Literature DB >> 9645537

Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses.

P D Ballyk1, C Walsh, J Butany, M Ojha.   

Abstract

The role of graft-artery compliance mismatch in the development of distal anastomotic intimal hyperplasia (DAIH) is not yet resolved. Although DAIH develops at all surgically created anastomoses, increased compliance mismatch does not lead to greater hyperplasia formation in end-to-end anastomoses, but in end-to-side anastomoses, it leads to a profound increase in hyperplasia. The current study was undertaken to determine whether suture-induced anastomotic stresses could explain these findings. A large strain finite element analysis of vascular wall mechanics was performed to compare the influence of compliance mismatch on intramural stresses in end-to-end versus end-to-side anastomoses. A novel modelling approach was implemented which includes suture-induced stress concentrations. End-to-end and end-to-side graft-artery simulations were executed using (1) artery (compliance = C = 0.44% kPa(-1)), (2) vein (C = 0.33% kPa(-1)), and (3) Dacron (C = 0.14% kPa(-1)) grafts. Residual stresses due to axial tension were included and the anastomoses were statically inflated to 13.3 kPa (100 mmHg). Elevated intramural stresses were found to exist at both the end-to-end and end-to-side graft-artery junctions; however, in the end-to-end anastomosis, the maximum anastomotic stress was not a function of the graft compliance, whereas in the end-to-side anastomosis, the maximum stress was a strong function of graft compliance. For the 45 degree end-to-side geometry considered in this study, the maximum anastomotic stress concentration obtained using a stiff Dacron graft was more than 40% greater than that obtained using a compliant artery graft. In the end-to-end anastomosis, the Dacron graft led to a less than 5% increase in maximum stress over the artery graft. Therefore, increased compliance mismatch increases stresses and promotes DAIH in end-to-side junctions, but, it has little influence on either stresses or DAIH in end-to-end junctions. Thus, the proliferative influence of increased compliance mismatch on suture-line hyperplasia in end-to-side anastomoses can be explained by the resulting increase in intramural stresses. In addition, since high stresses were found in both geometries, elevated suture-line intramural stresses may be an important proliferative stimulus for intimal hyperplasia formation in all vascular reconstructions.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9645537     DOI: 10.1016/s0197-3975(97)00111-5

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  45 in total

1.  Comparative analysis of the biaxial mechanical behavior of carotid wall tissue and biological and synthetic materials used for carotid patch angioplasty.

Authors:  Alexey V Kamenskiy; Iraklis I Pipinos; Jason N MacTaggart; Syed A Jaffar Kazmi; Yuris A Dzenis
Journal:  J Biomech Eng       Date:  2011-11       Impact factor: 2.097

2.  Biaxial biomechanical properties of self-assembly tissue-engineered blood vessels.

Authors:  Michael T Zaucha; Robert Gauvin; Francois A Auger; Lucie Germain; Rudolph L Gleason
Journal:  J R Soc Interface       Date:  2010-06-16       Impact factor: 4.118

3.  Effect of fibroin sponge coating on in vivo performance of knitted silk small diameter vascular grafts.

Authors:  Toshiharu Fukayama; Yusuke Ozai; Haruka Shimokawadoko; Derya Aytemiz; Ryou Tanaka; Noboru Machida; Tetsuo Asakura
Journal:  Organogenesis       Date:  2015       Impact factor: 2.500

4.  A procedure to simulate coronary artery bypass graft surgery.

Authors:  Fernando Cacho; Manuel Doblaré; Gerhard A Holzapfel
Journal:  Med Biol Eng Comput       Date:  2007-08-03       Impact factor: 2.602

5.  Mechanocompatible Polymer-Extracellular-Matrix Composites for Vascular Tissue Engineering.

Authors:  Bin Jiang; Rachel Suen; Jiao-Jing Wang; Zheng J Zhang; Jason A Wertheim; Guillermo A Ameer
Journal:  Adv Healthc Mater       Date:  2016-04-24       Impact factor: 9.933

6.  In Silico Tissue Engineering: A Coupled Agent-Based Finite Element Approach.

Authors:  Maziyar Keshavarzian; Clark A Meyer; Heather N Hayenga
Journal:  Tissue Eng Part C Methods       Date:  2019-09-20       Impact factor: 3.056

7.  Computationally optimizing the compliance of multilayered biomimetic tissue engineered vascular grafts.

Authors:  Ehab Akram Tamimi; Diana Catalina Ardila; Burt D Ensley; Robert S Kellar; Jonathan Vande Geest
Journal:  J Biomech Eng       Date:  2019-02-19       Impact factor: 2.097

8.  Evaluation of endothelialization in the center part of graft using 3 cm vascular grafts implanted in the abdominal aortae of the rat.

Authors:  Toshiharu Fukayama; Yusuke Ozai; Haruka Shimokawatoko; Yusuke Kimura; Derya Aytemiz; Ryou Tanaka; Noboru Machida; Tetsuo Asakura
Journal:  J Artif Organs       Date:  2017-05-12       Impact factor: 1.731

Review 9.  Neointimal hyperplasia associated with synthetic hemodialysis grafts.

Authors:  Li Li; Christi M Terry; Yan-Ting E Shiu; Alfred K Cheung
Journal:  Kidney Int       Date:  2008-07-30       Impact factor: 10.612

10.  Irradiation inhibits vascular anastomotic stenosis in a canine model.

Authors:  Takeshi Saito; Atsushi Iguchi; Koichi Tabayashi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2009-09-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.