Commissioning and Evaluation of an Electronic Portal Imaging Device-Based In-Vivo Dosimetry Software.

Mareike Held1, Joey Cheung1, Angelica Perez Andujar1, François Husson2, Olivier Morin1.   

Abstract

This study reports on our experience with the in-vivo dose verification software, EPIgray® (DOSIsoft, Cachan, France). After the initial commissioning process, clinical experiments on phantom treatments were evaluated to assess the level of accuracy of the electronic portal imaging device (EPID) based in-vivo dose verification. EPIgray was commissioned based on the company's instructions. This involved ion chamber measurements and portal imaging of solid water blocks of various thicknesses between 5 and 35 cm. Field sizes varied between 2 x 2 cm2 and 20 x 20 cm2. The determined conversion factors were adjusted through an additional iterative process using treatment planning system calculations. Subsequently, evaluation was performed using treatment plans of single and opposed beams, as well as intensity modulated radiotherapy (IMRT) plans, based on recommendations from the task group report TG-119 to test for dose reconstruction accuracy. All tests were performed using blocks of solid water slabs as a phantom. For single square fields, the dose at isocenter was reconstructed within 3% accuracy in EPIgray compared to the treatment planning system dose. Similarly, the relative deviation of the total dose was accurately reconstructed within 3% for all IMRT plans with points placed inside a high-dose region near the isocenter. Predictions became less accurate than < 5% when the evaluation point was outside the treatment target. Dose at points 5 cm or more away from the isocenter or within an avoidance structure was reconstructed less reliably. EPIgray formalism accuracy is adequate for an efficient error detection system with verifications performed in high-dose volumes. It provides immediate intra-fractional feedback on the delivery of treatment plans without affecting the treatment beam. Besides the EPID, no additional hardware is required. The software evaluates local point dose measurements to verify treatment plan delivery and patient positioning within 5% accuracy, depending on the placement of evaluation points.

Entities:  

Keywords:  epid; external beam radiotherapy; finite tissue maximum ratio (ftmr); in-vivo dosimetry; quality assurance

Year:  2018        PMID: 29632749      PMCID: PMC5880591          DOI: 10.7759/cureus.2139

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  22 in total

1.  Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device.

Authors:  K L Pasma; M L Dirkx; M Kroonwijk; A G Visser; B J Heijmen
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields.

Authors:  A Van Esch; B Vanstraelen; J Verstraete; G Kutcher; D Huyskens
Journal:  Radiother Oncol       Date:  2001-08       Impact factor: 6.280

3.  Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58.

Authors:  M G Herman; J M Balter; D A Jaffray; K P McGee; P Munro; S Shalev; M Van Herk; J W Wong
Journal:  Med Phys       Date:  2001-05       Impact factor: 4.071

4.  Dosimetric IMRT verification with a flat-panel EPID.

Authors:  B Warkentin; S Steciw; S Rathee; B G Fallone
Journal:  Med Phys       Date:  2003-12       Impact factor: 4.071

5.  Calibration of an amorphous-silicon flat panel portal imager for exit-beam dosimetry.

Authors:  Josephine Chen; Cynthia F Chuang; Olivier Morin; Michèle Aubin; Jean Pouliot
Journal:  Med Phys       Date:  2006-03       Impact factor: 4.071

Review 6.  A literature review of electronic portal imaging for radiotherapy dosimetry.

Authors:  Wouter van Elmpt; Leah McDermott; Sebastiaan Nijsten; Markus Wendling; Philippe Lambin; Ben Mijnheer
Journal:  Radiother Oncol       Date:  2008-08-14       Impact factor: 6.280

7.  Low-dose megavoltage cone-beam CT for radiation therapy.

Authors:  Jean Pouliot; Ali Bani-Hashemi; Josephine Chen; Michelle Svatos; Farhad Ghelmansarai; Matthias Mitschke; Michele Aubin; Ping Xia; Olivier Morin; Kara Bucci; Mack Roach; Paco Hernandez; Zirao Zheng; Dimitre Hristov; Lynn Verhey
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-02-01       Impact factor: 7.038

Review 8.  In vivo dosimetry in external beam radiotherapy.

Authors:  Ben Mijnheer; Sam Beddar; Joanna Izewska; Chester Reft
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

9.  Treatment verification in the presence of inhomogeneities using EPID-based three-dimensional dose reconstruction.

Authors:  Wouter J C van Elmpt; Sebastiaan M J J G Nijsten; André L A J Dekker; Ben J Mijnheer; Philippe Lambin
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

10.  EPID based in vivo dosimetry system: clinical experience and results.

Authors:  Sofia Celi; Emilie Costa; Claas Wessels; Alejandro Mazal; Alain Fourquet; Pascal Francois
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

View more
  2 in total

1.  Clinical pilot study for EPID-based in vivo dosimetry using EPIgray™ for head and neck VMAT.

Authors:  Sophie D Halliday; Rebecca A Day; Lynne Greig; Robert J W Louwe
Journal:  Phys Eng Sci Med       Date:  2022-10-13

Review 2.  In vivo dosimetry in external beam photon radiotherapy: Requirements and future directions for research, development, and clinical practice.

Authors:  Igor Olaciregui-Ruiz; Sam Beddar; Peter Greer; Nuria Jornet; Boyd McCurdy; Gabriel Paiva-Fonseca; Ben Mijnheer; Frank Verhaegen
Journal:  Phys Imaging Radiat Oncol       Date:  2020-08-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.