Literature DB >> 22902211

Anterior segment biometry during accommodation imaged with ultralong scan depth optical coherence tomography.

Chixin Du1, Meixiao Shen, Ming Li, Dexi Zhu, Michael R Wang, Jianhua Wang.   

Abstract

PURPOSE: To measure by ultralong scan depth optical coherence tomography (UL-OCT) dimensional changes in the anterior segment of human eyes during accommodation.
DESIGN: Evaluation of diagnostic test or technology. PARTICIPANTS: Forty-one right eyes of healthy subjects with a mean age of 34 years (range, 22-41 years) and a mean refraction of -2.5 ± 2.6 diopters were imaged in 2 repeated measurements at minimal and maximal accommodations.
METHODS: A specially adapted and designed UL-OCT instrument was used to image from the front surface of the cornea to the back surface of the crystalline lens. Custom software corrected the optical distortion of the images and yielded the biometric measurements. The coefficient of repeatability and the intraclass correlation coefficient were calculated to evaluate the repeatability and reliability. MAIN OUTCOME MEASURES: Anterior segment parameters and associated repeatability and reliability upon accommodation. The dimensional results included central corneal thickness (CCT), anterior chamber depth and width (ACD, ACW), pupil diameter (PD), lens thickness (LT), anterior segment length (ASL = ACD + LT), lens central position (LCP = ACD + 1/2LT), and horizontal radii of the lens anterior and posterior surface curvatures (LAC, LPC).
RESULTS: Repeated measurements of each variable within each accommodative state did not differ significantly (P>0.05). The coefficients of repeatability (CORs) and intraclass correlation coefficients for CCT, ACW, ACD, LT, LCP, and ASL were excellent (1.2%- 3.59% and 0.998-0.877, respectively). They were higher for PD (18.90%-21.63% and 0.880-0.874, respectively) and moderate for LAC and LPC (34.86%-42.72% and 0.669-0.251, respectively) in the 2 accommodative states. Compared with minimal accommodation, PD, ACD, LAC, LPC, and LCP decreased and LT and ASL increased significantly at maximal accommodation (P<0.05), whereas CCT and ACW did not change (P>0.05).
CONCLUSIONS: The UL-OCT measured changes in anterior segment dimensions during accommodation with good repeatability and reliability. During accommodation, the back surface of the lens became steeper as the lens moved forward. FINANCIAL DISCLOSURE(S): The authors have no proprietary or commercial interest in any of the materials discussed in this article.
Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22902211      PMCID: PMC3505244          DOI: 10.1016/j.ophtha.2012.06.041

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  32 in total

1.  The mechanism of accommodation in primates.

Authors:  A Glasser; P L Kaufman
Journal:  Ophthalmology       Date:  1999-05       Impact factor: 12.079

2.  Anterior chamber width measurement by high-speed optical coherence tomography.

Authors:  Jason A Goldsmith; Yan Li; Maria Regina Chalita; Volker Westphal; Chetan A Patil; Andrew M Rollins; Joseph A Izatt; David Huang
Journal:  Ophthalmology       Date:  2005-02       Impact factor: 12.079

Review 3.  Advances in anterior segment imaging.

Authors:  James S Wolffsohn; Leon N Davies
Journal:  Curr Opin Ophthalmol       Date:  2007-02       Impact factor: 3.761

4.  Large depth-high resolution full 3D imaging of the anterior segments of the eye using high speed optical frequency domain imaging.

Authors:  C Kerbage; H Lim; W Sun; M Mujat; J F de Boer
Journal:  Opt Express       Date:  2007-06-11       Impact factor: 3.894

5.  MRI study of the changes in crystalline lens shape with accommodation and aging in humans.

Authors:  Sanjeev Kasthurirangan; Emma L Markwell; David A Atchison; James M Pope
Journal:  J Vis       Date:  2011-03-25       Impact factor: 2.240

6.  Accommodation and presbyopia in the human eye. Changes in the anterior segment and crystalline lens with focus.

Authors:  J F Koretz; C A Cook; P L Kaufman
Journal:  Invest Ophthalmol Vis Sci       Date:  1997-03       Impact factor: 4.799

7.  Unified model for accommodative mechanism.

Authors:  D J Coleman
Journal:  Am J Ophthalmol       Date:  1970-06       Impact factor: 5.258

8.  Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second.

