Effect of compliance mismatch on vascular graft patency.

W M Abbott, J Megerman, J E Hasson, G L'Italien, D F Warnock.   

Abstract

The hypothesis that a mismatch in compliance between a vascular graft and its host artery is detrimental to graft patency was tested by implanting paired arterial autografts, prepared with differential glutaraldehyde fixation of carotid arteries in the femoral arteries of dogs. These grafts differed only in circumferential compliance: they were 100% (compliant) vs. 40% (stiff) as compliant as the host artery. Their flow surfaces were equivalent, as determined by physicochemical measurements and scanning electron microscopy; both lacked viable cells, as determined by in vitro cell culture. In 14 dogs, eight stiff and two compliant grafts became occluded within 3 months, the latter doing so within 24 hours after their contralateral counterparts. Cumulative patencies were 85% and 37% for compliant and stiff grafts, respectively (p less than 0.05) and 100% and 43%, excluding the two dogs with bilateral graft failures (p less than 0.01). We conclude that even with near optimal flow surfaces, compliance mismatch is deleterious to graft patency.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3102762

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  63 in total

Review 1.  Intravascular stenting: from basic research to clinical application.

Authors:  J C Palmaz
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Sep-Oct       Impact factor: 2.740

2.  Microscopic and immunohistological studies on intimal hyperplasia of the arterially implanted autovein graft and its anastomosis in dogs.

Authors:  D R Shrestha; H Shiroma; Y Kamada; A Kusaba
Journal:  Surg Today       Date:  1992       Impact factor: 2.549

3.  Comparative analysis of the biaxial mechanical behavior of carotid wall tissue and biological and synthetic materials used for carotid patch angioplasty.

Authors:  Alexey V Kamenskiy; Iraklis I Pipinos; Jason N MacTaggart; Syed A Jaffar Kazmi; Yuris A Dzenis
Journal:  J Biomech Eng       Date:  2011-11       Impact factor: 2.097

4.  A novel ovine ex vivo arteriovenous shunt model to test vascular implantability.

Authors:  Haofan Peng; Evan M Schlaich; Sindhu Row; Stelios T Andreadis; Daniel D Swartz
Journal:  Cells Tissues Organs       Date:  2011-10-14       Impact factor: 2.481

5.  Effect of compliance mismatch on flow disturbances in a model of an arterial graft replacement.

Authors:  F Miyawaki; T V How; D Annis
Journal:  Med Biol Eng Comput       Date:  1990-09       Impact factor: 2.602

6.  Biaxial biomechanical properties of self-assembly tissue-engineered blood vessels.

Authors:  Michael T Zaucha; Robert Gauvin; Francois A Auger; Lucie Germain; Rudolph L Gleason
Journal:  J R Soc Interface       Date:  2010-06-16       Impact factor: 4.118

7.  Hair follicle-derived smooth muscle cells and small intestinal submucosa for engineering mechanically robust and vasoreactive vascular media.

Authors:  Hao-Fan Peng; Jin Yu Liu; Stelios T Andreadis; Daniel D Swartz
Journal:  Tissue Eng Part A       Date:  2011-01-16       Impact factor: 3.845

8.  Effects of laser thermal angioplasty on arterial contractions and mechanics.

Authors:  P M Consigny; G P Teitelbaum; G A Gardiner; W D Kerns
Journal:  Cardiovasc Intervent Radiol       Date:  1989 Mar-Apr       Impact factor: 2.740

9.  In vivo determination of human arterial compliance: preliminary investigation of a new technique.

Authors:  M E Hansen; E K Yucel; J Megerman; G J L'Italien; W M Abbott; A C Waltman
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Jan-Feb       Impact factor: 2.740

Review 10.  Biomaterials for vascular tissue engineering.

Authors:  Swathi Ravi; Elliot L Chaikof
Journal:  Regen Med       Date:  2010-01       Impact factor: 3.806

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.