief, B Mijnheer, M van Herk, J C Stroom.   

Abstract

The potential for detrimental incidents and the ever increasing complexity of patient treatments emphasize the need for accurate dosimetric verification in radiotherapy. For this reason, all curative treatments are verified, either pretreatment or in vivo, by electronic portal imaging device (EPID) dosimetry in the Radiation Oncology Department of The Netherlands Cancer Institute-Antoni van Leeuwenhoek hospital, Amsterdam, The Netherlands. Since the clinical introduction of the method in January 2005 until August 2009, treatment plans of 4337 patients have been verified. Among these plans, 17 serious errors were detected that led to intervention. Due to their origin, nine of these errors would not have been detected with pretreatment verification. The method is illustrated in detail by the case of a plan transfer error detected in a 5 x 5 Gy intensity-modulated radiotherapy (IMRT) rectum treatment. The EPID reconstructed dose at the isocenter was 6.3% below the planned value. Investigation of the plan transfer chain revealed that due to a network transfer error, the plan was corrupted. 3D analysis of the acquired EPID data revealed serious underdosage of the planning target volume: On average 11.6%, locally up to 20%. This report shows the importance of in vivo (EPID) dosimetry for all treatment plans as well as the ability of the method to assess the dosimetric impact of deviations found.

Entities:  

Mesh:

Year:  2010        PMID: 20632575     DOI: 10.1118/1.3397807

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  43 in total

1.  Safety strategies in an academic radiation oncology department and recommendations for action.

Authors:  Stephanie A Terezakis; Peter Pronovost; Kendra Harris; Theodore Deweese; Eric Ford
Journal:  Jt Comm J Qual Patient Saf       Date:  2011-07

2.  A dual two dimensional electronic portal imaging device transit dosimetry model based on an empirical quadratic formalism.

Authors:  Y I Tan; M Metwaly; M Glegg; S P Baggarley; A Elliott
Journal:  Br J Radiol       Date:  2015-05-13       Impact factor: 3.039

3.  An evaluation of techniques for dose calculation on cone beam computed tomography.

Authors:  Valentina Giacometti; Raymond B King; Christina E Agnew; Denise M Irvine; Suneil Jain; Alan R Hounsell; Conor K McGarry
Journal:  Br J Radiol       Date:  2019-02-26       Impact factor: 3.039

4.  A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.

Authors:  Christos Moustakis; Fatemeh Ebrahimi Tazehmahalleh; Khaled Elsayad; Francis Fezeu; Sergiu Scobioala
Journal:  Strahlenther Onkol       Date:  2020-01-10       Impact factor: 3.621

5.  Uncertainties encountered in implementation of adaptive planning with in vivo dosimeters.

Authors:  M T Studenski; S J Gardner; R B Den
Journal:  Radiol Phys Technol       Date:  2014-09-19

6.  The report of Task Group 100 of the AAPM: Application of risk analysis methods to radiation therapy quality management.

Authors:  M Saiful Huq; Benedick A Fraass; Peter B Dunscombe; John P Gibbons; Geoffrey S Ibbott; Arno J Mundt; Sasa Mutic; Jatinder R Palta; Frank Rath; Bruce R Thomadsen; Jeffrey F Williamson; Ellen D Yorke
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

7.  Dose verification of volumetric modulated arc therapy (VMAT) by use of in-treatment linac parameters.

Authors:  Akihiro Haga; Akira Sakumi; Yukari Okano; Saori Itoh; Naoya Saotome; Satoshi Kida; Hiroshi Igaki; Kenshiro Shiraishi; Hideomi Yamashita; Kuni Ohtomo; Keiichi Nakagawa
Journal:  Radiol Phys Technol       Date:  2013-03-12

8.  Transit dosimetry in dynamic IMRT with an a-Si EPID.

Authors:  Mahsheed Sabet; Pejman Rowshanfarzad; Fred W Menk; Peter B Greer
Journal:  Med Biol Eng Comput       Date:  2014-05-31       Impact factor: 2.602

9.  Commissioning and Evaluation of an Electronic Portal Imaging Device-Based In-Vivo Dosimetry Software.

Authors:  Mareike Held; Joey Cheung; Angelica Perez Andujar; François Husson; Olivier Morin
Journal:  Cureus       Date:  2018-02-02

10.  Improved error detection using a divided treatment plan in volume modulated arc therapy.

Authors:  Kazuo Tarutani; Masao Tanooka; Hiroshi Doi; Masayuki Fujiwara; Masaki Miyashita; Kazufumi Kagawa; Norihiko Kamikonya; Koichiro Yamakado
Journal:  Rep Pract Oncol Radiother       Date:  2019-01-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.