Golden angle based scanning for robust corneal topography with OCT.

Joerg Wagner1, David Goldblum2, Philippe C Cattin1.   

Abstract

Corneal topography allows the assessment of the cornea's refractive power which is crucial for diagnostics and surgical planning. The use of optical coherence tomography (OCT) for corneal topography is still limited. One limitation is the susceptibility to disturbances like blinking of the eye. This can result in partially corrupted scans that cannot be evaluated using common methods. We present a new scanning method for reliable corneal topography from partial scans. Based on the golden angle, the method features a balanced scan point distribution which refines over measurement time and remains balanced when part of the scan is removed. The performance of the method is assessed numerically and by measurements of test surfaces. The results confirm that the method enables numerically well-conditioned and reliable corneal topography from partially corrupted scans and reduces the need for repeated measurements in case of abrupt disturbances.

Entities:  

Keywords:  (100.6950) Tomographic image processing; (170.4470) Ophthalmology; (170.4500) Optical coherence tomography; (170.4580) Optical diagnostics for medicine

Year:  2017        PMID: 28270961      PMCID: PMC5330583          DOI: 10.1364/BOE.8.000475

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  13 in total

1.  Instantaneous complex conjugate resolved spectral domain and swept-source OCT using 3x3 fiber couplers.

Authors:  Marinko Sarunic; Michael A Choma; Changhuei Yang; Joseph A Izatt
Journal:  Opt Express       Date:  2005-02-07       Impact factor: 3.894

2.  Computing confidence intervals for standardized regression coefficients.

Authors:  Jeff A Jones; Niels G Waller
Journal:  Psychol Methods       Date:  2013-09-30

3.  Direct and inverse discrete Zernike transform.

Authors:  Rafael Navarro; Justo Arines; Ricardo Rivera
Journal:  Opt Express       Date:  2009-12-21       Impact factor: 3.894

4.  Corneal topography of early keratoconus.

Authors:  L J Maguire; W M Bourne
Journal:  Am J Ophthalmol       Date:  1989-08-15       Impact factor: 5.258

5.  Corneal power measurement with Fourier-domain optical coherence tomography.

Authors:  Maolong Tang; Alex Chen; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2010-12       Impact factor: 3.351

6.  Goodness-of-prediction of Zernike polynomial fitting to corneal surfaces.

Authors:  Michael K Smolek; Stephen D Klyce
Journal:  J Cataract Refract Surg       Date:  2005-12       Impact factor: 3.351

7.  Distributed scanning volumetric SDOCT for motion corrected corneal biometry.

Authors:  Ryan P McNabb; Francesco Larocca; Sina Farsiu; Anthony N Kuo; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2012-08-10       Impact factor: 3.732

8.  Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming.

Authors:  Francesco Larocca; Stephanie J Chiu; Ryan P McNabb; Anthony N Kuo; Joseph A Izatt; Sina Farsiu
Journal:  Biomed Opt Express       Date:  2011-05-12       Impact factor: 3.732

9.  Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patterns.

Authors:  Martin F Kraus; Benjamin Potsaid; Markus A Mayer; Ruediger Bock; Bernhard Baumann; Jonathan J Liu; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2012-05-03       Impact factor: 3.732

10.  Quantitative OCT-based corneal topography in keratoconus with intracorneal ring segments.

Authors:  Sergio Ortiz; Pablo Pérez-Merino; Nicolas Alejandre; E Gambra; I Jimenez-Alfaro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2012-04-02       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.