Literature DB >> 20532932

Shrinkage of intraperitoneal onlay mesh in sheep: coated polyester mesh versus covered polypropylene mesh.

N B Zinther1, P Wara, H Friis-Andersen.   

Abstract

BACKGROUND: Currently, the laparoscopic placement of intraperitoneal mesh constitutes an acceptable option in the management of ventral hernia. To date, relatively little has been published on the consequences of intra-abdominal placement of a mesh with respect to the decrease of mesh size (shrinkage).
METHODS: In each of 16 sheep, four meshes (dimensions 10 × 10 cm), two based on polyester and two on polypropylene, were placed laparoscopically on intact peritoneum and fixed with either non-absorbable or absorbable tacks. After 3, 6, 12, and 18 months, four animals, respectively, underwent a new laparoscopy with the harvesting of mesh and fascia. Quantitative measurement of the mesh size was performed and expressed as percentage shrinkage. Random core biopsies of mesh and adjacent tissue were obtained and histologically examined.
RESULTS: There was a significant difference of the two meshes with respect to shrinkage at all time points. The coated polyester-based mesh was exposed to more shrinkage compared to the polypropylene mesh covered with anti-adhesive material. Random biopsies at 3 months showed an increased foreign body reaction to the coated polyester mesh.
CONCLUSIONS: This study is the first long-term experimental study on mesh shrinkage after the laparoscopic placement of mesh. The polyester-based mesh induced a more intense foreign body reaction and was exposed to significantly more shrinkage than the covered polypropylene mesh.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20532932     DOI: 10.1007/s10029-010-0682-z

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  18 in total

1.  A comparative study of adhesion formation and abdominal wall ingrowth after laparoscopic ventral hernia repair in a porcine model using multiple types of mesh.

Authors:  J J McGinty; N J Hogle; H McCarthy; D L Fowler
Journal:  Surg Endosc       Date:  2005-03-23       Impact factor: 4.584

2.  Incisional hernia: challenge of re-operations after mesh repair.

Authors:  Joachim Conze; Carsten J Krones; Volker Schumpelick; Uwe Klinge
Journal:  Langenbecks Arch Surg       Date:  2006-09-02       Impact factor: 3.445

3.  A lightweight, partially absorbable mesh (Ultrapro) for endoscopic hernia repair: experimental biocompatibility results obtained with a porcine model.

Authors:  C Schug-Pass; C Tamme; F Sommerer; A Tannapfel; H Lippert; F Köckerling
Journal:  Surg Endosc       Date:  2007-10-26       Impact factor: 4.584

4.  Intraperitoneal onlay mesh: an experimental study of adhesion formation in a sheep model.

Authors:  N B Zinther; P Wara; H Friis-Andersen
Journal:  Hernia       Date:  2010-01-07       Impact factor: 4.739

5.  Evaluation of new prosthetic meshes for ventral hernia repair.

Authors:  J W A Burger; J A Halm; A R Wijsmuller; S ten Raa; J Jeekel
Journal:  Surg Endosc       Date:  2006-07-24       Impact factor: 4.584

6.  Shrinking of polypropylene mesh in vivo: an experimental study in dogs.

Authors:  U Klinge; B Klosterhalfen; M Müller; A P Ottinger; V Schumpelick
Journal:  Eur J Surg       Date:  1998-12

7.  Laparoscopic repair of ventral hernias: nine years' experience with 850 consecutive hernias.

Authors:  B Todd Heniford; Adrian Park; Bruce J Ramshaw; Guy Voeller
Journal:  Ann Surg       Date:  2003-09       Impact factor: 12.969

Review 8.  Recurrences after laparoscopic ventral hernia repair: results and critical review.

Authors:  L J Sánchez; L Bencini; R Moretti
Journal:  Hernia       Date:  2004-01-08       Impact factor: 4.739

9.  Evaluation of sodium carboxymethylcellulose for prevention of adhesions after uterine trauma in ewes.

Authors:  H D Moll; D F Wolfe; J Schumacher; J C Wright
Journal:  Am J Vet Res       Date:  1992-08       Impact factor: 1.156

10.  Prospective histologic evaluation of intra-abdominal prosthetics four months after implantation in a rabbit model.

Authors:  Andrew G Harrell; Yuri W Novitsky; Joseph A Cristiano; Keith S Gersin; H James Norton; Kent W Kercher; B Todd Heniford
Journal:  Surg Endosc       Date:  2007-02-07       Impact factor: 3.453

View more
  15 in total

1.  In vivo MRI visualization of parastomal mesh in a porcine model.

Authors:  J Otto; D Busch; C Klink; A Ciritsis; A Woitok; C Kuhl; U Klinge; U P Neumann; N A Kraemer; J Conze
Journal:  Hernia       Date:  2014-06-10       Impact factor: 4.739

2.  Self-fixing parietex progrip versus the standard sutured prolene mesh in tension-free repair of inguinal hernia: effect on testicular volume and testicular blood flow.

Authors:  Heba El-Komy; Ahmed El-Gendi; Wael Abdel-Salam; Mohamed Elseidy; Elsaid Elkayal
Journal:  Updates Surg       Date:  2018-06-13

3.  Mesh shrinkage depends on mesh properties and anchoring device: an experimental long-term study in sheep.

Authors:  S Harsløf; N Zinther; T Harsløf; C Danielsen; P Wara; H Friis-Andersen
Journal:  Hernia       Date:  2016-08-11       Impact factor: 4.739

4.  Coated meshes for hernia repair provide comparable intraperitoneal adhesion prevention.

Authors:  Marc H F Schreinemacher; Kevin W Y van Barneveld; Rieky E G Dikmans; Marion J J Gijbels; Jan-Willem M Greve; Nicole D Bouvy
Journal:  Surg Endosc       Date:  2013-06-08       Impact factor: 4.584

5.  Conjugation of gold nanoparticles to polypropylene mesh for enhanced biocompatibility.

Authors:  D N Grant; J Benson; M J Cozad; O E Whelove; S L Bachman; B J Ramshaw; D A Grant; S A Grant
Journal:  J Mater Sci Mater Med       Date:  2011-10-07       Impact factor: 3.896

6.  Modified laparoscopic intraperitoneal onlay mesh in complicated inguinal hernia surgery.

Authors:  G M Hyllegaard; H Friis-Andersen
Journal:  Hernia       Date:  2014-04-29       Impact factor: 4.739

7.  Comparative study of shrinkage, inflammatory response and fibroplasia in heavyweight and lightweight meshes.

Authors:  L Zogbi; E N Trindade; M R M Trindade
Journal:  Hernia       Date:  2013-01-24       Impact factor: 4.739

8.  International guidelines for groin hernia management.

Authors: 
Journal:  Hernia       Date:  2018-01-12       Impact factor: 4.739

9.  Long-term outcomes of a randomized controlled trial comparing trans-obturator vaginal mesh with native tissue repair in the treatment of anterior vaginal wall prolapse.

Authors:  Lucie Allègre; Geertje Callewaert; Sandrine Alonso; Arnaud Cornille; Hervé Fernandez; Georges Eglin; Renaud de Tayrac
Journal:  Int Urogynecol J       Date:  2019-09-10       Impact factor: 2.894

10.  DynaMesh® in the repair of laparoscopic ventral hernia: a prospective trial.

Authors:  T Sommer; H Friis-Andersen
Journal:  Hernia       Date:  2013-05-07       Impact factor: 4.739

View more