Authors:  Benjamin Potsaid; Bernhard Baumann; David Huang; Scott Barry; Alex E Cable; Joel S Schuman; Jay S Duker; James G Fujimoto
Journal:  Opt Express       Date:  2010-09-13       Impact factor: 3.894

9.  Anterior chamber optical coherence tomography study of human natural accommodation in a 19-year-old albino.

Authors:  Georges Baikoff; Eric Lutun; Jay Wei; Caroline Ferraz
Journal:  J Cataract Refract Surg       Date:  2004-03       Impact factor: 3.351

10.  Dual channel dual focus optical coherence tomography for imaging accommodation of the eye.

Authors:  Chuanqing Zhou; Jianhua Wang; Shuliang Jiao
Journal:  Opt Express       Date:  2009-05-25       Impact factor: 3.894

View more
  28 in total

1.  Age-related changes in the anterior segment biometry during accommodation.

Authors:  Yilei Shao; Aizhu Tao; Hong Jiang; Xinjie Mao; Jianguang Zhong; Meixiao Shen; Fan Lu; Zhe Xu; Carol L Karp; Jianhua Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-06       Impact factor: 4.799

2.  Dual band dual focus optical coherence tomography for imaging the whole eye segment.

Authors:  Shanhui Fan; Lin Li; Qian Li; Cuixia Dai; Qiushi Ren; Shuliang Jiao; Chuanqing Zhou
Journal:  Biomed Opt Express       Date:  2015-06-12       Impact factor: 3.732

3.  Non-invasive measurements of the dynamic changes in the ciliary muscle, crystalline lens morphology, and anterior chamber during accommodation with a high-resolution OCT.

Authors:  José J Esteve-Taboada; Alberto Domínguez-Vicent; Daniel Monsálvez-Romín; Antonio J Del Águila-Carrasco; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-04-20       Impact factor: 3.117

4.  Measurement of wavefront aberrations and lens deformation in the accommodated eye with optical coherence tomography-equipped wavefront system.

Authors:  Ji C He; Jianhua Wang
Journal:  Opt Express       Date:  2014-04-21       Impact factor: 3.894

5.  Full anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm.

Authors:  Peng Li; Murray Johnstone; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2014-04       Impact factor: 3.170

6.  Axial biometry of the entire eye using ultra-long scan depth optical coherence tomography.

Authors:  Jianguang Zhong; Yilei Shao; Aizhu Tao; Hong Jiang; Che Liu; Huicheng Zhang; Jianhua Wang
Journal:  Am J Ophthalmol       Date:  2013-10-07       Impact factor: 5.258

7.  Semiautomatic procedure to assess changes in the eye accommodative system.

Authors:  Aikaterini I Moulakaki; Daniel Monsálvez-Romín; Alberto Domínguez-Vicent; José J Esteve-Taboada; Robert Montés-Micó
Journal:  Int Ophthalmol       Date:  2017-10-26       Impact factor: 2.031

8.  Repeatability assessment of anterior segment biometric measurements under accommodative and nonaccommodative conditions using an anterior segment OCT.

Authors:  Noelia Martínez-Albert; Jose J Esteve-Taboada; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-11-02       Impact factor: 3.117

9.  The Relationship Between High-Order Aberration and Anterior Ocular Biometry During Accommodation in Young Healthy Adults.

Authors:  Bilian Ke; Xinjie Mao; Hong Jiang; Jichang He; Che Liu; Min Li; Ying Yuan; Jianhua Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2017-11-01       Impact factor: 4.799

10.  Entire thickness profiles of the epithelium and contact lens in vivo imaged with high-speed and high-resolution optical coherence tomography.

Authors:  Aizhu Tao; Yilei Shao; Hong Jiang; Yufeng Ye; Fan Lu; Meixiao Shen; Dexi Zhu; Jianhua Wang
Journal:  Eye Contact Lens       Date:  2013-09       Impact factor: 2.018

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.