Literature DB >> 20554564

Biaxial biomechanical properties of self-assembly tissue-engineered blood vessels.

Michael T Zaucha1, Robert Gauvin, Francois A Auger, Lucie Germain, Rudolph L Gleason.   

Abstract

Along with insights into the potential for graft success, knowledge of biomechanical properties of small diameter tissue-engineered blood vessel (TEBV) will enable designers to tailor the vessels' mechanical response to closer resemble that of native tissue. Composed of two layers that closely mimic the native media and adventitia, a tissue-engineered vascular adventitia (TEVA) is wrapped around a tissue-engineered vascular media (TEVM) to produce a self-assembled tissue-engineered media/adventia (TEVMA). The current study was undertaken to characterize the biaxial biomechanical properties of TEVM, TEVA and TEVMA under physiological pressures as well as characterize the stress-free reference configuration. It was shown that the TEVA had the greatest compliance over the physiological loading range while the TEVM had the lowest compliance. As expected, compliance of the SA-TEBV fell in between with an average compliance of 2.73 MPa(-1). Data were used to identify material parameters for a microstructurally motivated constitutive model. Identified material parameters for the TEVA and TEVM provided a good fit to experimental data with an average coefficient of determination of 0.918 and 0.868, respectively. These material parameters were used to develop a two-layer predictive model for the response of a TEVMA which fit well with experimental data.

Entities:  

Mesh:

Year:  2010        PMID: 20554564      PMCID: PMC3033022          DOI: 10.1098/rsif.2010.0228

Source DB:  PubMed          Journal:  J R Soc Interface        ISSN: 1742-5662            Impact factor:   4.118


  33 in total

1.  Functional arteries grown in vitro.

Authors:  L E Niklason; J Gao; W M Abbott; K K Hirschi; S Houser; R Marini; R Langer
Journal:  Science       Date:  1999-04-16       Impact factor: 47.728

2.  Tissue reorganization in response to mechanical load increases functionality.

Authors:  Guillaume Grenier; Murielle Rémy-Zolghadri; Danielle Larouche; Robert Gauvin; Kathleen Baker; François Bergeron; Daniel Dupuis; Eve Langelier; Denis Rancourt; François A Auger; Lucie Germain
Journal:  Tissue Eng       Date:  2005 Jan-Feb

3.  Anastomotic intimal hyperplasia: mechanical injury or flow induced.

Authors:  H S Bassiouny; S White; S Glagov; E Choi; D P Giddens; C K Zarins
Journal:  J Vasc Surg       Date:  1992-04       Impact factor: 4.268

4.  Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses.

Authors:  P D Ballyk; C Walsh; J Butany; M Ojha
Journal:  J Biomech       Date:  1998-03       Impact factor: 2.712

5.  Effect of compliance mismatch on vascular graft patency.

Authors:  W M Abbott; J Megerman; J E Hasson; G L'Italien; D F Warnock
Journal:  J Vasc Surg       Date:  1987-02       Impact factor: 4.268

6.  Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts.

Authors:  W Trubel; H Schima; A Moritz; F Raderer; A Windisch; R Ullrich; U Windberger; U Losert; P Polterauer
Journal:  Eur J Vasc Endovasc Surg       Date:  1995-11       Impact factor: 7.069

7.  Theoretical study of the effect of stress-dependent remodeling on arterial geometry under hypertensive conditions.

Authors:  A Rachev
Journal:  J Biomech       Date:  1997-08       Impact factor: 2.712

8.  Tissue-engineered human vascular media with a functional endothelin system.

Authors:  Karina Laflamme; Charles J Roberge; Julie Labonté; Stéphanie Pouliot; Pédro D'Orléans-Juste; François A Auger; Lucie Germain
Journal:  Circulation       Date:  2005-02-01       Impact factor: 29.690

9.  A completely biological tissue-engineered human blood vessel.

Authors:  N L'Heureux; S Pâquet; R Labbé; L Germain; F A Auger
Journal:  FASEB J       Date:  1998-01       Impact factor: 5.191

10.  Stress and strain distribution in hypertensive and normotensive rat aorta considering residual strain.

Authors:  T Matsumoto; K Hayashi
Journal:  J Biomech Eng       Date:  1996-02       Impact factor: 2.097

View more
  3 in total

1.  Comparative analysis of the biaxial mechanical behavior of carotid wall tissue and biological and synthetic materials used for carotid patch angioplasty.

Authors:  Alexey V Kamenskiy; Iraklis I Pipinos; Jason N MacTaggart; Syed A Jaffar Kazmi; Yuris A Dzenis
Journal:  J Biomech Eng       Date:  2011-11       Impact factor: 2.097

2.  Biomechanical Comparison of Glutaraldehyde-Crosslinked Gelatin Fibrinogen Electrospun Scaffolds to Porcine Coronary Arteries.

Authors:  E Tamimi; D C Ardila; D G Haskett; T Doetschman; M J Slepian; R S Kellar; J P Vande Geest
Journal:  J Biomech Eng       Date:  2016-01       Impact factor: 2.097

3.  A Robust Method to Generate Mechanically Anisotropic Vascular Smooth Muscle Cell Sheets for Vascular Tissue Engineering.

Authors:  Daniel E Backman; Bauer L LeSavage; Shivem B Shah; Joyce Y Wong
Journal:  Macromol Biosci       Date:  2017-02-16       Impact factor: 4.979

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.