Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts.

W Trubel1, H Schima, A Moritz, F Raderer, A Windisch, R Ullrich, U Windberger, U Losert, P Polterauer.   

Abstract

OBJECTIVE: Compliance and formation of distal anastomotic intimal hyperplasia (DAIH) were investigated in externally stiffened venous grafts of varying calibers.
METHODS: 36 femoropopliteal reconstructions were performed in 18 sheep. The autologous venous grafts were inserted into tubes made of Dacron mesh to achieve compliance-mismatch and lumen adaptation. Compliance was measured by echotracked ultrasonography and profiles of DAIH were generated from histologic sections harvested after 8.3 months. MAIN
RESULTS: The external mesh tube significantly lowered the local compliance of graft and host artery. DAIH appeared extensively in those groups where mesh tube constricted venous grafts met untreated host arteries (p = 0.002). No differences in compliance and DAIH formation were observed when grafts with large and adapted diameters were compared.
CONCLUSIONS: For prevention of DAIH the distal venous graft diameter is not important, while the local compliance of an autologous vein is a predictive factor for DAIH formation and thus long-term patency.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7489209     DOI: 10.1016/s1078-5884(05)80163-7

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  12 in total

1.  Biaxial biomechanical properties of self-assembly tissue-engineered blood vessels.

Authors:  Michael T Zaucha; Robert Gauvin; Francois A Auger; Lucie Germain; Rudolph L Gleason
Journal:  J R Soc Interface       Date:  2010-06-16       Impact factor: 4.118

2.  Construction of tissue-engineered small-diameter vascular grafts in fibrin scaffolds in 30 days.

Authors:  Liqiong Gui; Michael J Boyle; Yishai M Kamin; Angela H Huang; Barry C Starcher; Cheryl A Miller; Michael J Vishnevetsky; Laura E Niklason
Journal:  Tissue Eng Part A       Date:  2014-02-06       Impact factor: 3.845

3.  Computationally optimizing the compliance of multilayered biomimetic tissue engineered vascular grafts.

Authors:  Ehab Akram Tamimi; Diana Catalina Ardila; Burt D Ensley; Robert S Kellar; Jonathan Vande Geest
Journal:  J Biomech Eng       Date:  2019-02-19       Impact factor: 2.097

4.  Hydrostatic pressure independently increases elastin and collagen co-expression in small-diameter engineered arterial constructs.

Authors:  Peter M Crapo; Yadong Wang
Journal:  J Biomed Mater Res A       Date:  2011-01-25       Impact factor: 4.396

Review 5.  Biomaterial-Based Approaches to Address Vein Graft and Hemodialysis Access Failures.

Authors:  Timothy C Boire; Daniel A Balikov; Yunki Lee; Christy M Guth; Joyce Cheung-Flynn; Hak-Joon Sung
Journal:  Macromol Rapid Commun       Date:  2016-09-27       Impact factor: 5.734

6.  3D printing and characterization of a soft and biostable elastomer with high flexibility and strength for biomedical applications.

Authors:  Emilio O Bachtiar; Ozan Erol; Michal Millrod; Runhan Tao; David H Gracias; Lewis H Romer; Sung Hoon Kang
Journal:  J Mech Behav Biomed Mater       Date:  2020-01-23

7.  Pendant allyl crosslinking as a tunable shape memory actuator for vascular applications.

Authors:  Timothy C Boire; Mukesh K Gupta; Angela L Zachman; Sue Hyun Lee; Daniel A Balikov; Kwangho Kim; Leon M Bellan; Hak-Joon Sung
Journal:  Acta Biomater       Date:  2015-06-10       Impact factor: 8.947

8.  Angioplasty Induced Changes in Dialysis Vascular Access Compliance.

Authors:  Yihao Zheng; Brian J Thelen; Nirmala Rajaram; Venkataramu N Krishnamurthy; James Hamilton; Miguel Angel Funes-Lora; Timothy Morgan; Lenar Yessayan; Brandie Bishop; Nickolas Osborne; Peter Henke; Albert J Shih; William F Weitzel
Journal:  Ann Biomed Eng       Date:  2021-08-11       Impact factor: 3.934

9.  In-vivo assessment of a tissue engineered vascular graft computationally optimized for target vessel compliance.

Authors:  Kenneth J Furdella; Shinichi Higuchi; Ali Behrangzade; Kang Kim; William R Wagner; Jonathan P Vande Geest
Journal:  Acta Biomater       Date:  2021-01-20       Impact factor: 8.947

10.  Vascular accesses for haemodialysis in the upper arm cause greater reduction in the carotid-brachial stiffness than those in the forearm: study of gender differences.

Authors:  Daniel Bia; Edmundo I Cabrera-Fischer; Yanina Zócalo; Cintia Galli; Sebastián Graf; Rodolfo Valtuille; Héctor Pérez-Cámpos; María Saldías; Inés Alvarez; Ricardo L Armentano
Journal:  Int J Nephrol       Date:  2012-04-08