Literature DB >> 25236778

Uncertainties encountered in implementation of adaptive planning with in vivo dosimeters.

M T Studenski1, S J Gardner, R B Den.   

Abstract

Under a previously approved institutional review board protocol for prostate cancer patients, implanted metal-oxide semiconductor field-effect transistor dosimeters (dose verification system, Sicel Technologies) were used for measurement of the in vivo delivered daily dose. This dosimetric information provided the ability to adapt the plan if the measured doses did not match the dose expected from the planning system. Due to the inherent uncertainty in the dosimeters, the decision to adapt the treatment plan was made only if readings differed by more than 7 % for three consecutive days. To validate this method, we acquired daily cone beam computed tomography images for five patients, and the dose delivered to the dosimeters was calculated by use of (1) an automated procedure (MIM Maestro, MIM Software) and (2) the treatment planning system (XIO, Elekta). 72 % of the doses calculated automatically fell within 1 % of the doses calculated in the planning system, and 99 % agreed within 2 %. When compared to the calculated dose, 53 % of the in vivo measurements fell within 3 % of the calculated dose, 80 % fell within 5 %, and 9.8 % were greater than 7 %, but never on three consecutive days. The measured doses agreed reasonably well with the calculated doses, supporting the decision to adapt the plan only if there were discrepancies of more than 7 % over three consecutive days. Even with the inherent uncertainty in the dosimeters, this adaptive planning method can detect delivery inaccuracies that would not otherwise be caught with the use of only daily image guidance or other dose calculation surrogates.

Entities:  

Mesh:

Year:  2014        PMID: 25236778     DOI: 10.1007/s12194-014-0291-0

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  17 in total

1.  Implanted dosimeters identify radiation overdoses during IMRT for prostate cancer.

Authors:  Robert B Den; Kamila Nowak; Ivan Buzurovic; Junsheng Cao; Amy S Harrison; Yaacov R Lawrence; Adam P Dicker; Timothy N Showalter
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-07-01       Impact factor: 7.038

2.  On-line re-optimization of prostate IMRT plans for adaptive radiation therapy.

Authors:  Q Jackie Wu; Danthai Thongphiew; Zhiheng Wang; Boonyanit Mathayomchan; Vira Chankong; Sua Yoo; W Robert Lee; Fang-Fang Yin
Journal:  Phys Med Biol       Date:  2008-01-10       Impact factor: 3.609

3.  Scale invariant feature transform in adaptive radiation therapy: a tool for deformable image registration assessment and re-planning indication.

Authors:  Chiara Paganelli; Marta Peroni; Marco Riboldi; Gregory C Sharp; Delia Ciardo; Daniela Alterio; Roberto Orecchia; Guido Baroni
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

4.  Combined online and offline adaptive radiation therapy: a dosimetric feasibility study.

Authors:  Chengliang Yang; Feng Liu; Ergun Ahunbay; Yu-Wen Chang; Colleen Lawton; Christopher Schultz; Dian Wang; Selim Firat; Beth Erickson; X Allen Li
Journal:  Pract Radiat Oncol       Date:  2013-04-10

5.  Initial clinical results of an in vivo dosimeter during external beam radiation therapy.

Authors:  Charles W Scarantino; Christopher J Rini; Migdalia Aquino; Tammy B Carrea; Robert D Ornitz; Mitchell S Anscher; Robert D Black
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-06-01       Impact factor: 7.038

6.  Volumetric image-guidance: does routine usage prompt adaptive re-planning? An institutional review.

Authors:  James A Tanyi; Martin H Fuss
Journal:  Acta Oncol       Date:  2008       Impact factor: 4.089

7.  Volume and dosimetric changes and initial clinical experience of a two-step adaptive intensity modulated radiation therapy (IMRT) scheme for head and neck cancer.

Authors:  Tamaki Nishi; Yasumasa Nishimura; Toru Shibata; Masaya Tamura; Naohiro Nishigaito; Masahiko Okumura
Journal:  Radiother Oncol       Date:  2013-01-19       Impact factor: 6.280

8.  Technical evaluation of radiation dose delivered in prostate cancer patients as measured by an implantable MOSFET dosimeter.

Authors:  Gloria P Beyer; Charles W Scarantino; Bradley R Prestidge; Amir G Sadeghi; Mitchell S Anscher; Moyed Miften; Tammy B Carrea; Marianne Sims; Robert D Black
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-01       Impact factor: 7.038

9.  A study on adaptive IMRT treatment planning using kV cone-beam CT.

Authors:  George X Ding; Dennis M Duggan; Charles W Coffey; Matthew Deeley; Dennis E Hallahan; Anthony Cmelak; Arnold Malcolm
Journal:  Radiother Oncol       Date:  2007-08-20       Impact factor: 6.280

10.  Commissioning and implementation of an implantable dosimeter for radiation therapy.

Authors:  Ivan Buzurovic; Timothy N Showalter; Matthew T Studenski; Robert B Den; Adam P Dicker; Junsheng Cao; Ying Xiao; Yan Yu; Amy Harrison
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

View more
  1 in total

1.  18F-Choline PET/MRI: The Additional Value of PET for MRI-Guided Transrectal Prostate Biopsies.

Authors:  Morand Piert; Jeffrey Montgomery; Lakshmi Priya Kunju; Javed Siddiqui; Virginia Rogers; Thekkelnaycke Rajendiran; Timothy D Johnson; Xia Shao; Matthew S Davenport
Journal:  J Nucl Med       Date:  2016-03-16       Impact factor: 10.057

  1 in total