Literature DB >> 20588737

3D refraction correction and extraction of clinical parameters from spectral domain optical coherence tomography of the cornea.

Mingtao Zhao1, Anthony N Kuo, Joseph A Izatt.   

Abstract

Capable of three-dimensional imaging of the cornea with micrometer-scale resolution, spectral domain-optical coherence tomography (SDOCT) offers potential advantages over Placido ring and Scheimpflug photography based systems for accurate extraction of quantitative keratometric parameters. In this work, an SDOCT scanning protocol and motion correction algorithm were implemented to minimize the effects of patient motion during data acquisition. Procedures are described for correction of image data artifacts resulting from 3D refraction of SDOCT light in the cornea and from non-idealities of the scanning system geometry performed as a pre-requisite for accurate parameter extraction. Zernike polynomial 3D reconstruction and a recursive half searching algorithm (RHSA) were implemented to extract clinical keratometric parameters including anterior and posterior radii of curvature, central cornea optical power, central corneal thickness, and thickness maps of the cornea. Accuracy and repeatability of the extracted parameters obtained using a commercial 859nm SDOCT retinal imaging system with a corneal adapter were assessed using a rigid gas permeable (RGP) contact lens as a phantom target. Extraction of these parameters was performed in vivo in 3 patients and compared to commercial Placido topography and Scheimpflug photography systems. The repeatability of SDOCT central corneal power measured in vivo was 0.18 Diopters, and the difference observed between the systems averaged 0.1 Diopters between SDOCT and Scheimpflug photography, and 0.6 Diopters between SDOCT and Placido topography.

Entities:  

Mesh:

Year:  2010        PMID: 20588737     DOI: 10.1364/OE.18.008923

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  38 in total

1.  Simultaneous swept source optical coherence tomography of the anterior segment and retina using coherence revival.

Authors:  Al-Hafeez Dhalla; Derek Nankivil; Theresa Bustamante; Anthony Kuo; Joseph A Izatt
Journal:  Opt Lett       Date:  2012-06-01       Impact factor: 3.776

2.  Calculation of crystalline lens power using a modification of the Bennett method.

Authors:  Victor M Hernandez; Florence Cabot; Marco Ruggeri; Carolina de Freitas; Arthur Ho; Sonia Yoo; Jean-Marie Parel; Fabrice Manns
Journal:  Biomed Opt Express       Date:  2015-10-21       Impact factor: 3.732

3.  OCT-based crystalline lens topography in accommodating eyes.

Authors:  Pablo Pérez-Merino; Miriam Velasco-Ocana; Eduardo Martinez-Enriquez; Susana Marcos
Journal:  Biomed Opt Express       Date:  2015-11-24       Impact factor: 3.732

4.  Extended scan depth optical coherence tomography for evaluating ocular surface shape.

Authors:  Meixiao Shen; Lele Cui; Ming Li; Dexi Zhu; Michael R Wang; Jianhua Wang
Journal:  J Biomed Opt       Date:  2011-05       Impact factor: 3.170

5.  Topographic thickness of Bowman's layer determined by ultra-high resolution spectral domain-optical coherence tomography.

Authors:  Aizhu Tao; Jianhua Wang; Qi Chen; Meixiao Shen; Fan Lu; Sander R Dubovy; Mohamed Abou Shousha
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-01       Impact factor: 4.799

6.  Wide-field whole eye OCT system with demonstration of quantitative retinal curvature estimation.

Authors:  Ryan P McNabb; James Polans; Brenton Keller; Moseph Jackson-Atogi; Charlene L James; Robin R Vann; Joseph A Izatt; Anthony N Kuo
Journal:  Biomed Opt Express       Date:  2018-12-21       Impact factor: 3.732

7.  Golden angle based scanning for robust corneal topography with OCT.

Authors:  Joerg Wagner; David Goldblum; Philippe C Cattin
Journal:  Biomed Opt Express       Date:  2017-01-03       Impact factor: 3.732

8.  Topography and pachymetry maps for mouse corneas using optical coherence tomography.

Authors:  Alice S Liu; Dillon M Brown; Rachel E Conn; Ryan P McNabb; Machelle T Pardue; Anthony N Kuo
Journal:  Exp Eye Res       Date:  2019-11-05       Impact factor: 3.467

9.  Optical coherence tomography accurately measures corneal power change from laser refractive surgery.

Authors:  Ryan P McNabb; Sina Farsiu; Sandra S Stinnett; Joseph A Izatt; Anthony N Kuo
Journal:  Ophthalmology       Date:  2014-12-06       Impact factor: 12.079

10.  Anterior segment biometry during accommodation imaged with ultralong scan depth optical coherence tomography.

Authors:  Chixin Du; Meixiao Shen; Ming Li; Dexi Zhu; Michael R Wang; Jianhua Wang
Journal:  Ophthalmology       Date:  2012-08-17       Impact factor: 12.079

View more